Quickstart

This is a Routing Binary Sensor for XXXQFrequencyName. To run this device please connect it to your mains power supply.

Tripple Click the "B" Button on the device confirms the inclusion and exclusion.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This universal Z-Wave sensor is designed to improve electronic devices with on/off switches or analog outputs by connecting them to a wireless Z-Wave network. The device can service two binary inputs and up to 4 DS18B20 temperature probes. The device can also control up to two external digital inputs (up to 150 mA). The sensor is designed to be included into the housing of another device and to be powered by this device with an input power between 9 and 30 V DC.

Installation

Explanation of the cable markings

  • P (POWER), power supply cable, red
  • GND (Ground), ground cable, blue
  • OUT1, output No 1, assigned to input IN1
  • OUT2, output No 2, assigned to input IN2
  • TP (TEMP_POWER), power supply cable to the DS18B20 temperature sensor, brown
  • TD (TEMP_DATA), signal cable to the DS18B20 temperature sensors, white
  • ANT, antenna, black
  • OUT1, output no 1 - assigned to input IN1
  • OUT2, output no 2 - assigned to input IN2
  • B, maintenance button

The external temperature sensors DS18B20 are connected to the device as shown on this picture. The subsequent image shows how to connect such an external switch or an external sensor to the terminals.

Reset to factory default Disconnect and reconnect the device from the power supply while folding down the "B" button for 10 seconds. After the next reconnect of the power the device is back in factory default.
Inclusion

Tripple Click the "B" Button on the device confirms inclusion and exclusion.

Exclusion

Tripple Click the "B" Button on the device confirms inclusion and exclusion.

NIF

Tripple Click the

Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Input IN1
2 5 Input IN2
3 5 reports device status

Configuration Parameters

Parameter 1: Input 1 Alarm Delay

defines the delay from triggering Input 1 to sending an alarm. Removing Alarm condition will cancel alarm
Size: 2 Byte, Default Value: 0

Setting Description
1 - 65535 seconds

Parameter 2: Input 2 Alarm Delay

defines the delay from triggering Input 2 to sending an alarm. Removing Alarm condition will cancel alarm
Size: 2 Byte, Default Value: 0

Setting Description
1 - 65535 seconds

Parameter 3: Type of Input 1


Size: 1 Byte, Default Value: 1

Setting Description
0 INPUT_NO (Normal Open)
1 INPUT_NC (Normal Close)
2 INPUT_MONOSTABLE (Monostabil)
3 INPUT_BISTABLE (bistabil)

Parameter 4: Type of Input 2


Size: 1 Byte, Default Value: 1

Setting Description
0 INPUT_NO (Normal Open)
1 INPUT_NC (Normal Close)
2 INPUT_MONOSTABLE (Monostabil)
3 INPUT_BISTABLE (bistabil)

Parameter 5: Type of control frame activated via IN input 1

The parameter allows you to specify the type of an alarm frame for Input 1
Size: 1 Byte, Default Value: 255

Setting Description
0 ALARM GENERIC frame
1 ALARM SMOKE frame
2 ALARM CO frame
3 ALARM CO2 frame
4 ALARM HEAT frame
5 ALARM WATER frame
255 Control frame BASIC_SET

Parameter 6: Type of control frame activated via IN input 2

The parameter allows you to specify the type of an alarm frame for Input 2
Size: 1 Byte, Default Value: 255

Setting Description
0 ALARM GENERIC frame
1 ALARM SMOKE frame
2 ALARM CO frame
3 ALARM CO2 frame
4 ALARM HEAT frame
5 ALARM WATER frame
255 Control frame BASIC_SET

Parameter 7: Value of the parameter specifying the forced level of dimming/opening roller blinds from Input 1

In case of alarm frames an alarm priority is specified. Value of 255 makes it possible to activate a device. In case of the Dimmer module it means activating the device and setting it to the previously stored condition, e.g. when Dimmer is set to 30%, deactivated and then reactivated using 255 commend, it will be automatically set to the previous condition i.e. 30%.
Size: 1 Byte, Default Value: 0

Setting Description
1 - 99 Dimming level
255 Turn On

Parameter 8: Value of the parameter specifying the forced level of dimming/opening roller blinds from Input 2

In case of alarm frames an alarm priority is specified. Value of 255 makes it possible to activate a device. In case of the Dimmer module it means activating the device and setting it to the previously stored condition, e.g. when Dimmer is set to 30%, deactivated and then reactivated using 255 commend, it will be automatically set to the previous condition i.e. 30%.
Size: 1 Byte, Default Value: 0

Setting Description
1 - 99 Dimming level
255 Turn On

Parameter 9: Deactivating transmission of the alarm cancelling frame or the control frame deactivating the device (Basic)

It allows for disabling the function of deactivating the device and cancelling alarms for devices associated with IN input.
Size: 1 Byte, Default Value: 0

Setting Description
0 information is sent to group 1 and 2
1 information is not sent for group 2 but sent for group 1
2 information is not sent for group 1 but sent for group 2
3 information is not sent

Parameter 10: Interval between successive readings of temperature from all sensors connected to the device.


Size: 1 Byte, Default Value: 200

Setting Description
0 disable
1 - 255 seconds

Parameter 11: Sende Interval Temperaturwerte

Interval between forcing to send report concerning the temperature conditions. The forced report is sent immediately after the next reading of temperature from the sensor, irrespective of the settings of parameter no. 12. Frequent sending of temperature condition reports is reasonable when the sensor is located somewhere where can occure rapid changes of ambient temperature. In other cases it is recommended to leave the parameter set to the default value.
Size: 1 Byte, Default Value: 20

Setting Description
1 - 255 seconds

Parameter 12: Trigger level to send out temperature report

defines the maximum deviation of the actual temperature compared to the last wirelessly reported temperature to create a new wireless report to the device in association group 3. If set to zero a report will be generated at every regular wakeup of the device but as a minimum every 4 minutes.
Size: 1 Byte, Default Value: 8

Setting Description
0 information about the temperature will be sent every time, immediately once the readings have been taken from the sensor
1 - 255 0,0625°C - 16°C (step 0,0625°C)

Parameter 13: Sending an alarm or control frame (for IN input, depending on parameter no.5 value), and TMP button alarm frame

The frame is sent in broadcast mode, i.e. to all devices within range - information sent in this mode is not repeated by the mesh network.
Size: 1 Byte, Default Value: 0

Setting Description
0 IN1 and IN2 Broadcast mode inactive
1 IN1 broadcast mode active, IN2 broadcast mode inactive
2 IN1 broadcast mode inactive, IN2 broadcast mode active
3 IN1 and IN2 broadcast mode active

Parameter 14: Scene activation functionality

IN input: Switch from (off to on) ID10; Switch from (on) to (off) ID11; Remaining IDs are recognized correctly if the value of parameter no.3 was set to 2 Holding down ID12; Releasing ID13; Double click ID14; Triple click ID 15; Scene activation functionality may shorten the battery life, even by 25%.
Size: 1 Byte, Default Value: 0

Setting Description
0 functionality deactivated
1 functionality activated

Technical Data

Dimensions 0.0175000x0.0290000x0.0131100 mm
Weight 10 gr
Hardware Platform ZM3102
EAN 5902020528074
Device Type Routing Binary Sensor
Generic Device Class Binary Sensor
Specific Device Class Routing Binary Sensor
Firmware Version 03.31
Z-Wave Version 03.22
Z-Wave Product Id 010f.0501.0101
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeRouting Binary Sensor