Quickstart

This is a On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Press the link key three times within 1.5 seconds to put the unit into inclusion mode.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The Metering Plug is a Z-Wave enabled device which is fully compatible with any Z-Wave enabled network. Z-Wave enabled devices displaying the Z-WaveTM logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturers Z-Wave enabled networks. Inclusion of this unit on other manufacturer as Wireless Controller menu allows remote operation of the unit and the connected load.  The Metering Plug is designed to control the on/off status of appliances load in your house. For metering the unit can detect up to 10485.75kWh and can support wattage, voltage, ampere, and PF detection. The unit can also detect overload upon which the unit will switch off relay and keep LED flashing until power is off and re-applied. At 220-240V voltage, this Plug can support up to 2500W resistive.

Installation

Just plug the device into an Type-F outlet

Product Usage

The device will work on Type-F outlets only. It allows remote switching and metering of the load attached.

Reset to factory default 1. Press the link key three times within 1.5 seconds to put the unit into exclusion mode.
2. Within 1 second of step 1, press link key again and hold it until LED is off (about 5 seconds).
Inclusion Press the link key three times within 1.5 seconds to put the unit into inclusion mode.
Exclusion Press the link key three times within 1.5 seconds to put the unit into exclusion mode.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Lifeline - Binary Switch Report, Notification Report, Device Reset Locally Notification, Meter Report 
2 4 Basic Set, On/Off control (Button1)

Configuration Parameters

Parameter 1: Set Basic Set Command value


Size: 2 Byte, Default Value: 255

Setting Description
0 - 99 value
255 value

Parameter 2: Set the delaying time to report to Group 1


Size: 1 Byte, Default Value: 3

Setting Description
3 - 25 seconds

Parameter 3: Set whether to remember the last status


Size: 1 Byte, Default Value: 1

Setting Description
0 do not remember
1 remember

Parameter 4: Set the interval for wattage auto report


Size: 2 Byte, Default Value: 1

Setting Description
0 does not report automatically
1 - 32767 minutes

Parameter 5: Set the interval for kW/h auto report


Size: 2 Byte, Default Value: 60

Setting Description
0 does not report automatically
1 - 32767 minutes

Parameter 6: Auto report when load surpasses the set value of wattage


Size: 2 Byte, Default Value: 0

Setting Description
0 does not report automatically
1 - 2500 Watt

Parameter 7: Auto report when the change of wattage surpasses the set percentage


Size: 1 Byte, Default Value: 0

Setting Description
0 does not report automatically
1 - 100 %

Technical Data

Weight 84 gr
Hardware Platform SD3502
EAN 0019962012808
IP Class IP 20
Voltage 230 V
Load 2500 W
Device Type On/Off Power Switch
Network Operation Always On Slave
Z-Wave Version 6.51.02
Certification ID ZC10-15080022
Z-Wave Product Id 0x0060.0x0004.0x0006
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeOn/Off Power Switch