This is a
SmartStart or press and release the button on the side.LED blinks slowly light blue when not included.Once included, the LED blinks white when motion is detected for about 5 minutes to test the motion detection area.
Notify caregivers when a loved one does not get up at their usual time or gets up multiple times during the night. Easily installed in a kitchen, bathroom, bedroom or hallway - just plug it in! The wide angle motion sensor detects motion when placed at floor level in a normal wall outlet or at counter height in a kitchen or bath. Never needs batteries!Receive an email or text when motion is detected or the temperature is dangerously low while you are away.Turn on lights and sirens automatically.Save energy by automatically turning off lights in unoccupied rooms or hallways.Set the color LED night light to inform you that your garage door is open, there is a severe weather alert or any indicator you can imagine!Operates as a Z-Wave range extender utilizing fifth generation Z-Wave technology to enhance the reliability and speed of every device on a Z-Wave network. Version 2.0 firmware adds AES-128 security S2 and SmartStart
Reset to factory default | Factory ResetIf the exclusion process above is not working or the controller EZMultiPli was originally joined to is lost or not available, the following process can be used to factory reset EZMultiPli.Press and continue to hold the push button in for about 60 seconds. The LED will blink blue faster and faster and then shift to yellow and continue to blink faster and faster. Once the LED goes out, EZMultiPli is reset to the factory defaults and will blink aqua indicating it is ready to be added to a Z-Wave network. |
Inclusion | SmartStart or press and release the button on the side.LED blinks slowly light blue when not included.Once included, the LED blinks white when motion is detected for about 5 minutes to test the motion detection area. |
Exclusion | When EZMultiPli is first plugged into the wall outlet, the LED should blink an aqua color. This indicates that it is not currently joined (or paired) to a Z-Wave network. If the LED is blinking white each time motion is detected, then it is already joined to a Z-Wave network. If the LED is blinking white you will need to exclude it from the other Z-Wave network before attempting to join a new one.Follow the procedure of the Z-Wave primary controller to begin the exclusion process. Once the primary controller is ready to receive the exclusion command, press and release the push button on the side of EZMultiPli. The primary controller should give an indication that the reset process has completed. EZMultiPlis LED will blink aqua when it is ready to be added to a Z-Wave network. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline.This group supports a single NodeID and is normally assigned to the Z-Wave system controller when EZMultiPli is added to the Z-Wave network. All Notification command class reports (motion detection) are sent to the node assigned to this group. Advanced lighting control should be handled by a home control application based on these reports. |
2 | 4 | This group is used to directly turn lights on or off when motion is detected. Up to four (4) Z-Wave devices can be associated in this group. EZMultiPli will send a BASIC ON command to all devices that are associated in this group. Note that including the NodeID of EZMultiPli in this group will control the LED which will come on when motion is detected and goes off when no motion has been detected for OnTime minutes. |
OnTime sets the number of minutes that the lights stay on when motion has not been detected.A value of 0 is a special mode where the lights are sent a command to turn them on whenever motion is detected. EZMultiPli will NOT turn the lights off in this mode. A motion detection event is sent at most once per minute. Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
0 | Only send an ON every time motion is detected |
1 - 127 | Minutes of No-Motion when an OFF is sent |
OnLevel is the value sent by the Z-Wave BASIC_SET command to all Association Group 2 nodes when motion is detected. A value of 0 will turn the lights off (not recommended).A value between 1 and 99 will set the dim level to between 1% and 99% (99% is full on).A value of -1 will turn the light on which depends on the device but most will set the dim level to the last dim setting. Size: 1 Byte, Default Value: 99
Setting | Description |
---|---|
-1 | Set to previous ON value |
0 | Not Recommended |
1 - 99 | Dim Level to set the associated device to |
A Luminance report is sent to the Lifeline every LiteMin minutes.Luminance values can be obtained at any time by polling. Size: 1 Byte, Default Value: 60
Setting | Description |
---|---|
1 - 255 | Minutes between sensor readings |
A Temperature report is sent to the Lifeline every TempMin minutes.Temperature values can be obtained at any time by polling. Size: 1 Byte, Default Value: 60
Setting | Description |
---|---|
1 - 255 | Minutes between sensor readings |
TempAdj is a twos-complement number that is used to adjust the temperature reading to make it more accurate. The value is in tenths of degree Fahrenheit. The temperature reading can be adjusted by +12.7F to -12.8F. A value of 1 will adjust the temperature reading by +0.1F. A value of -1 will adjust the temperature by -0.1F. A value of 123 will adjust the temperature by +12.3F. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 - 127 | Temperature adjustment in 0.1F |
Hardware Platform | ZM5202 |
Device Type | Notification Sensor |
Network Operation | Always On Slave |
Firmware Version | HW: 3 FW: 2.01 |
Z-Wave Version | 6.81.00 |
Certification ID | ZC10-18015976 |
Z-Wave Product Id | 0x001E.0x0004.0x0001 |
Firmware Updatable | Updatable by Consumer by RF |
Supported Notification Types | Home Security |
Sensors | Air TemperatureLuminanceMotion/No Motion (Binary) |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |