2) Set the main Z-Wave controller in (security/non-security) add mode (see the controller’s manual).
3) Press any button three times.
4) Wait for the adding process to end.
5) Successful adding will be confirmed by the Z-Wave controller’s message and green LED colour.
FIBARO KeyFob is a Z-Wave Plus compatible, battery-powered, compact remote control. Six buttons allow you to control other devices through the Z-Wave network and run various scenes defined in FIBARO System. Configure actions for one, two, three clicks and holding the button to suit all your needs. Built-in locking system will ensure that unauthorized person will not take control of your home.
Reset to factory default | There are two ways of resetting the device: • Resetting using the menu
1) Press O and – simultaneously. 2) Press Δ or X until LED glows yellow. 3) Press + to confirm. • Resetting on start-up 1) Remove the battery. 2) Hold O and + while inserting the battery. |
Inclusion | Press any button three times. |
Exclusion | 1) Press O and – simultaneously. 2) Press Δ or X until LED glows green. 3) Press + to confirm. |
NIF | XXXNIF |
Wakeup | To wake up the device press O and + simultaneously or use 1st menu position:
1) Press O and – simultaneously. 2) Press Δ or X until LED glows white. 3) Press + to confirm. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline - reports the device status and allows for assigning single device only (main controller by default). |
2 | 5 | Square - On/Off - is assigned to clicking the square button and is used to turn on/off associated devices. |
3 | 5 | Square - Multilevel - is assigned to clicking and holding the square button and is used to turn on/off and change level of associated devices. |
4 | 5 | Circle - On/Off - is assigned to clicking the circle button and is used to turn on/off associated devices. |
5 | 5 | Circle - Multilevel - is assigned to clicking and holding the circle button and is used to turn on/off and change level of associated devices. |
6 | 5 | Cross - On/Off - is assigned to clicking the cross button and is used to turn on/off associated devices. |
7 | 5 | Cross - Multilevel - is assigned to clicking and holding the cross button and is used to turn on/off and change level of associated devices. |
8 | 5 | Triangle - On/Off - is assigned to clicking the triangle button and is used to turn on/off associated devices. |
9 | 5 | Triangle - Multilevel - is assigned to clicking and holding the triangle button and is used to turn on/off and change level of associated devices. |
10 | 5 | Minus - On/Offu201d is assigned to clicking the minus button and is used to turn on/off associated devices. |
11 | 5 | Minus - Multilevel - is assigned to clicking and holding the minus button and is used to turn on/off and change level of associated devices. |
12 | 5 | Plus - On/Off - is assigned to clicking the plus button and is used to turn on/off associated devices. |
13 | 5 | Plus - Multilevel - is assigned to clicking and holding the plus button and is used to turn on/off and change level of associated devices. |
This parameter allows to activate Lock Mode and set up unlocking sequence. Device will lock after time set in parameter 2 or after pressing and holding selected button. See (Lock Mode) on page 9 of the manual for more information. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Lock Mode disabled |
9 - 28086 | unlocking sequence |
This parameter allows to set time that must elapse from the last press of the button to lock the device and locking button. Setting locking button will deactivate associations and scenes for pressing and holding the selected button. This parameter is irrelevant if parameter 1 is set to 0 (Lock Mode disable).See (Lock Mode) on page 9 of the manual for more information. Size: 2 Byte, Default Value: 60
Setting | Description |
---|---|
0 | Lock Mode disabled |
5 - 1791 | calculated value |
This parameter allows to set up sequence that activates scene with ID 7. See (Sequences) in the manual for more information. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 1st sequence disabled |
9 - 28086 | value of sequence |
This parameter allows to set up sequence that activates scene with ID 8. See Sequences in the manual for more information. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 2nd sequence disabled |
9 - 28086 | value of sequence |
This parameter allows to set up sequence that activates scene with ID 9. See Sequences in the manual for more information. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 3rd sequence disabled |
9 - 28086 | value of sequence |
This parameter allows to set up sequence that activates scene with ID 10. See Sequences in the manual for more information. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 4th sequence disabled |
9 - 28086 | value of sequence |
This parameter allows to set up sequence that activates scene with ID 11. See Sequences in the manual for more information. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 5th sequence disabled |
9 - 28086 | value of sequence |
This parameter allows to set up sequence that activates scene with ID 12. See Sequences in the manual for more information. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 6th sequence disabled |
9 - 28086 | value of sequence |
This parameter allows to set time that must elapse from the last press of the button to check if the sequence is valid. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
5 - 30 | 0,5 - 3s time to lock (0,1) |
This parameter allows to choose operating mode for single button associations. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | single press switches state to opposite |
1 | single press switches state to opposite, double press sets to maximum level |
2 | single press turns on, double press turns off |
This parameter allows to set value sent to devices in association group. It will result in turning multilevel devices on with set or last level. Value is irrelevant for simple on/off devices. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
1 - 99 | Forcing level of associated devices |
255 | setting associated devices to the last remembered state or turning them on |
This parameter allows to set value sent to devices in association group. It will result in turning multilevel devices on with set or last level. Value is irrelevant for simple on/off devices. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
1 - 99 | forcing level of associated devices |
255 | setting associated devices to the last remembered state or turning them on |
This parameter allows to set value sent to devices in association group. It will result in turning multilevel devices on with set or last level. Value is irrelevant for simple on/off devices. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
1 - 99 | forcing level of associated devices |
255 | setting associated devices to the last remembered state or turning them on |
This parameter allows to set value sent to devices in association group. It will result in turning multilevel devices on with set or last level. Value is irrelevant for simple on/off devices. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
1 - 99 | forcing level of associated devices |
255 | setting associated devices to the last remembered state or turning them on |
This parameter allows to set value sent to devices in association group. It will result in turning multilevel devices on with set or last level. Value is irrelevant for simple on/off devices. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
1 - 99 | forcing level of associated devices |
255 | setting associated devices to the last remembered state or turning them on |
This parameter allows to set value sent to devices in association group. It will result in turning multilevel devices on with set or last level. Value is irrelevant for simple on/off devices. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
1 - 99 | forcing level of associated devices |
255 | setting associated devices to the last remembered state or turning them on |
This parameter allows to activate paired buttons association mode for Square and Circle buttons. Paired buttons are dependent and association are sent only to Square groups. Circle turns devices on and increases value, Square turns them off and decreases value. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | paired buttons association inactive |
1 | paired buttons association active |
This parameter allows to activate paired buttons association mode for Cross and Triangle buttons. Paired buttons are dependent and association are sent only to Cross groups. Triangle turns devices on and increases value, Cross turns them off and decreases value. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | paired buttons association inactive |
1 | paired buttons association active |
This parameter allows to activate paired buttons association mode for Minus and Plus buttons. Paired buttons are dependent and association are sent only to Minus groups. Plus turns devices on and increases value, Minus turns them off and decreases value. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | paired buttons association inactive |
1 | paired buttons association active |
This parameter determines which actions result in sending assigned scene IDs and attributes to the controller.
NOTE: Parameter values may be combined, e.g. 1+2=3 means that pressing button once or twice will result in sending assigned scene ID.
Size: 1 Byte, Default Value: 9
Setting | Description |
---|---|
1 | Key Pressed 1 time |
2 | Key Pressed 2 times |
4 | Key Pressed 3 times |
8 | Key Held Down & Released |
This parameter determines which actions result in sending assigned scene IDs and attributes to the controller.
NOTE: Parameter values may be combined, e.g. 1+2=3 means that pressing button once or twice will result in sending assigned scene ID.
Size: 1 Byte, Default Value: 9
Setting | Description |
---|---|
1 | Key Pressed 1 time |
2 | Key Pressed 2 times |
4 | Key Pressed 3 times |
8 | Key Held Down & Released |
This parameter determines which actions result in sending assigned scene IDs and attributes to the controller.
NOTE: Parameter values may be combined, e.g. 1+2=3 means that pressing button once or twice will result in sending assigned scene ID.
Size: 1 Byte, Default Value: 9
Setting | Description |
---|---|
1 | Key Pressed 1 time |
2 | Key Pressed 2 times |
4 | Key Pressed 3 times |
8 | Key Held Down & Released |
This parameter determines which actions result in sending assigned scene IDs and attributes to the controller.
NOTE: Parameter values may be combined, e.g. 1+2=3 means that pressing button once or twice will result in sending assigned scene ID.
Size: 1 Byte, Default Value: 9
Setting | Description |
---|---|
1 | Key Pressed 1 time |
2 | Key Pressed 2 times |
4 | Key Pressed 3 times |
8 | Key Held Down & Released |
This parameter determines which actions result in sending assigned scene IDs and attributes to the controller.
NOTE: Parameter values may be combined, e.g. 1+2=3 means that pressing button once or twice will result in sending assigned scene ID.
Size: 1 Byte, Default Value: 9
Setting | Description |
---|---|
1 | Key Pressed 1 time |
2 | Key Pressed 2 times |
4 | Key Pressed 3 times |
8 | Key Held Down & Released |
This parameter determines which actions result in sending assigned scene IDs and attributes to the controller.
NOTE: Parameter values may be combined, e.g. 1+2=3 means that pressing button once or twice will result in sending assigned scene ID.
Size: 1 Byte, Default Value: 9
Setting | Description |
---|---|
1 | Key Pressed 1 time |
2 | Key Pressed 2 times |
4 | Key Pressed 3 times |
8 | Key Held Down & Released |
Parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. It does not apply to 1st (Lifeline) association group.1
NOTE: Parameter 29 values may be combined, e.g. 1+2=3 means that 2nd & 3rd group are sent as secure.
Size: 2 Byte, Default Value: 4095
Setting | Description |
---|---|
1 | 2nd group sent as secure |
2 | 3rd group sent as secure |
4 | 4th group sent as secure |
8 | 5th group sent as secure |
16 | 6th group sent as secure |
32 | 7th group sent as secure |
64 | 8th group sent as secure |
128 | 9th group sent as secure |
256 | 10th group sent as secure |
512 | 11th group sent as secure |
1024 | 12th group sent as secure |
2048 | 13th group sent as secure |
Dimensions | 70 x 38 x 15 mm |
Weight | 30 gr |
Hardware Platform | ZM5101 |
EAN | 5905279987562 |
Battery Type | 1 * CR2450 3.0V |
Device Type | Handheld Controller |
Network Operation | Portable Slave |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-16125346 |
Z-Wave Product Id | 0x010F.0x1001.0x1000 |
Frequency | Europe - 868,4 Mhz |