1.Open the cover by turning it counter-clockwise. 2.Place the device within the direct range of your Z-Wave controller.3.Set the main controller in (security/non-security) add mode (see the controllers manual).4.Quickly, three times press the B-button.5.Wait for the adding process to end.6.Successful adding will be confirmed by the Z-Wave controllers message.
FIBARO Motion Sensor is a universal, Z-Wave Plus compatible multi-sensor. This device has a built-in motion sensor, temperature sensor and light sensor. Additionally, through vibrations detection, it may detect tampering attempt or an earthquake. FIBARO Motion Sensor is battery powered, completely wireless, and its casing allows for quick and non-invasive installation on any surface. The eye of the sensor visually indicates motion, temperature level, operating mode or may inform about Z-Wave network range. The device can be used for lighting scenes and presence monitoring systems.
Reset to factory default | 1.Open the cover by turning it counter-clockwise. 2.Press and hold the B-button.3.Wait for visual indicator to glow yellow (2nd menu position).4.Release the B-button.5.Click the B-button to confirm selection.6.After few seconds the device will be reset, which is signalled with the red, fading visual indicator colour.Use reset procedure only if the primary controller is missing or inoperable. |
Inclusion | 1.Open the cover by turning it counter-clockwise. 2.Place the device within the direct range of your Z-Wave controller.3.Set the main controller in (security/non-security) add mode (see the controllers manual).4.Quickly, three times press the B-button.5.Wait for the adding process to end.6.Successful adding will be confirmed by the Z-Wave controllers message. |
Exclusion | 1.Open the cover by turning it counter-clockwise.2.Place the device within the direct range of your Z-Wave controller.3.Set the main controller in remove mode (see the controllers manual).4.Quickly, three times press the B-button.5.Wait for the removing process to end.6.Successful removing will be confirmed by the Z-Wave controllers message. |
NIF | XXXNIF |
Wakeup | The Motion Sensor will wake up at a defined time interval and will always try to communicate with the main controller. There is a possibility to wake up the device manually by clicking the B-button. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline reports the device status and allows for assigning single device only (main controller by default). |
2 | 5 | Motion is assigned to the motion sensor - sends motion detection and alarm cancellation frames to the associated devices. |
3 | 5 | Tamper is assigned to the tamper - sends tamper alarm and alarm cancellation frames to the associated devices. |
4 | 5 | Motion BC is assigned to the motion sensor - sends motion detection and alarm cancellation frames to the associated devices. Provides backward compatibility with controllers not supporting Z-Wave+ protocol. |
5 | 5 | Tamper BC is assigned to the tamper - sends tamper alarm and alarm cancellation frames to the associated devices. Provides backward compatibility with controllers not supporting Z-Wave+ protocol. |
The lower the value, the more sensitive the PIR sensor is. Size: 2 Byte, Default Value: 15
Setting | Description |
---|---|
8 - 255 | sensitivity |
This parameter determines the command frames sent to 2nd association group (assigned to PIR sensor). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | BASIC ON and OFF command frames sent in Basic Command Class |
1 | only the BASIC ON command frame sent in Basic Command Class |
2 | only the BASIC OFF command frame sent in Basic Command Class |
The command frame sent at the moment of motion detection. Further motion detections, during the cancellation time, will not result in sending the association. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 255 | BASIC ON |
The command frame sent at the moment of motion alarm cancellation, after cancellation delay time specified in parameter 6. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 255 | BASIC OFF |
This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. It does not apply to 1st group Lifeline. Size: 1 Byte, Default Value: 15
Setting | Description |
---|---|
0 - 15 | group sent as secure |
PIR sensor is blind (insensitive) to motion after last detection for the amount of time specified in this parameter.Shorter time periods allow to detect motion more frequently, but the battery will be drained faster. Size: 1 Byte, Default Value: 15
Setting | Description |
---|---|
0 - 15 | (0.5-8 seconds, time [s] = 0.5 x (value+1)) |
This parameter determines the change in force acting on the device, that will result in reporting tamper alarm - g-force acceleration. Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
0 | tamper inactive |
1 - 121 | (0.08-2g; every 0.016g) |
Time period after which a tamper alarm will be cancelled in the main controller and associated devices.Any tampering detected during this period will not extend the delay. Size: 2 Byte, Default Value: 30
Setting | Description |
---|---|
1 - 32767 | in seconds |
This parameter determines function of the tamper and sent reports.It is an advanced feature serving much more functions than just detection of tampering. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | tamper only |
1 | tamper and earthquake detector |
2 | tamper and orientation in space |
This parameter allows to disable cancellation of the tamper alarm. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | do not send tamper cancellation report |
1 | send tamper cancellation report |
The parameter determines whether the tamper alarm frame will orwill not be sent in broadcast mode. Alarm frames sent in broadcastmode can be received by all of the devices within range (if they acceptsuch frames), but not repeated by them. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | tamper alarm sent to 3rd association group |
1 | tamper alarm sent in broadcast mode |
The parameter determines whether the backward compatible tamper alarm frame will or will not be sent in broadcast mode. Alarm frames sent in broadcast mode can be received by all of the devices within range (if they accept such frames), but not repeated by them.This parameter provides backward compatibility with controllers not supporting Z-Wave+. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | backward compatible tamper alarm sent to 5th association group |
1 | backward compatible tamper alarm sent in broadcast mode |
This parameter determines the number of moves required for the PIR sensor to report motion. The higher the value, the less sensitive the PIR sensor is.It is not recommended to modify this parameter settings! Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 1 pulse |
1 | 2 pulse |
2 | 3 pulse |
3 | 4 pulse |
Period of time during which the number of moves set in parameter 3 must be detected in order for the PIR sensor to report motion. The higher the value, the more sensitive the PIR sensor is.It is not recommended to modify this parameter setting! Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | 4 seconds |
1 | 8 seconds |
2 | 12 seconds |
3 | 16 seconds |
This parameter determines the change in light intensity level resulting in illuminance report being sent to the main controller. Size: 2 Byte, Default Value: 200
Setting | Description |
---|---|
0 | reports are not sent |
1 - 32767 | (illuminance in lux) |
Time interval between consecutive illuminance reports. The reports are sent even if there is no change in the light intensity. Size: 2 Byte, Default Value: 3600
Setting | Description |
---|---|
0 | periodical reports are not sent |
1 - 32767 | (in seconds) |
Time period after which the motion alarm will be cancelled in the main controller and associated devices.Any motion detected during this period resets the timer. Size: 2 Byte, Default Value: 30
Setting | Description |
---|---|
1 - 32767 | in seconds |
This parameter determines the change in measured temperature that will result in new temperature report being sent to the main controller. Size: 2 Byte, Default Value: 10
Setting | Description |
---|---|
0 | reports are not sent |
1 - 255 | (0.1-25.5C, 0.1C step) |
Time interval between consecutive temperature measurements. The shorter the time, the more frequently the temperature will be measured, but the battery life will shorten. Size: 2 Byte, Default Value: 900
Setting | Description |
---|---|
0 | temperature is not measured |
1 - 32767 | (in seconds) |
Time interval between consecutive temperature reports. The reports are sent even if there is no change in the temperature. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | periodical reports are not sent |
1 - 32767 | (in seconds) |
The value to be added to the actual temperature, measured by the sensor (temperature compensation). Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
-1000 - 1000 | (-100 - 100C, 0.1C, step) |
This parameter determines in which part of day the PIR sensor will be active.This parameter influences only the motion reports and associations.Tamper, light intensity and temperature measurements will be still active, regardless of this parameter settings. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | PIR sensor always active |
1 | PIR sensor active during the day only |
2 | PIR sensor active during the night only |
This parameter determines the way in which visual indicator behaves after motion has been detected. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | LED inactive |
1 - 9 | single long blink at the moment of reporting motion. No other motion will be indicated until alarm is cancelled. |
10 - 18 | single long blink at the moment of reporting motion and one short blink each time the motion is detected again. |
19 - 26 | single long blink at the moment of reporting motion and two short blinks each time the motion is detected again. |
This parameter determines the brightness of the visual LED indicator when indicating motion. Size: 1 Byte, Default Value: 50
Setting | Description |
---|---|
0 | brightness determined by the illuminance(parameters 82 and 83) |
1 - 100 | (1-100%) |
Light intensity level below which brightness of visual indicator is set to 1%. Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 32767 | (in lux) |
Light intensity level above which brightness of visual indicator is set to 100%. Size: 2 Byte, Default Value: 1000
Setting | Description |
---|---|
0 - 32767 | (in lux) |
This parameter is determines minimal temperature that will result in blue visual indicator colour. Relevant only when parameter 80 has been properly configured. Size: 2 Byte, Default Value: 18
Setting | Description |
---|---|
0 - 255 | (in Celsius degree) |
This parameter is determines minimal temperature that will result in red visual indicator colour. Relevant only when parameter 80 has been properly configured. Size: 2 Byte, Default Value: 28
Setting | Description |
---|---|
0 - 255 | (in Celsius degree) |
This parameter allows to enable/disable indicating tamper alarm (flashing white, red and blue) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | tamper alarm is not indicated |
1 | tamper alarm is indicated |
This parameter defines the difference between night and day in terms of light intensity, used in parameter 8. Size: 2 Byte, Default Value: 200
Setting | Description |
---|---|
1 - 32767 | (1-32767 lux) |
Hardware Platform | ZM5202 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 3.03:03.03 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-18015922 |
Z-Wave Product Id | 0x010F.0x0801.0x2001 |
Color | White |
Firmware Updatable | Updatable by Consumer by RF |
Sensors | Air Temperature |
Supported Notification Types | Access Control |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |