Quickstart

This is a Routing Binary Sensor for XXXQFrequencyName. To run this device please insert fresh 1 * CR2450 batteries. To run this device please make sure the internal battery is fully charged.

A tripple click on the tampering switch behind the battery cover within 1.5 seconds will confirm Inclusion and Exclusion. A single click on the same switch will wake up the device and keep it awake for 30 seconds.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This sensor offers information whether a door or window is open or closed. The product consists of a magnetic element and the main unit. One of the parts is mounted on the moving part of the window or of the door. The other part is placed on the frame. The installation can be done with screws or double-sided tape. The HSM02 is a battery-powered device, which is in sleeping mode unless an action is detected. After a programmable sleeping time the device wakes up and sends a status information. After this the unit goes back to sleeping modus. Batteries can be changed without unscrewing the device from the door or frame. The unit will give a visual warning on the device and send a warning to the Z-Wave controller, when batteries need to be replaced. The units send information to a controller or any other associated Z-Wave device. Up to 5 devices can be controlled from this device.

The device needs to be included into a Z-Wave network by a remote control or any other Z-Wave controller. For configuration of certain behaviour a static controller such as a PC with home automation software or a gateway is required.

Installation

1. Ensure that the system properly poweres. Factory default built in a CR2450 battery inside the detector and uses a Mylar film to isolate battery from electric circuit of the detector. Remove the battery Mylar film when ready to let the detector work. If there is no battery inside the detector or need to replace a new battery please insert the battery in 45Ā° angle as below figured

2. Using the adhesive tape to fit the detector on the door or window.

3. Fit the magnet to the moving part of the door/window on the opposite of the detector using the adhesive tape.

4. Ensure that the parallel gap between the magnet and the detector is less than 20 mm and that the matching line on the magnet is pointing towards and aligned with the line on the detector. An alarm condition will be occurred if the gap is larger than 35 mm.

5. Remove the battery cover without pressing the tamper switch on the detector (test mode) and detach or close the magnet from the detector. The LED on the detector will illuminate.

6. After proper installation and test, put the battery cover back to the detector and the detector enters the normal mode.

Reset to factory default 1. Press tamper switch three times withhin 1,5second.
2. Within 1 secound, press and holdthe tamperswitch until LED is off - LED keeps on befor reset function has been compleated.

Inclusion

A tripple Click on the tampering switch behind the battery cover within 1.5 secondsĀ 

Exclusion

A tripple Click on the tampering switch behind the battery cover within 1.5 seconds

NIF

A single click on the tampering switch behind the battery cover will send out a Node Information Frame.

Wakeup

A single click on the tampering switch behind the battery cover will wake up the device and keep it awake for 30 seconds.

Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Alarms and Sensor Status Reports
2 5 Controls devices when sensor triggers

Configuration Parameters

Parameter 1: Level sent on open event

Defines which level to send when sensor triggers
Size: 1 Byte, Default Value: 63

Setting Description
01 - 99 Dimmlevel
99 ON (Binary Switch)

Parameter 2: OFF Delay

Defines the time to wait before the sensor will send OFF command
Size: 1 Byte, Default Value: 1

Setting Description
0 Immediately
1 - 127 Seconds

Technical Data

Dimensions 0.0710000x0.0430000x0.0150000 mm
Weight 39 gr
Hardware Platform ZM3102
EAN 4713616113298
IP Class IP 20
Battery Type 1 * CR2450
Device Type Door/Window Sensor
Generic Device Class Binary Sensor
Specific Device Class Routing Binary Sensor
Firmware Version 01.01
Z-Wave Version 02.4e
Certification ID ZC08-11120005
Z-Wave Product Id 0116.0002.0001
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW