Quickstart

This is a secure Wall Controller for XXXQFrequencyName. To run this device please insert fresh 1 * ER 14250 1/2 AA 3,6V batteries. To run this device please make sure the internal battery is fully charged.
1. Place the Button within the direct range of your Z-Wave controller.
2. Set the main controller in (security/non-security) add mode (see the controller’s manual).
3. Click the Button at least six times.
4. Wait for the adding process to end.
5. Successful adding will be confirmed by the Z-Wave controller message.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

FIBARO Button is a compact, battery-powered, Z-Wave Plus compatible device. It allows you to control devices through the Z-Wave network and run various scenes defined in FIBARO System.
Different actions may be triggered with one to five clicks or by holding the button down. In Panic Button mode, each press of the button results in triggering the Fibaro Alarm.
With its small design and wireless communication, the FIBARO Button can be conveniently mounted on any surface and in any position or location at home, e.g. beside the bed or under the desk.

Installation

  1. Press and turn the button counter-clockwise to open the casing.
  2. Remove the paper strip underneath the battery.
  3. Press and turn the button clockwise to close the casing.
  4. Place the device within the direct range of your Z-Wave controller.
  5. Set the main controller in (security/non-security) add mode (see the controller’s manual).
  6. Click the button 6 times at least.
  7. Wait for the device to be added into the system, successful adding will be confirmed by the controller.
  8. Install the device in desired location using the attached self-adhesive pad.
  9. Click the button 4 times to wake it up.

Product Usage

Operating the Button

1 click  send action to associated devices (switch on/off by default) and/or trigger a scene
2 clicks  send action to associated devices (switch on maximum level by default) and/or trigger a scene
3 clicks  send action to associated devices (no action by default) and/or trigger a scene
4 clicks  wake the device up and/or trigger a scene
5 clicks  start reset procedure (press and hold for 5s to confirm) and/or trigger a scene
6 or more clicks   learning mode (adding/removing)
Hold  send action to associated devices (start level change up/down) and/or trigger a scene
Release  send action to associated devices (stop level change) and/or trigger a scene

Scene activation

Every action with the Button is send to the main controller with Scene ID equal to 1. Controller recognizes type of action using the attribute assigned to it.

Action Attribute
1 click Key Pressed 1 time
2 clicks Key Pressed 2 times
3 clicks Key Pressed 3 times
4 clicks Key Pressed 4 times
5 clicks Key Pressed 5 times
Hold Key Hold Down
Release Key Released




Reset to factory default 1. Click the Button exactly five times.
2. Press and hold the Button for at least 5 seconds.
Inclusion Click the Button at least six times.
Exclusion Click the Button at least six times.
NIF XXXNIF
Wakeup Click the Button 4 times to wake it up
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Lifeline reports the device status and allows for assigning single device only (main controller by default).
2 5 On/Off is assigned to clicking the button and is used to turn on/off associated devices.
3 5 Dimmer is assigned to holding the button and is used to change level of associated devices.
4 5 Alarm is assigned to clicking and/or holding the button (triggers are defined in parameter 30) and is used to send alarm frames to associated devices.

Configuration Parameters

Parameter 1: Scenes sent to the controller

This parameter determines which actions result in sending scene IDs and attributes assigned to them.
NOTE: Values of parameter 1 may be combined, e.g. 1+2=3 means that scenes will be sent after pressing the button once or twice.

Size: 1 Byte, Default Value: 127

Setting Description
1 Key Pressed 1 time
2 Key Pressed 2 times
4 Key Pressed 3 times
8 Key Pressed 4 times
16 Key Pressed 5 times
32 Key Hold Down
64 Key Released

Parameter 3: Associations in Z-Wave network security mode

This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode.
NOTE: Values of parameter 3 may be combined, e.g. 1+2=3 means that 2nd & 3rd group are sent as secure.

Size: 1 Byte, Default Value: 7

Setting Description
1 2nd group sent as secure
2 3rd group sent as secure
4 4th group sent as secure

Parameter 10: Key Pressed 1 time - command sent to 2nd association group

This parameter defines commands sent to devices associated in 2nd association group after a single click.
Size: 1 Byte, Default Value: 3

Setting Description
0 no action
1 SWITCH ON
2 SWITCH OFF
3 SWITCH ON/OFF - alternately

Parameter 11: Key Pressed 1 time - value of SWITCH ON command sent to 2nd association group

Setting parameters 11, 13, 15, 21, 23 and 25 to appropriate value will result in:
1-99 - forcing level of associated devices
255 - setting associated devices to the last remembered state or turning them on

This parameter defines value of SWITCH ON command sent to devices in 2nd association group after a single click. 1-255- sent value

Size: 2 Byte, Default Value: 255

Setting Description
1 - 99 forcing level of associated devices
255 setting associated devices to the last remembered state or turning them on

Parameter 12: Key Pressed 2 times - command sent to 2nd association group

This parameter defines commands sent to devices associated in 2nd association group after a double click.
Size: 1 Byte, Default Value: 1

Setting Description
0 no action
1 SWITCH ON
2 SWITCH OFF
3 SWITCH ON/OFF - alternately

Parameter 13: Key Pressed 2 times - value of SWITCH ON command sent to 2nd association group

This parameter defines value of SWITCH ON command sent to devices in 2nd association group after a double click.
Size: 2 Byte, Default Value: 99

Setting Description
1 - 99 forcing level of associated devices
255 setting associated devices to the last remembered state or turning them on

Parameter 14: Key Pressed 3 times - command sent to 2nd association group

This parameter defines commands sent to devices associated in 2nd association group after a triple click.0- no action1- SWITCH ON2- SWITCH OFF3- SWITCH ON/OFF - alternately
Size: 1 Byte, Default Value: 0

Setting Description
0 no action
1 SWITCH ON
2 SWITCH OFF
3 SWITCH ON/OFF - alternately

Parameter 15: Key Pressed 3 times - value of SWITCH ON command sent to 2nd association group

This parameter defines value of SWITCH ON command sent to devices in 2nd association group after a triple click.
Size: 2 Byte, Default Value: 255

Setting Description
1 - 99 forcing level of associated devices
255 setting associated devices to the last remembered state or turning them on

Parameter 20: Key Pressed 1 time - command sent to 3rd association group

This parameter defines commands sent to devices associated in 3rd association group after a single click.
Size: 1 Byte, Default Value: 3

Setting Description
0 no action
1 SWITCH ON
2 SWITCH OFF
3 SWITCH ON/OFF - alternately

Parameter 21: Key Pressed 1 time - value of SWITCH ON command sent to 3rd association group

This parameter defines value of SWITCH ON command sent to devices in 3rd association group after a single click.
Size: 2 Byte, Default Value: 255

Setting Description
1 - 99 forcing level of associated devices
255 setting associated devices to the last remembered state or turning them on

Parameter 22: Key Pressed 2 times - command sent to 3rd association group

This parameter defines commands sent to devices associated in 3rd association group after a double click.0 - no action1- SWITCH ON2- SWITCH OFF3- SWITCH ON/OFF - alternately
Size: 1 Byte, Default Value: 1

Setting Description
0 no action
1 SWITCH ON
2 SWITCH OFF
3 SWITCH ON/OFF - alternately

Parameter 23: Key Pressed 2 times - value of SWITCH ON command sent to 3rd association group

This parameter defines value of SWITCH ON command sent to devices in 3rd association group after a double click. 
Size: 2 Byte, Default Value: 99

Setting Description
1 - 99 forcing level of associated devices
255 setting associated devices to the last remembered state or turning them on

Parameter 24: Key Pressed 3 times - command sent to 3rd association group

This parameter defines commands sent to devices associated in 3rd association group after a triple click.
Size: 1 Byte, Default Value: 0

Setting Description
0 no action
1 SWITCH ON
2 SWITCH OFF
3 SWITCH ON/OFF - alternately

Parameter 25: Key Pressed 3 times - value of SWITCH ON command sent to 3rd association group

This parameter defines value of SWITCH ON command sent to devices in 3rd association group after a triple click.
Size: 2 Byte, Default Value: 255

Setting Description
1 - 99 forcing level of associated devices
255 setting associated devices to the last remembered state or turning them on

Parameter 29: Key Held Down - command sent to 3rd association group

This parameter defines commands sent to devices associated in 3rd association group after holding the button down.
Size: 1 Byte, Default Value: 3

Setting Description
0 no action
1 START LEVEL CHANGE UP (brightening)
2 START LEVEL CHANGE DOWN (dimming)
3 START LEVEL CHANGE UP/DOWN (brightening/dimming) - alternately

Parameter 30: Alarm frame triggers

Parameter determines which actions result in sending alarm frames to 4th association group.
NOTE: Values of parameter 30 may be combined, e.g. 1+2=3 means that alarm frames will be sent after pressing the button once or twice.

Size: 1 Byte, Default Value: 127

Setting Description
1 Key Pressed 1 time
2 Key Pressed 2 times
4 Key Pressed 3 times
8 Key Pressed 4 times
16 Key Pressed 5 times
32 Key Held Down
64 Key Released

Technical Data

Dimensions 46x34 mm
Weight 31 gr
Hardware Platform ZM5101
EAN 5902020528968
Battery Type 1 * ER 14250 1/2 AA 3,6V
Device Type Wall Controller
Network Operation Portable Slave
Z-Wave Version 6.51.09
Certification ID ZC10-16105252
Z-Wave Product Id 0x010F.0x0F01.0x1000
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeWall Controller