Quickstart

This is a Binary Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:

  1. Quickly, three times press switch no. 1 or the B-button



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The In-Wall Double Relay Switch is hereinafter referred to as Fibaro Switch. It is designed to switch on/off devices connected to its terminals using radio waves, controllers and push button directly connected to Fibaro Switch.

The remotely controlled Double Relay Switch of FIBARO system is designed to operate in a wall switch box, wall socket box or in locations where the control of any two electric devices (up to 1.5kW each) is needed. It is also possible to send a signal to any system that is to be integrated with FIBARO system.

Installation

Connecting the device in a manner inconsistent with manual may cause risk to health, life or material damage.

When connecting the device act in accordance with the following rules:

  • Connect only in accordance with one of the diagrams
  • Electrical installation must be protected by overcurrent protection (fuse) of with a value not higher than 10A
  • The device should be installed in a wall switch box compliant with a relevant national safety standards and with depth no less than 60mm
  • Electrical switches used in installation should be compliant with the relevant safety standards
  • Length of wires used to connect the control switch should not exceed 20m

     

Notes for the diagrams:

  S1 – terminal for switch no. 1 (has the option of entering the device in learning mode)
  S2 – terminal for switch no. 2
  IN – input terminal for load power supply
  Q1 – output terminal of the device (controlling first connected load)
  Q2 – output terminal of the device (controlling second connected load)
  L – terminal for live lead
  N – terminal for neutral lead  
  B – service button (used to add/remove the device)

Installation of the device:

  1. Switch off the mains voltage (disable the fuse)
  2. Open the wall switch box
  3. Connect with one of the diagrams below
  4. Verify correctness of connection
  5. Arrange the device and its antenna in a wall switch box
  6. Close the wall switch box
  7. Turn on the mains voltage
  8. Add the device to the Z-Wave network

Switch connected to the S1 terminal is a master switch. It starts the learning mode (Add/Remove). The switch connected to the S1 terminal will switch load connected to the Q1 terminal and switch connected to the S2 terminal will switch load connected to the Q2 terminal. Functionality of the switches can be reversed by adjusting advanced parameter.

Wiring diagrams:

     

Arranging the antenna

  • Locate the antenna as far from metal elements as possible (connecting wires, bracket rings, etc.) in order to prevent interferences.
  • Metal surfaces in the direct vicinity of the antenna (e.g. flush mounted metal boxes, metal door frames) may impair signal reception!
  • Do not cut or shorten the antenna – its length is perfectly matched to the band in which the system operates.

Product Usage

Controlling using an external switch

Momentary switch (after releasing the switch a spring automatically pushes back and disconnects the switch):

  • Turn the load ON/OFF: briefly press the button corresponding to the chosen load

Toggle switch (operates as a two-position switch, it has no spring that would set one position of the switch):

  • Turn the load ON/OFF: change the position of the button corresponding to the chosen load

 ALL ON/ALL OFF

The device responds to commands ALL ON/ALL OFF that may be sent by the Z-Wave controller. ALL ON/ALL OFF commands are usually implemented in the remote controllers using Z-wave protocol, and they are used to issue commands directed to the entire system.

By default, both commands ALL ON and ALL OFF are accepted. Settings may be changed by modifying the value of parameter 1. In this way the user may determine to which commands the device should respond.

Reset to factory default
  • Disconnect the power supply
  • Remove the device from the wall switch box
  • Connect the power supply
  • Locate the B-button on the housing
  • Press and hold the B-button for 3 seconds
  • After few seconds the device will be reset
Inclusion
  1. Quickly, three times press switch no. 1 or the B-button
Exclusion
  1. Quickly, three times press switch no. 1 or the B-button
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 is assigned to S1 terminal – sending command frames to the associated devices whenever button connected to S1 terminal is pressed.
2 5 is assigned to S2 terminal – sending command frames to the associated devices whenever button connected to S2 terminal is pressed.
3 1 Lifeline reports the device status and allows to assign single device only (the main controller by default).

Configuration Parameters

Parameter 1: Switch all function

Allows to activate/deactivate ALL ON / ALL OFF functions.
Size: 1 Byte, Default Value: 255

Setting Description
0 ALL ON is not active, ALL OFF is not active
1 ALL ON is not active, ALL OFF is active
2 ALL ON is active, ALL OFF is not active
255 ALL ON is active, ALL OFF is active

Parameter 3: Override auto off

Auto off relay after specified time, with the possibility of manual override – immediate Off after button push.
Size: 1 Byte, Default Value: 0

Setting Description
0 manual override disabled. After single button push the relay turns on and automatically turns off after specified time.
1 manual override enabled. After single button push the relay turns on and automatically turns off after specified time. Another button push turns the relay off immediately.

Parameter 4: Auto off for relay 1

Relay will turn off automatically after time specified in this parameter.
Size: 2 Byte, Default Value: 0

Setting Description
0 auto off disabled
1 - 65535 (0.1-6553.5s, 0.1 step)

Parameter 5: Auto off for relay 2

Relay will turn off automatically after time specified in this parameter.
Size: 2 Byte, Default Value: 0

Setting Description
0 auto off disabled
1 (0.1-6553.5s, 0.1 step)

Parameter 6: Command frames sent to 1st association group


Size: 1 Byte, Default Value: 0

Setting Description
0 commands are sent when the device is turned on and off
1 commands are sent when the device is turned off. Turning on the device does not send control commands. Double-clicking button sends ‘turn on’ command, dimmers memorize the last saved level.
2 commands are sent when the device is turned off. Turning on the device does not send control commands. Double-clicking button sends ‘turn on’ command and dimmers are set to 100% brightness.

Parameter 7: Command frames sent to 2nd association group


Size: 1 Byte, Default Value: 0

Setting Description
0 commands are sent when the device is turned on and off
1 commands are sent when the device is turned off. Turning on the device does not send control commands. Double-clicking button sends ‘turn on’ command, dimmers memorize the last saved level.
2 commands are sent when the device is turned off. Turning on the device does not send control commands. Double-clicking button sends ‘turn on’ command and dimmers are set to 100% brightness.

Parameter 13: Switch and device status relation

Assigns status of the toggle (bistable) switch to status of the device.
Size: 1 Byte, Default Value: 0

Setting Description
0 turn on/off the device on switch status change
1 device status depends on switch status (the device is ON when switch is ON and vice versa)

Parameter 14: Switch type

Parameter defines type of connected switch
Size: 1 Byte, Default Value: 1

Setting Description
0 momentary switch
1 toggle switch

Parameter 15: Dim/shut command sent to 1st association group

Enabling this option allows the user to dim lighting/shut roller by associating Dimmer/Roller Shutter Controller. Hold button to change level or double press to set level to max (only momentary switch).
Size: 1 Byte, Default Value: 0

Setting Description
0 Dimmer/Roller Shutter Controller control is not active
1 Dimmer/Roller Shutter Controller control is active

Parameter 16: Restoring state after power failure

The device can save its state from before a power failure and restore it after power is back.
Size: 1 Byte, Default Value: 1

Setting Description
1 does not save the state after a power failure, it returns to “off” position
1 restores state from before a power failure

Parameter 30: General Alarm for relay 1

Response to General Alarm command frame.
Size: 1 Byte, Default Value: 3

Setting Description
0 DEACTIVATION – the device does not respond to alarm data frame
1 ALARM RELAY ON – the device turns on after detecting an alarm
2 ALARM RELAY OFF – the device turns off after detecting an alarm
3 ALARM FLASHING – the device periodically changes its status to the opposite, when it detects an alarm within 10 min.

Parameter 31: Flood Alarm for relay 1

Response to Flood Alarm command frame.
Size: 1 Byte, Default Value: 2

Setting Description
0 DEACTIVATION – the device does not respond to alarm data frames
1 ALARM RELAY ON – the device turns on after detecting an alarm
2 ALARM RELAY OFF – the device turns off after detecting an alarm
3 ALARM FLASHING – the device periodically changes its status to the opposite, when it detects an alarm within 10 min.

Parameter 32: Smoke, CO and CO2 Alarm for relay 1

Response to Smoke, CO and CO2 Alarm command frames.
Size: 1 Byte, Default Value: 3

Setting Description
0 DEACTIVATION – the device does not respond to alarm data frames
1 ALARM RELAY ON – the device turns on after detecting an alarm
2 ALARM RELAY OFF – the device turns off after detecting an alarm
3 ALARM FLASHING – the device periodically changes its status to the opposite, when it detects an alarm within 10 min.

Parameter 33: Temperature Alarm for relay 1

Response to Temperature Alarm command frame.
Size: 1 Byte, Default Value: 1

Setting Description
0 DEACTIVATION – the device does not respond to alarm data frames
1 ALARM RELAY ON – the device turns on after detecting an alarm
2 ALARM RELAY OFF – the device turns off after detecting an alarm
3 ALARM FLASHING – the device periodically changes its status to the opposite, when it detects an alarm within 10 min.

Parameter 39: Alarm flashing time

Determines how long the flashing will last in case of an alarm.
Size: 2 Byte, Default Value: 600

Setting Description
1 - 65535 time on seconds

Parameter 40: General Alarm for relay 2

Response to General Alarm command frame.
Size: 3 Byte, Default Value: 1

Setting Description
0 DEACTIVATION – the device does not respond to alarm data frames
1 ALARM RELAY ON – the device turns on after detecting an alarm
2 ALARM RELAY OFF – the device turns off after detecting an alarm
3 ALARM FLASHING – the device periodically changes its status to the opposite, when it detects an alarm within 10 min.

Parameter : Flood Alarm for relay 2

Response to Flood Alarm command frame.
Size: 2 Byte, Default Value: 1

Setting Description
0 DEACTIVATION – the device does not respond to alarm data frames
1 ALARM RELAY ON – the device turns on after detecting an alarm
2 ALARM RELAY OFF – the device turns off after detecting an alarm
3 ALARM FLASHING – the device periodically changes its status to the opposite, when it detects an alarm within 10 min.

Parameter 42: Smoke, CO and CO2 Alarm for relay 2

Response to Smoke, CO and CO2 Alarm command frames.
Size: 1 Byte, Default Value: 3

Setting Description
0 DEACTIVATION – the device does not respond to alarm data frames
1 ALARM RELAY ON – the device turns on after detecting an alarm
2 ALARM RELAY OFF – the device turns off after detecting an alarm
3 ALARM FLASHING – the device periodically changes its status to the opposite, when it detects an alarm within 10 min.

Parameter 43: Temperature Alarm for relay 2

Response to Temperature Alarm command frame.
Size: 1 Byte, Default Value: 1

Setting Description
0 DEACTIVATION – the device does not respond to alarm data frames
1 ALARM RELAY ON – the device turns on after detecting an alarm
2 ALARM RELAY OFF – the device turns off after detecting an alarm
3 ALARM FLASHING – the device periodically changes its status to the opposite, when it detects an alarm within 10 min.

Technical Data

Dimensions 37x42x16 mm
Weight 26 gr
Hardware Platform ZM3102
EAN 5902020528289
IP Class IP 20
Voltage 230 V
Load 2 x 1500W
Device Type On/Off Power Switch
Generic Device Class Binary Switch
Specific Device Class Binary Power Switch
Z-Wave Version 4.52
Certification ID ZC08-11070003
Z-Wave Product Id 0x010F.0x0200.0x0102
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeOn/Off Power Switch