Quickstart

This is a Binary Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Quickly, three times press switch no. 1 or the B-button



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

FIBARO Relay Switch is designed to be installed in standard wall switch boxes or anywhere else where it is necessary to control an electric device drawing up to 2500W.
As with all other Actors, FIBARO Relay Switch allows to control connected devices either via the Z-Wave network or via a switch connected directly to it.

Installation

  1. Switch off the mains voltage (disable the fuse)
  2. Open the wall switch box
  3. Connect with one of the diagrams below
  4. Verify correctness of connection
  5. Arrange the device and its antenna in a wall switch box
  6. Close the wall switch box
  7. Turn on the mains voltage
  8. Add the device to the Z-Wave network
Switch connected to the S1 terminal is a master switch. It activates the basic functionality of the device (turning on/off) and starts the learning mode (Add/Remove). The switch connected to the S2 terminal is an optional switch and pushing it without changing the configuration parameters will not affect the status of the device. Functionality of the switches can be reversed by adjusting advanced parameter.


Notes for the diagrams:

  S1 – terminal for switch no. 1 (has the option of entering the device in learning mode)
  S2 – terminal for switch no. 2
  IN – input terminal for load power supply
  Q – output terminal of the device (controlling connected load)
  L – terminal for live lead
  N – terminal for neutral lead  
  B – service button (used to add/remove the device)

Arranging the antenna

  • Locate the antenna as far from metal elements as possible (connecting wires, bracket rings, etc.) in order to prevent interferences.
  • Metal surfaces in the direct vicinity of the antenna (e.g. flush mounted metal boxes, metal door frames) may impair signal reception!
  • Do not cut or shorten the antenna – its length is perfectly matched to the band in which the system operates.

Reset to factory default
  1. Disconnect the power supply
  2. Remove the device from the wall switch box
  3. Connect the power supply
  4. Locate the B-button on the housing
  5. Press and hold the B-button for 3 seconds
  6. After few seconds the device will be reset
Inclusion Quickly, three times press switch no. 1 or the B-button
Exclusion Quickly, three times press switch no. 1 or the B-button
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 is assigned to S1 terminal – sending command frames to the associated devices whenever button connected to S1 terminal is pressed.
2 5 is assigned to S2 terminal – sending command frames to the associated devices whenever button connected to S2 terminal is pressed.
1 3 reports the device status and allows to assign single device only (the main controller by default).

Configuration Parameters

Parameter 1: Switch all function

Allows to activate/deactivate ALL ON / ALL OFF functions.
Size: 1 Byte, Default Value: 255

Setting Description
0 ALL ON is not active, ALL OFF is not active
1 ALL ON is not active, ALL OFF is active
2 ALL ON is active, ALL OFF is not active
255 ALL ON is active, ALL OFF is active

Parameter 3: Override auto off

Auto off relay after specified time, with the possibility of manual override – immediate Off after button push.
Size: 1 Byte, Default Value: 0

Setting Description
0 manual override disabled. After single button push the relay turns on and automatically turns off after specified time.
1 manual override enabled. After single button push the relay turns on and automatically turns off after specified time. Another button push turns the relay off immediately.

Parameter 4: Auto off

Relay will turn off automatically after time specified in this parameter.
Size: 2 Byte, Default Value: 0

Setting Description
0 auto off disabled
1 - 65535 commands are sent when the device is turned on and off

Parameter 6: Command frames sent to 1st association group


Size: 1 Byte, Default Value: 0

Setting Description
0 commands are sent when the device is turned on and off
1 commands are sent when the device is turned off. Turning on the device does not send control commands. Double-clicking button sends ‘turn on’ command, dimmers memorize the last saved level.
2 commands are sent when the device is turned off. Turning on the device does not send control commands. Double-clicking button sends ‘turn on’ command and dimmers are set to 100% brightness.

Parameter 13: Switch and device status relation

Assigns status of the toggle (bistable) switch to status of the device.
Size: 1 Byte, Default Value: 0

Setting Description
0 turn on/off the device on switch status change
1 device status depends on switch status (the device is ON when switch is ON and vice versa)

Parameter 14: Switch type

Parameter defines type of connected switch
Size: 1 Byte, Default Value: 1

Setting Description
0 momentary switch
1 toggle switch

Parameter 15: Dim/shut command sent to 1st association group

Enabling this option allows the user to dim lighting/shut roller by associating Dimmer/Roller Shutter Controller. Hold button to change level or double press to set level to max (only momentary switch).
Size: 1 Byte, Default Value: 0

Setting Description
0 Dimmer/Roller Shutter Controller control is not active
1 Dimmer/Roller Shutter Controller control is active

Parameter 16: Restoring state after power failure

The device can save its state from before a power failure and restore it after power is back.
Size: 1 Byte, Default Value: 1

Setting Description
0 does not save the state after a power failure, it returns to “off” position
1 restores state from before a power failure

Parameter 30: General Alarm

Response to General Alarm command frame.
Size: 1 Byte, Default Value: 3

Setting Description
0 DEACTIVATION – the device does not respond to alarm data frames
1 ALARM RELAY ON – the device turns on after detecting an alarm
2 ALARM RELAY OFF – the device turns off after detecting an alarm
3 ALARM FLASHING – the device periodically changes its status to the opposite, when it detects an alarm within 10 min.

Parameter 32: Smoke, CO and CO2 Alarm

Response to Smoke, CO and CO2 Alarm command frames.
Size: 1 Byte, Default Value: 3

Setting Description
0 DEACTIVATION – the device does not respond to alarm data frames
1 ALARM RELAY ON – the device turns on after detecting an alarm
2 ALARM RELAY OFF – the device turns off after detecting an alarm
3 ALARM FLASHING – the device periodically changes its status to the opposite, when it detects an alarm within 10 min.

Parameter 33: Response to Temperature Alarm command frame.

Response to Temperature Alarm command frame.
Size: 1 Byte, Default Value: 1

Setting Description
0 DEACTIVATION – the device does not respond to alarm data frames
1 ALARM RELAY ON – the device turns on after detecting an alarm
2 ALARM RELAY OFF – the device turns off after detecting an alarm
3 ALARM FLASHING – the device periodically changes its status to the opposite, when it detects an alarm within 10 min.

Parameter 39: Alarm flashing time

Determines how long the flashing will last in case of an alarm.
Size: 2 Byte, Default Value: 600

Setting Description
1 - 65535 time on seconds

Technical Data

Dimensions 42,5 x 38,25 x 20,3mm mm
Weight 26 gr
EAN 5902020528272
IP Class IP IP20
Voltage 230 V
Load 2500 W
Device Type On/Off Power Switch
Generic Device Class Binary Switch
Specific Device Class Binary Power Switch
Z-Wave Version V2.2 - V 2.8
Certification ID ZC08-11080015
Z-Wave Product Id 0x010F.0x0200.0x0102
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeOn/Off Power Switch