Quickstart

This is a secure Binary Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Fibaro Wall Plug is a universal, Z-Wave compatible, relay switch in the form of a socket adapter. The Plug may be used to operate any device up to 2,500W power output. The Plug features power consumption measuring and uses a crystal LED ring to visualize the current load by color changing illumination. Fibaro Wall Plug may be operated using the service button located on its casing, or via any Z-Wave compatible controller.

Installation

  1. Insert device into a socket.
  2. Add device into the Z-Wave network if necessary.
  3. Connect load to the Plug, making sure it does not exceed 2500W.
  4. Set the connected device switch to ON. 
  5. To turn on connected device manually turn on the Plug using B button. (Alternative to remote control via Z-Wave controller) Once the Plug is turned on, LED ring will glow. 
  6. Current power load is visualized with LED ring color.
  7. Press B button to turn off the Plug manually. 
  8. Once the Plug is turned off, LED ring illumination is turned off as well. 

Product Usage

Range test

FIBARO Wall Plug has a built-in Z-Wave network main controller’s range tester.

NOTE: To make Z-Wave range test possible, the device must be added to the Z-Wave controller. Testing may stress the network, so it is recommended to perform the test only in special cases.

Follow the below instructions to test the main controller’s range:

  1. Insert the device into a socket
  2. Press and hold the B-button until the visual indicator glows violet
  3. Release the B-button
  4. Press the B-button again, briefly
  5. Visual indicator will indicate the Z-Wave network’s range (range signalling modes described below)
  6. To exit Z-Wave range test, press the B-button briefly

Z-Wave range tester signalling modes:

  • Visual indicator pulsing green – Wall Plug attempts to establish a direct communication with the main controller. If a direct communication attempt fails, the device will try to establish a routed communication, through other modules, which will be signalled by visual indicator pulsing yellow.
  • Visual indicator glowing green – Wall Plug communicates with the main controller directly.
  • Visual indicator pulsing yellow – Wall Plug tries to establish a routed communication with the main controller through other modules (repeaters).
  • Visual indicator glowing yellow – Wall Plug communicates with the main controller through the other modules. After 2 seconds the device will retry to establish a direct communication with the main controller, which will be signalled with visual indicator pulsing green.
  • Visual indicator pulsing violet – Wall Plug does communicate at the maximum distance of the Z-Wave network. If connection proves successful it will be confirmed with a yellow glow. It is not recommended to use the device at the range limit.
  • Visual indicator glowing red – Wall Plug is not able to connect to the main controller directly or through another Z-Wave network device (repeater).

Visual LED indicator

FIBARO Wall Plug is equipped with a colour changing LED ring, signalling operating status and connected devices power. Colours shown are those of a RGB scheme. In addition, the LED ring signals Plugs range in relation to the Z-Wave networks main controller and overheating protection activation

Visual indicator signalling modes:

  • Wall Plug status (On/Off) signalled with a color defined by relevant parameter settings (see parameters no. 60, 61, 62).
  • Alarm status signalled according to parameters 63 settings.
  • Energy meter reset signalled by double, green blink.
  • Once inserted to mains socket, LED ring signals Z-Wave network inclusion status. Single green blink means it’s included. Single red blink means Plug has not been included in the Z-Wave network.
  • Blinking yellow means memory write during software update process.
  • Alternating blinking, yellow / red, signals overheating warning (overload).

 Menu

FIBARO Wall Plug has a MENU with each position indicated by the specified LED ring indicator colour.

In order to enter the menu press the B-button and hold for at least 2 seconds. While the B-button is still pressed, LED ring indicator colour will change in the following sequence:

  • WHITE – activate/deactivate LED ring indications
  • GREEN – reset the energy consumption data memory
  • VIOLET – initiate the Z-Wave network range test
  • YELLOW – reset the Wall Plug to factory defaults

Release the B-button to choose the desired function and confirm your choice with the B-button click.

Reset to factory default
  • Insert the Plug into a socket.
  • Press and hold the B button for 15 - 20 seconds until LED ring glows yellow
  • Release the B button. 
  • Press the B button, briefly.
Inclusion
  • Triple click the B button
Exclusion Triple click the B button
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Is assigned to the device status – sending command frames to the associated devices whenever the Wall Plug is turned ON or OFF via B-button.
2 5  is assigned to the measured active power – sending command frames to the associated devices depending on the measured load (configured via advanced parameters 50, 51 and 52)
3 1 Reports the device status and allows to assign single device only (the main controller by default).

Configuration Parameters

Parameter 1: Always On function

Once activated, Wall Plug will keep a connected device constantly ON, will stop reacting to alarm frames and B-button push.

“Always on” function turns the Plug into a power and energy meter. Also, connected device will not be turned off upon receiving an alarm frame from another Z-Wave device (parameter 35 will be ignored).

In “Always on” mode, connected device may be turned off only after user defined power has been exceeded (parameter 70). In such a case, connected device can be turned on again by pushing the B-button or sending a control frame. By default, overload protection is inactive.


Size: 1 Byte, Default Value: 1

Setting Description
0 function activated
1 function inactive

Parameter 16: Remember device status after power failure

Define how will the Plug react after the power supply is back on.
Size: 1 Byte, Default Value: 1

Setting Description
0 Wall Plug does not memorize its state after a power failure. Connected device will be off after the power supply is reconnected.
1 Wall Plug memorizes its state after a power failure.

Parameter 34: Reaction to alarms

Z-Wave network alarm will be signalled by LED ring according to the parameter 63 settings. Blinking in Red/Blue/White is a default setting. 
Connected device state will be changed according to the parameter 35 settings. By default, connected device state will remain unchanged.
Wall Plug will be signaling an alarm through the time period specified in the parameter 39 (10 minutes by default), unless the alarm is cancelled earlier. In addition Wall Plug may exit the alarm mode after the B-button has been pressed and held for 2 – 5 seconds.

Define Z-Wave network alarms to which the Wall Plug will respond.
Note: If Always On function is active (parameter 1), this parameters settings are ignored.

Size: 1 Byte, Default Value: 63

Setting Description
0 - 63 Calculate value of the parameter: 1 - general alarm 2 - smoke alarm 4 - CO alarm 8 - CO2 alarm 16 - high temperature alarm 32 - flood alarm

Parameter 35: Wall Plugs response to alarm frames

Parameter defines how the Wall Plug will respond to alarms (device’s status change)
Size: 1 Byte, Default Value: 0

Setting Description
0 no reaction
1 turn on connected device. LED ring signals an alarm through defined time period (parameter 39) or untill the alarm is cancelled
2 turn off connected device. LED ring signals an alarm through defined time period (parameter 39) or untill the alarm is cancelled
3 cyclically change device state, each 1second. In alarm mode Wall Plug does not report status change, power changes, ignores alarm frames. After the defined time period has passed (parameter 39) or after the alarm cancellation, connected device is set to the previous state

Parameter 39: Alarm duration

Wall Plug’s alarm mode duration. If a device sending an alarm frame through the Z-Wave network sets alarm duration as well, this parameter’s settings are ignored.
Size: 2 Byte, Default Value: 600

Setting Description
1 - 65535 in seconds

Parameter 40: Immediate power report

Reports on power load, sent to the main controller. Default settings of below parameters are chosen in such a way that instantaneous power load is shown without blocking the Z-Wave network in the process. Default settings are good for most of the devices. In specific cases it may be necessary to modify default settings in order to optimize Z-Wave network’s use.
Fibaro Wall Plug reports the power load with specified frequency. Below configuration parameters allow to specify how and how frequently power load will be reported.

Parameter defines by how much power load must change, in percents, to be reported to the main controller, with the highest priority in the Z-Wave network. By default, Wall Plug immediately sends power report if the power load changes by 80%. Value of 100 (%) means the reports are turned off.
NOTE: In extreme cases, reports may be sent every second if rapid and significant power load changes occur. Frequent reporting may overload the Z-Wave network so these parameters settings should reflect significant changes in power load only.

Size: 1 Byte, Default Value: 80

Setting Description
1 - 100 in %

Parameter 42: Standard power load reporting

Parameter defines by how much power load must change, in percents, to be reported to the main controller. By default, Wall Plug sends power report if the power load changes by 15%.
By default such changes in power load may be reported up to 5 times per 30 seconds. Wall Plug sends 5 reports during time period specified in paramater 43.

Size: 1 Byte, Default Value: 15

Setting Description
0 reports are turned off
1 - 99 in %

Parameter 43: Power reporting frequency

This parameter defines how frequently standard power reports (parameter 42) will be sent. By default Wall Plug sends up to 5 reports each 30 seconds, provided the power load changes by 15%.
Size: 1 Byte, Default Value: 30

Setting Description
1 - 254 time in seconds
255 reports will be sent only as a result of parameter 47 settings or in case of polling

Parameter 45: Reporting changes in energy consumed by controlled devices

New, reported energy value is calculated based on last reported value.
Size: 1 Byte, Default Value: 10

Setting Description
1 - 254 0.01-2.54kWh, step 0.01kWh
255 changes in consumed energy will not be reported, reports will be sent only in case of polling

Parameter 47: Time period between reports on power load and energy consumption

Parameter defines time period between reports sent when changes in power load have not been recorded. By default, if power load changes have not been recorded, reports are sent every hour.
Size: 2 Byte, Default Value: 3600

Setting Description
1 - 65534 in seconds
65535 no periodic reports. Reports will be sent only in case of power load / energy consumption changes (parameters 40, 42, 43,45) or in case of polling.

Parameter 49: Metering energy consumed by the Wall Plug itself

This parameter determines whether energy metering should include the amount of energy consumed by the Wall Plug itself. Results are being added to energy consumed by controlled device.
Size: 1 Byte, Default Value: 0

Setting Description
0 function inactive
1 function active

Parameter 50: DOWN value

Status of devices added to 2nd Association Group may depend on power consumed by the connected device. For example, turning on the TV controlled by the Plug will turn off the lights in the room. 
User defines two thresholds: UP and DOWN, and then defines the reaction to them being exceeded (parameter 52).

Lower power threshold, used in parameter 52.


Size: 2 Byte, Default Value: 300

Setting Description
0 - 25000 0-2500W, step 0.1W

Parameter 51: UP value

Upper power threshold, used in parameter 52
Size: 2 Byte, Default Value: 500

Setting Description
0 - 25000 0.1-2500W, step 0.1W

Parameter 52: Action in case of exceeding defined power values (parameters 50 and 51)

Parameter deifines the way 2nd association group devices are controlled, depending on the current power load.
Size: 1 Byte, Default Value: 6

Setting Description
0 function inactive
1 turn the associated devices on, once the power drops below DOWN value (parameter 50)
2 turn the associated devices off, once the power drops below DOWN value (parameter 50)
3 turn the associated devices on, once the power rises above UP value (parameter 51)
4 turn the associated devices off, once the power rises above UP value (parameter 51)
5 1 and 4 combined. Turn the associated devices on, once the power drops below DOWN value (parameter 50). Turn the associated devices off, once the power rises above UP value (parameter 51)
6 2 and 3 combined. Turn the associated devices off, once the power drops below DOWN value (parameter 50). Turn the associated devices on, once the power rises above UP value (parameter 51)

Parameter 60: Power load, which when exceeded, makes the LED ring flash violet

Function is active only when parameter 61 is set to 0 or 1.
Size: 2 Byte, Default Value: 25000

Setting Description
1000 - 32000 100-3200W, step 0.1W

Parameter 61: LED ring illumination colour when controlled device is on


Size: 1 Byte, Default Value: 1

Setting Description
0 LED ring illumination colour changes in predefined steps, depending on power consumption changes
1 LED ring illumination colour changes continuously, using full spectrum of available colorus, depending on power consumption changes
2 white illumination
3 red illumination
4 green illumination
5 blue illumination
6 yellow illumination
7 cyan (Greenish blue) illumination
8 magenta (Purplish red) illumination
9 illumination turned off completely

Parameter 62: LED ring illumination color when controlled device is off


Size: 1 Byte, Default Value: 8

Setting Description
0 LED ring is illuminated with a color corresponding to the last measured power, before the controlled device was turned off
1 white illumination
2 red illumination
3 green illumination
4 blue illumination
5 yellow illumination
6 cyan (Greenish blue) illumination
7 magenta (Purplish red) illumination
8 illumination turned off completely

Parameter 63: LED ring illumination colour at the Z-Wave network alarm detection


Size: 1 Byte, Default Value: 1

Setting Description
0 no change in colour, LED ring illumination colour determined by parameters 61 or 62 settings
1 LED ring flashes red / blue / white
2 white illumination
3 red illumination
4 green illumination
5 blue illumination
6 yellow illumination
7 cyan (Greenish blue) illumination
8 magenta (Purplish red) illumination
9 illumination turned off completely

Parameter 70: Oveload safety switch

This function allows for turning off the controlled device in case of exceeding the defined power. Controlled device will be turned off even if “always on” function is active (parameter 1).
Controlled device can be turned back on via B-button or sending a control frame. By default this function is inactive.

NOTE: This functionality is not an overload safety protection nor a short circuit protection. Circuit needs additional short circuit and overload protection.

 

Value higher than 32000 (3200W) turns the overload safety switch off, i.e. this functionality is turned off by default.
Size: 2 Byte, Default Value: 65535

Setting Description
10 - 65535 1-6553.5W, step 0.1W

Technical Data

Dimensions 43x43x65 mm
Weight 55 gr
Hardware Platform ZM5202
EAN 5902020528630
IP Class IP 20
Voltage 230 V
Load 2500 W
Device Type On/Off Power Switch
Generic Device Class Binary Switch
Specific Device Class Binary Power Switch
Firmware Version 03.02
Z-Wave Version 04.05
Certification ID ZC10-16035016
Z-Wave Product Id 0x010f.0x0602.0x1001
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeOn/Off Power Switch