Quickstart

This is a Routing Binary Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged.

Inclusion, Exclusion and wakeup are confirmed by three times quickly hitting the tamper switch on the backside of the case.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This presence detector using PIR (passive infrared receiver) detects the presence of a person in a room. The units send information to a controller or any other associated Z-Wave device. Up to 4 devices can be controlled from this device. The sensor is a battery-powered device, which is in sleeping non-operative mode unless an action is detected. After a programmable sleeping time the device wakes up and sends a status information. After this the unit goes back to sleeping modus. Batteries can be changed without unscrewing the device from the door or frame. The unit will give a visual warning on the device and sends a warning to the Z-Wave controller, when batteries need to be replaced. The unit offers a tampering control and sends an alarm message when tampered.

Installation

1. Release the Sensor from the battery cover by removing the fixing screws.

2. Put the 3 * AA 1.5V batteries in the battery compartment.

3. For mounting use mount plate and the screws.

The detector can be mounted either on a wall or under a ceiling. There is a dedicated lens cover for the two mounting positions which has to be installed.

The recommended position for wall mounting is at the height of 1.8m from the floor. At this height the optimum detection range is up to 10m with coverage range of 110 degrees.

The recommended position for ceiling mounting is at the height of 2.8m from the floor. At this height, the optimum detection range is up to 5m with coverage range of 360 degrees.

Before selecting a position for a Motion Detector the following points should be noted:

Do not position the detector facing a window or direct sunlight. Motion Detectors are not suitable for use in conservatories or draughty areas.

Do not position the detector directly above or facing any source of heat, eg: fires, radiators, boiler etc.

Where possible, mount the detector so that the logical path of an intruder would cut across the fan pattern rather than directly towards the detector.

4. It will take approximately 2 minutes to warm up after battery has been connected. During this period, the detector beeps once every 3 seconds. When a long beep is sounded with red LED turns on steadily for 5 seconds, it implies warm-up procedure is completed and the detector is ready for detection.

Product Usage

Coverage Range Adjustments:

Two types of lens covers are provided for the detector. Wall-lens cover is to be used when the detector is wall-mounted, whereas ceiling-lens cover is to be used when the detector is ceiling-mounted. The coverage range adjustment is only applicable to ceiling-lens cover; choose correct lens cover before mounting. The shading cap for ceiling mounting is composed of 12 segments for limiting the detection coverage, and each segment covers detection angle of 30 degrees. Follow the grooves on the cap, cut the cap to a suitable size and place it onto the ceiling-lens cover. The remaining segments are used for blanking off an undesirable detection area.

By walking into a protected area the detector will now be triggered each time the detector senses movement. The orange LED on the detector will be illuminated and the associated appliances will be activated. For example, siren will be sounded or indication of movement detection will be shown on the controller. It implies that the unit is working properly.

Reset to factory default XXXResetDescription
Inclusion

Make sure that your Z-Wave Controller is in the Inclusion-/Exclusion-Mode. Click three times quickly the tamper switch behind the battery cover to confirm the process.

Exclusion

Make sure that your Z-Wave Controller is in the Inclusion-/Exclusion-Mode. Click three times quickly the tamper switch behind the battery cover to confirm the process.

NIF

Click three times quickly on the tamper switch behind the battery cover or a detected action by the sensor sends a Node Information Frame.

Wakeup

Click three times quickly on the tamper switch behind the battery cover or a detected action by the sensor will wake up the device and keep it awake.

Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Devices controlled by open/close events

Technical Data

Dimensions 0.0850000x0.0850000x0.0480000 mm
Weight 172 gr
EAN 4713616113243
Device Type Routing Binary Sensor
Generic Device Class Binary Sensor
Specific Device Class Routing Binary Sensor
Firmware Version 01.03
Z-Wave Version 02.40
Certification ID ZC08-09100003
Z-Wave Product Id 0086.0002.0004
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeRouting Binary Sensor