Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries of different charging level or different brands.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device. To wakeup the device please perform the following action: Click the button.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline - reports the device status and allows for assigning single device only (main controller by default). |
2 | 5 | CO Alarm - is assigned to the device status - devices in this group will be switched on/off when CO Alarm status changes. |
3 | 5 | CO Alarm - is assigned to the device status - devices in this group will receive notification when CO Alarm status changes. Useful for devices that can trigger alarms. |
4 | 5 | CO Level - is assigned to measured CO level - devices in this group will be switched on/off after exceeding the level of CO concentration specified in parameter 14. |
5 | 5 | Tamper Alarm - is assigned to the tamper - sends tamper alarm and cancellation frames to the associated devices. |
6 | 5 | CO Alarm BC - is assigned to the device status - devices in this group will be switched on/off when CO Alarm status changes. Provides backward compatibility with controllers not supporting Z-Wave+ protocol. |
7 | 5 | Tamper Alarm BC - is assigned to the tamper - sends tamper alarm and alarm cancellation frames to the associated devices. Provides backward compatibility with controllers not supporting Z-Wave+ protocol. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
This parameter allows to set the actions which result in sending notifications to the Z-Wave network controller. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | both actions disabled |
1 | tampering (opened casing) |
2 | exceeding the temperature |
3 | both actions enabled |
This parameter allows to set the actions which result in LED diode indications. This parameter does not apply to the most important actions, such as CO Alarm, Malfunction Alarm and Low Battery Alarm.
NOTE: Parameter values may be combined, e.g. 1+2+4=7 means that all actions will be active.
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | all actions disabled |
1 | tampering (opened casing) |
2 | exceeding the temperature |
3 | lack of Z-Wave range |
This parameter allows to set the actions which result in acoustic signals. This parameter does not apply to the most important actions, such as CO Alarm, Malfunction Alarm and Low Battery Alarm.
NOTE: Parameter values may be combined, e.g. 1+2+4=7 means that all actions will be active.
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | all actions disabled |
1 | tampering (opened casing) |
2 | exceeding the temperature |
3 | lack of Z-Wave range |
Parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. It does not apply to 1st “Lifeline” association group.
Parameter values may be combined, e.g. 1+2=3 means that 2nd & 3rd group are sent as secure.
Size: 1 Byte, Default Value: 63
Setting | Description |
---|---|
1 | 2nd group sent as secure |
2 | 3rd group sent as secure |
4 | 4th group sent as secure |
8 | 5th group sent as secure |
16 | 6th group sent as secure |
32 | 7th group sent as secure |
This parameter defines commands sent to devices associated in 2nd association group (CO Alarm). Values of specified commands may be set in parameters 11 and 12. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 | BASIC ON |
2 | BASIC OFF |
3 | BASIC ON & BASIC OFF |
This parameter defines the value of BASIC ON command sent to devices in 2nd association group after the CO Alarm activation. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 99 | Value |
255 | turn on |
This parameter defines the value of BASIC OFF command sent to devices in 2nd association group after the CO Alarm cancellation. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 99 | Value |
255 | turn on |
This parameter defines commands sent to devices associated in 4th association group (CO Level). Values of specified commands may be set in parameters 16 and 19. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 | BASIC ON |
2 | BASIC OFF |
3 | BASIC ON & BASIC OFF |
This parameter defines the minimum level of CO concentration which exceeding will result in starting the timer set in parameter 15.
NOTE: Parameter 14 value must be at least 5 ppm higher than parameter 17 value.
Size: 2 Byte, Default Value: 40
Setting | Description |
---|---|
20 - 400 | CO concentration level in ppm |
This parameter defines the time during which the level of CO concentration should remain above the value set in parameter 14 to send the BASIC ON command to 4th association group. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | immediate sending of BASIC ON command |
1 - 2880 | (30s - 24h, in 30s steps) |
This parameter defines the value of BASIC ON command sent to devices in 4th association group after exceeding the CO level set in parameter 14 through the time set in parameter 15. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 99 | Value |
255 | turn on |
This parameter defines the maximum level of CO concentration below which falling will result in starting the timer set in parameter 18.
Parameter 17 value must be at least 5 ppm lower than parameter 14 value.
Size: 2 Byte, Default Value: 25
Setting | Description |
---|---|
10 - 400 | CO concentration level in ppm |
This parameter defines the time during which the level of CO concentration should remain below the value set in parameter 17 to send the BASIC OFF command to 4th association group. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | immediate sending of BASIC OFF command |
1 - 2880 | (30s - 24h, in 30s steps) |
This parameter defines the value of BASIC OFF command sent to devices in 4th association group after falling below the CO level set in parameter 17 through the time set in parameter 18. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 99 | Value |
255 | turn on |
Time interval (in seconds) between consecutive reports of temperature (done by built-in temperature sensor). Short time interval means more frequent communication, which results in shortened battery life. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | no periodical reports |
10 - 2880 | (5min - 24h, in 30s steps) |
This parameter defines a minimum change in temperature resulting in a report being sent to the main Z-Wave controller. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
1 - 20 | (0.5°C - 10°C, each 0.5°C) |
This parameter defines the temperature level, which exceeding will result in sending actions set in parameters 2, 3 and 4. Size: 1 Byte, Default Value: 55
Setting | Description |
---|---|
1 - 85 | (1°C - 85°C, each 1°C) |
This parameter activates reporting the value of CO concentration level to the main Z-Wave controller. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | disabled |
1 | enabled |
This parameter defines a minimum change in CO concentration level which results in sending a new value to the main Z-Wave controller. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
2 - 6 | (10 ppm - 30 ppm, each 5 ppm) |
This parameter defines the CO concentration level, which exceeding will result in sending a new value to the main Z-Wave controller, according to parameter 25 settings. Adjusting the value allows to get the accurate data in case of danger and helps to save the battery in normal conditions. Size: 2 Byte, Default Value: 30
Setting | Description |
---|---|
10 - 255 | ppm |
Dimensions | 65x28 mm |
Weight | 41 gr |
Hardware Platform | ZM5202 |
EAN | 5902020528838 |
IP Class | IP 20 |
Battery Type | 1 * CR123A |
Device Type | CO Detector |
Firmware Version | 03.00 |
Z-Wave Version | 04.26 |
Certification ID | ZC10-17055584 |
Z-Wave Product Id | 0x010f.0x1201.0x1000 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |