The AN1582 is a pluggable switch that controls electrical loads connected to mains power using standard type F wall outlets. It can switch all electrical loads up to 3500 W and additionally measure the electrical power taken by this load (in Wh) and meters the electrical energy consumed (in kWh). The device is IP 20 rated and therefore, it only can be used in dry environments. The device is operated either wirelessly using Z-Wave or with a button on the device. A red LED indicates the switching status.
The device can be plugged into every standard outlet (plug type F). Do not locate the Module facing direct sunlight, humid or dusty place. The suitable ambient temperature for the module is 0°C ~ 40°C.
Plug this module into a wall outlet near the load to be controlled. Plug the load into the module and switch the load to the ON position. To turn ON the module and the load plugged into it, press and release the ON/OFF button of the module.
The device is able to switch and measure any electric load up to 3500 W. Any load above 3500 W is considered as overloading. When overloading is detected the device will turn off the load, lock the local button and indicate the status by flashing the LED for 30 sec. Unplugging and replugging the module will reset the module to normal state. The electrical load can be switching using wireless commands and operating the local button. The LED inside the local button will indicate the switching status.
To access the metered and measure electric values a gateway with appropriate visualization is required.
Reset to factory default | Tripple Click the button (same as for inclusion/exlusion) plus pushing the button again within 1 sec and hold it down for 5 sec. |
Inclusion | Inclusion and Exclusion are confirmed by a tripple click of the button of the device. |
Exclusion | Inclusion and Exclusion are confirmed by a tripple click of the button of the device. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
2 | 4 | Pressing button to switch other devices |
1 | 1 | Send Alarm, Switch Report and Meter Report |
This is the time the switching status needs to remain unchanged after a change to cause the device to send out a status message Size: 1 Byte, Default Value: 0a
Setting | Description |
---|---|
00 | Disable |
01 - 78 | 10 * 100 ms = 1 sec |
Enable or Disable the status message function when the local button press changes the switching state Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Disable |
01 | Enable |
The device will report its meter value within the interval set. Set to 0 will disable the autoreporting function. Size: 2 Byte, Default Value: 0003
Setting | Description |
---|---|
0000 | Disabled |
0001 - 0ca8 | Interval = Wert * 10 sec |
Dimensions | 0.0580000x0.1110000x0.0730000 mm |
Weight | 151 gr |
Hardware Platform | ZM3102 |
Device Type | On/Off Power Switch |
Generic Device Class | Binary Switch |
Specific Device Class | Binary Power Switch |
Firmware Version | 01.01 |
Z-Wave Version | 02.40 |
Certification ID | ZC08-09100006 |
Z-Wave Product Id | 0060.0004.0002 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |