Quickstart

This is a On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Press the link key three times within 1.5 seconds to put the unit into inclusion mode.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The On/Off Mini Plug is a Z-WaveTM enabled device which is fully compatible with any Z-WaveTM enabled network. Z-WaveTM enabled devices displaying the Z-WaveTM logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturer‘s Z-WaveTM enabled networks. Inclusion of this unit on other manufacturer‘s Wireless Controller menu allows remote operation of the unit and the connected load.

The On/Off Mini Plug is designed to control the on/off status of appliances load in your house. At 220-240V voltage, this Plug can support up to 1500W resistive.

Installation

Just plug the device into an Type-F outlet

Product Usage

The device will work on Type-F outlets only. It allows remote switching and metering of the load attached.

Reset to factory default 1. Press the link key three times within 1.5 seconds to put the unit into exclusion mode.
2. Within 1 second of step 1, press link key again and hold it until LED is off (about 5 seconds).
Inclusion Press the link key three times within 1.5 seconds to put the unit into inclusion mode.
Exclusion Press the link key three times within 1.5 seconds to put the unit into inclusion mode.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Binary Switch Report,Notification Report,Device Reset Locally Notification,Meter ReportZ-Wave Plus Lifeline
2 4 Basic SetOn/Off control (Button1)

Configuration Parameters

Parameter 1: Set Basic Set Command value


Size: 2 Byte, Default Value: 255

Setting Description
0 - 99 value
255 value

Parameter 2: Set the delaying time to report to Group 1


Size: 1 Byte, Default Value: 3

Setting Description
3 - 25 seconds

Parameter 3: Set whether to remember the last status


Size: 1 Byte, Default Value: 1

Setting Description
0 do not remember
1 remember

Technical Data

Dimensions 0.0515100x0.0775000x0.0515100 mm
Weight 82.94 gr
Hardware Platform SD3502
EAN 4713616113533
IP Class IP 20
Voltage 230 V
Load 1500 W
Device Type On/Off Power Switch
Network Operation Always On Slave
Z-Wave Version 6.51.02
Certification ID ZC10-15090003
Z-Wave Product Id 0x0060.0x0004.0x0007
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeOn/Off Power Switch