This is a
1. Place the Button within the direct range of your Z-Wave controller.
2. Set the main controller in (security/non-security) add mode (see the controller’s manual).
3. Click the Button at least six times.
4. Wait for the adding process to end.
5. Successful adding will be confirmed by the Z-Wave controller message.
FIBARO Button is a compact, battery-powered, Z-Wave Plus compatible device. It allows you to control devices through the Z-Wave network and run various scenes defined in FIBARO System.
Different actions may be triggered with one to five clicks or by holding the button down. In Panic Button mode, each press of the button results in triggering the Fibaro Alarm.
With its small design and wireless communication, the FIBARO Button can be conveniently mounted on any surface and in any position or location at home, e.g. beside the bed or under the desk.
1 click | send action to associated devices (switch on/off by default) and/or trigger a scene |
2 clicks | send action to associated devices (switch on maximum level by default) and/or trigger a scene |
3 clicks | send action to associated devices (no action by default) and/or trigger a scene |
4 clicks | wake the device up and/or trigger a scene |
5 clicks | start reset procedure (press and hold for 5s to confirm) and/or trigger a scene |
6 or more clicks | learning mode (adding/removing) |
Hold | send action to associated devices (start level change up/down) and/or trigger a scene |
Release | send action to associated devices (stop level change) and/or trigger a scene |
Every action with the Button is send to the main controller with Scene ID equal to 1. Controller recognizes type of action using the attribute assigned to it.
Action | Attribute |
---|---|
1 click | Key Pressed 1 time |
2 clicks | Key Pressed 2 times |
3 clicks | Key Pressed 3 times |
4 clicks | Key Pressed 4 times |
5 clicks | Key Pressed 5 times |
Hold | Key Hold Down |
Release | Key Released |
Reset to factory default | 1. Click the Button exactly five times. 2. Press and hold the Button for at least 5 seconds. |
Inclusion | Click the Button at least six times. |
Exclusion | Click the Button at least six times. |
NIF | XXXNIF |
Wakeup | Click the Button 4 times to wake it up |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline reports the device status and allows for assigning single device only (main controller by default). |
2 | 5 | On/Off is assigned to clicking the button and is used to turn on/off associated devices. |
3 | 5 | Dimmer is assigned to holding the button and is used to change level of associated devices. |
4 | 5 | Alarm is assigned to clicking and/or holding the button (triggers are defined in parameter 30) and is used to send alarm frames to associated devices. |
This parameter determines which actions result in sending scene IDs and attributes assigned to them.
NOTE: Values of parameter 1 may be combined, e.g. 1+2=3 means that scenes will be sent after pressing the button once or twice.
Size: 1 Byte, Default Value: 127
Setting | Description |
---|---|
1 | Key Pressed 1 time |
2 | Key Pressed 2 times |
4 | Key Pressed 3 times |
8 | Key Pressed 4 times |
16 | Key Pressed 5 times |
32 | Key Hold Down |
64 | Key Released |
This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode.
NOTE: Values of parameter 3 may be combined, e.g. 1+2=3 means that 2nd & 3rd group are sent as secure.
Size: 1 Byte, Default Value: 7
Setting | Description |
---|---|
1 | 2nd group sent as secure |
2 | 3rd group sent as secure |
4 | 4th group sent as secure |
This parameter defines commands sent to devices associated in 2nd association group after a single click. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 | no action |
1 | SWITCH ON |
2 | SWITCH OFF |
3 | SWITCH ON/OFF - alternately |
Setting parameters 11, 13, 15, 21, 23 and 25 to appropriate value will result in:
1-99 - forcing level of associated devices
255 - setting associated devices to the last remembered state or turning them on
This parameter defines value of SWITCH ON command sent to devices in 2nd association group after a single click. 1-255- sent value
Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
1 - 99 | forcing level of associated devices |
255 | setting associated devices to the last remembered state or turning them on |
This parameter defines commands sent to devices associated in 2nd association group after a double click. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | no action |
1 | SWITCH ON |
2 | SWITCH OFF |
3 | SWITCH ON/OFF - alternately |
This parameter defines value of SWITCH ON command sent to devices in 2nd association group after a double click. Size: 2 Byte, Default Value: 99
Setting | Description |
---|---|
1 - 99 | forcing level of associated devices |
255 | setting associated devices to the last remembered state or turning them on |
This parameter defines commands sent to devices associated in 2nd association group after a triple click.0- no action1- SWITCH ON2- SWITCH OFF3- SWITCH ON/OFF - alternately Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | no action |
1 | SWITCH ON |
2 | SWITCH OFF |
3 | SWITCH ON/OFF - alternately |
This parameter defines value of SWITCH ON command sent to devices in 2nd association group after a triple click. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
1 - 99 | forcing level of associated devices |
255 | setting associated devices to the last remembered state or turning them on |
This parameter defines commands sent to devices associated in 3rd association group after a single click. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 | no action |
1 | SWITCH ON |
2 | SWITCH OFF |
3 | SWITCH ON/OFF - alternately |
This parameter defines value of SWITCH ON command sent to devices in 3rd association group after a single click. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
1 - 99 | forcing level of associated devices |
255 | setting associated devices to the last remembered state or turning them on |
This parameter defines commands sent to devices associated in 3rd association group after a double click.0 - no action1- SWITCH ON2- SWITCH OFF3- SWITCH ON/OFF - alternately Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | no action |
1 | SWITCH ON |
2 | SWITCH OFF |
3 | SWITCH ON/OFF - alternately |
This parameter defines value of SWITCH ON command sent to devices in 3rd association group after a double click. Size: 2 Byte, Default Value: 99
Setting | Description |
---|---|
1 - 99 | forcing level of associated devices |
255 | setting associated devices to the last remembered state or turning them on |
This parameter defines commands sent to devices associated in 3rd association group after a triple click. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | no action |
1 | SWITCH ON |
2 | SWITCH OFF |
3 | SWITCH ON/OFF - alternately |
This parameter defines value of SWITCH ON command sent to devices in 3rd association group after a triple click. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
1 - 99 | forcing level of associated devices |
255 | setting associated devices to the last remembered state or turning them on |
This parameter defines commands sent to devices associated in 3rd association group after holding the button down. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 | no action |
1 | START LEVEL CHANGE UP (brightening) |
2 | START LEVEL CHANGE DOWN (dimming) |
3 | START LEVEL CHANGE UP/DOWN (brightening/dimming) - alternately |
Parameter determines which actions result in sending alarm frames to 4th association group.
NOTE: Values of parameter 30 may be combined, e.g. 1+2=3 means that alarm frames will be sent after pressing the button once or twice.
Size: 1 Byte, Default Value: 127
Setting | Description |
---|---|
1 | Key Pressed 1 time |
2 | Key Pressed 2 times |
4 | Key Pressed 3 times |
8 | Key Pressed 4 times |
16 | Key Pressed 5 times |
32 | Key Held Down |
64 | Key Released |
Dimensions | 46x34 mm |
Weight | 31 gr |
Hardware Platform | ZM5101 |
EAN | 5902020528968 |
Battery Type | 1 * ER 14250 1/2 AA 3,6V |
Device Type | Wall Controller |
Network Operation | Portable Slave |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-16105252 |
Z-Wave Product Id | 0x010F.0x0F01.0x1000 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |