Inclusion, Exclusion and wakeup are confirmed by triple clicking the Z-Wave button inside the case.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
The Fibaro Flood Sensor will alert you of a threatening flood or a rapid temperature rise or drop and has a wide variety of additional functions. Thanks to its flexible gold telescopic probes the device can even work on uneven surfaces. The Flood Sensor has a built in alarm siren which will help you to react quickly in case of a flood, rapid temperature change or the attempt to tamper with it. Aside from the alarm siren, the device can alert you of a threat using colour displays from the built in RGB diode. In addition to this a tilt sensor will detect tilt and movement over 15 degrees and send out a report to the main controller. The built in temperature sensor can not only be used to serve as a fire alarm sensor, it may also be used to manage an in-floor heating system.
The Input terminal allows you to connect an external probe and install the sensor in any location. The Output terminal allows for a connection to an alarm system. The Sensor will work on 12 or 24V DC or battery.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Reset procedure deletes EPROM"s memory, including all information on the Z-Wave network and the main controller.
Fibaro Flood Sensor"s reset procedure:
1. Make sure the Sensor is powered.
2. Press and hold a TMP button for 15 - 20 seconds. LED indicator glows yellow to confirm entering 4th sub-menu.
3. Release the TMP button.
4. Click the TMP button, once.
5. The LED indicator glowing red and then turning off will confirm a successful reset. Reset completion will be confirmed by an acousic signal, same as at the power source connection.
The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries of different charging level or different brands.
There are two powering modes for the Fibaro Flood Sensor, battery or mains current. By default it"s powered by a factory included battery. In addition it can work with a constant current, after connecting a 12 / 24V DC power supply to +12 and GND terminals. Powering mode configuration is carried out automatically, while a sensor is being included into the Z-Wave network. When battery powered, a Fibaro Flood Sensor communicates with a Z-Wave network main controller periodically. Detected alarms are sent immediately, but configuration parameters and associations settings only at specified wake up intervals, or at a manual wake up (button triple click). In DC powering mode, configuration and associations parameters are sent when necessary, and in addition a sensor serves as a Z-Wave signal repeater.
Switching to a constant current powering mode:
In constant powering mode a sensor may operate without a battery. Installing a battery is recommended though, as it will serve as an emergency power source. When constant power fails, sensor will automatically shift to an emergency mode. All reports, including flood and temperature, will be sent immediately, but it will not be possible to modify the configuration or association settings until constant power returns. If a sensor served as a signal repeater for other Z-Wave devices, in emergency mode signal repeating function will be deactivated.
Note: Fibaro Flood Sensor will automatically exit emergency mode once 12/24 VDC at +12 and GND terminals is detected and the device wakes up after detecting an event, i.e. flood alarm, temperature report, tilt, or manual wake up using button.
The Flood Sensor can also be used with an additional extended wire for the water sensor. Drill a hole into the casing and connect the wire as shown in figure 2.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Make sure that your Z-Wave Controller is in the Inclusion-/Exclusion-Mode. Tripple click the Z-Wave button inside the case to confirm the process.
Make sure that your Z-Wave Controller is in the Inclusion-/Exclusion-Mode. Tripple click the Z-Wave button inside the case to confirm the process.
Fibaro Flood Sensor has two sensors built in - flood and temperature sensors, meaning it"s a multichannel device. In the Z-Wave network"s main controller the Sensor will be shown as two devices.
Through an association Fibaro Flood Sensor may control another Z-Wave network device, e.g. a Dimmer, Relay Switch, Roller Shutter, RGBW Controller, Wall Plug, or a scene.
Z-Wave Range Test
Fibaro Flood Sensor has a built in Z-Wave network range test for the main controller. Follow the instruction to test the main controller"s range:
Z-Wave Range Tester signaling modes:
LED Indicator pulsing green - Fibaro Flood Sensor attempts to directly communicate with the main controller. If the direct communication attempt fails, the sensor will try routed communication, through other devices, which will be signaled with LED Indicator blinking yellow.
LED Indicator glowing green - Fibaro Flood Sensor directly communicating with the main controller.
LED Indicator pulsing yellow - Fibaro Flood Sensor tries to establish routed connection with the main controller, through intermediary devices.
LED Indicator glowing yellow - Fibaro Flood Sensor communicates with the main controller through other, intermediary devices. After two seconds the Sensor will retry to directly connect to the main controller, which will be signaled with the Indicator pulsing green.
LED Indicator pulsing violet - Fibaro Flood Sensor communicates at the range limit. If connection proves successful it will be confirmed with a yellow glow. It"s not recommended to use the sensor at the range limit.
LED Indicator glowing red - Fibaro Flood Sensor unable to connect to the main controller directly or through another Z-Wave network nodes.
The Node Information Frame (NIF) is the business card of a Z-Wave device. It contains information about the device type and the technical capabilities. The inclusion and exclusion of the device is confirmed by sending out a Node Information Frame. Beside this it may be needed for certain network operations to send out a Node Information Frame. To issue a NIF execute the following action:
Tripple click on the Z-Wave button inside the case or a detection by one of the sensors will send a Node Information Frame.
This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device. To wakeup the device please perform the following action:
Tripple click on the Z-Wave button inside the case will wake up the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline - reports the device status and allows for assigning single device only (main controller by default) |
2 | 5 | Flood Control - devices in this group will be switched on or off when flood status changes (done via BASIC SET command frames) |
3 | 5 | Flood Alarm - is assigned to the device status – devices in this group will receive notification about flood detection or cancellation. Useful for devices that can trigger alarms. |
4 | 5 | Tamper Alarm - is assigned to the TMP button and tilt sensor – devices in this group will receive a notification when the sensor is moved or the cover is taken off (which normally holds the button). Useful for devices that can trigger alarms. Functionality can be altered by parameter 74. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Determines time period (in seconds) by which a Flood Sensor will retain the flood state after the flooding itself has ceased. The sensor will keep on reporting flooding to the main controller. This parameter setting does not affect acoustic and visual alarms, which turn off immediately after flooding ceases. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 3600 | in seconds |
Parameter allows for increasing a battery life. Setting changes will not affect the sensor’s communication with the main controller – commands to association groups, alarms and reports will still be sent. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 | acoustic and visual alarms inactive |
1 | acoustic alarm inactive, visual alarm active |
2 | acoustic alarm active, visual alarm inactive |
3 | acoustic and visual alarms active |
Determines the requested “on” level to be sent to devices from 2nd association group upon flood event. The value of 255 allows for turning a device on. In case of a Dimmer it means turning it on with the last memorized state, e.g. Dimmer set to 30% and turned off, turned on again using 255 command is turned on with last state i.e. 30%. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
1 - 99 | requested level |
255 | turn a device on |
This setting decides whether device turn off commands and alarm cancellation notifications will be sent to devices in 2nd and 3rd association groups (respectively)
Setting the parameter’s value to 0 disables sending these two commands to associated devices. This means that these devices WILL NOT be informed when the flooding has ceased. It is still possible to cancel alarms in 3rd association group by choosing second (green) menu position.
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Alarm (flooding) cancellation inactive |
1 | Alarm (flooding) cancellation active |
Time interval (in seconds) between consecutive measurements of battery level and temperature (done by built-in temperature sensor). If the temperature differs from previously reported by a value determined in parameter 12, it will be reported to the Z-Wave controller.
The parameter determines time interval, in seconds, at which a Flood Sensor measures and reports ambient temperature and battery level.
If a temperature value will differ from previously reported by a value determined in parameter 12 (e.g. P12 = 50, i.e. temperatures differ by 0.5°C), new temperature value will be reported. If a battery level changes, the device will report a battery status change – Battery Report.
In battery mode more significant battery level changes will be reported. Short time intervals mean more frequent communication, which results in shortened battery life.
After consecutive FAILED and SUCCESSFUL communication attempts, the Sensor will go to standby mode.
Setting | Description |
---|---|
1 - 65535 | in seconds |
Determines a minimum temperature change value (insensitivity level), resulting in a temperature report being sent to the main controller, according to the Parameter 10 settings. Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
1 - 1000 | each 0.01°C |
The parameter stores a temperature value, below which LED indicator blinks with a colour determined by a Parameter 61 settings. By default the LED indicator blinks blue.
Note: The main controller does not interpret negative numbers as decimals. That’s why read value may be different than entered. Negative numbers are coded in U2 standard.
Size: 2 Byte, Default Value: 1500
Setting | Description |
---|---|
-10000 - +10000 | each 0.01°C |
The parameter stores a temperature value, above which LED indicator blinks with a colour determined by the Parameter 62 settings. By default the LED indicator blinks red.
Note: The main controller does not interpret negative numbers as decimals. That’s why read value may be different than entered. Negative numbers are coded in U2 standard.
Size: 2 Byte, Default Value: 3500
Setting | Description |
---|---|
-10000 - +10000 | each 0.01°C |
Parameter stores RGB colour value.
Note: A main controller interprets colours as a sum of it component colours value. Each colours value is a number from 0 to 255.
Example:
Indicated colour = 65536 * RED value + 256 * GREEN value + BLUE value
Setting | Description |
---|---|
0 - 16777215 | Value |
Parameter stores RGB colour value.
Note: A main controller interprets colours as a sum of it component colours value. Each colours value is a number from 0 to 255.
Example:
Indicated colour = 65536 * RED value + 256 * GREEN value + BLUE value
Setting | Description |
---|---|
0 - 16777215 | Value |
Parameter determines LED indicatoru2019s operation. Set to 0 turns the indicator off, saving a battery life Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | LED indicator doesnt indicate the temperature |
1 | LED indicator indicates the temperature (blink) every Temperature Measurement Interval (Parameter 10, constant current and battery) or Wake Up Interval (battery mode) |
2 | LED indicator indicates the temperature continuously, only in constant power mode |
Parameter stores a temperature value to be added to or deducted from the current temperature measured by internal temperature sensor in order to compensate the difference between air temperature and temperature at the floor level. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
- 10000 - +10000 | Value in °C step 0,01°C |
parameter to device wich sensors send Alarm to 2. association group Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | tamper alarms inactive |
1 | button tamper alarm active |
2 | movement tamper alarm active |
3 | button and movement tampers alarm active |
The device is capable of automatically turning off alarm signalization after a certain amount of time. Long lasting alarm may reduce battery life, when constantly signalized.
The parameter determines time after which alarm will become “quiet” – still active but the device will go into battery saving mode. Visual or acoustic alarm will be reactivated after time specified in the parameter 76. When alarm status ceases, alarm will be turned off immediately.
The value of 0 means visual and acoustic alarms are active indefinitely. In battery power mode the Sensor will never go to sleep which may shorten battery life significantly.
Note: The parameter is ignored when Parameter 2 is set to 0.
Setting | Description |
---|---|
0 | alarms active indefinitely |
1 - 65535 | time in seconds |
Parameter determines a time period after which an alarm will be turned back on (in case it was turned off by parameter 75 setting). It will also resend commands to 2nd and 3rd association groups as if the alarm was detected again.
Note: In case a time period set in parameter 76 is shorter than the one specified in parameter 75, the device will not quiet the alarm, it will remain active.
Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | alarm reactivation inactive |
1 - 65535 | time in seconds |
Allows for turning off the internal flood sensor. Tamper and built in temperature sensor will remain active. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Default flood sensor operation (flood detection, reactions) |
1 | Built in flood sensor TURNED OFF (doesnt change its state in the main controller, doesnut send Alarms and Basic Set frames with flood state changes. Always visible in the main controller as turned off) |
This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. It does not apply to 1st “Lifeline “group. Size: 1 Byte, Default Value: 7
Setting | Description |
---|---|
0 | none of the groups sent as secure |
1 | 2nd group ”Control” sent as secure |
2 | 3rd group ”Alarm” sent as secure |
4 | 4th group „Tamper” sent as secure |
7 | all sent as secure |
Dimensions | 72 x 28 mm |
Weight | 60 gr |
Hardware Platform | ZM5202 |
EAN | 5902020528357 |
IP Class | IP 20 |
Voltage | 12-24V DC |
Battery Type | 1 * CR123A |
Device Type | Flood Sensor |
Firmware Version | 03.02 |
Z-Wave Version | 04.05 |
Certification ID | ZC10-18015963 |
Z-Wave Product Id | 0x010f.0x0b01.0x1003 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |