Inclusion, Exclusion and wakeup are confirmed by triple clicking the Z-Wave button inside the case.
The Fibaro Flood Sensor will alert you of a threatening flood or a rapid temperature rise or drop and has a wide variety of additional functions. Thanks to its flexible gold telescopic probes the device can even work on uneven surfaces. The Flood Sensor has a built in alarm siren which will help you to react quickly in case of a flood, rapid temperature change or the attempt to tamper with it. Aside from the alarm siren, the device can alert you of a threat using colour displays from the built in RGB diode. In addition to this a tilt sensor will detect tilt and movement over 15 degrees and send out a report to the main controller. The built in temperature sensor can not only be used to serve as a fire alarm sensor, it may also be used to manage an in-floor heating system.
The Input terminal allows you to connect an external probe and install the sensor in any location. The Output terminal allows for a connection to an alarm system. The Sensor will work on 12 or 24V DC or battery.
There are two powering modes for the Fibaro Flood Sensor, battery or mains current. By default it"s powered by a factory included battery. In addition it can work with a constant current, after connecting a 12 / 24V DC power supply to +12 and GND terminals. Powering mode configuration is carried out automatically, while a sensor is being included into the Z-Wave network. When battery powered, a Fibaro Flood Sensor communicates with a Z-Wave network main controller periodically. Detected alarms are sent immediately, but configuration parameters and associations settings only at specified wake up intervals, or at a manual wake up (button triple click). In DC powering mode, configuration and associations parameters are sent when necessary, and in addition a sensor serves as a Z-Wave signal repeater.
Switching to a constant current powering mode:
In constant powering mode a sensor may operate without a battery. Installing a battery is recommended though, as it will serve as an emergency power source. When constant power fails, sensor will automatically shift to an emergency mode. All reports, including flood and temperature, will be sent immediately, but it will not be possible to modify the configuration or association settings until constant power returns. If a sensor served as a signal repeater for other Z-Wave devices, in emergency mode signal repeating function will be deactivated.
Note: Fibaro Flood Sensor will automatically exit emergency mode once 12/24 VDC at +12 and GND terminals is detected and the device wakes up after detecting an event, i.e. flood alarm, temperature report, tilt, or manual wake up using button.
The Flood Sensor can also be used with an additional extended wire for the water sensor. Drill a hole into the casing and connect the wire as shown in figure 2.
Fibaro Flood Sensor has two sensors built in - flood and temperature sensors, meaning it"s a multichannel device. In the Z-Wave network"s main controller the Sensor will be shown as two devices.
Through an association Fibaro Flood Sensor may control another Z-Wave network device, e.g. a Dimmer, Relay Switch, Roller Shutter, RGBW Controller, Wall Plug, or a scene (scene only through the Home Center 2 main controller).
Fibaro Flood Sensor allows for the associations of three groups.
1-st Association Group is assigned to the device status - sending the BASIC SET (default) or ALARM control frame to the associated devices.
2-nd Association Group is assigned to a TMP button and tilt sensor - ALARM GENERIC control frame will be sent to the associated devices in case a TMP button is released or a tilt sensor triggered (depending on parameter 74 settings).
3-rd Association Group reports the device status and allows for assigning single device only (the main controller by default - the device reports its status to the main controller).
Fibaro Flood Sensor allows for controlling 5 regular and 5 multichannel devices per an association group, out of which 1 field is reserved for the Z-Wave network main controller.
Z-Wave Range Test
Fibaro Flood Sensor has a built in Z-Wave network range test for the main controller. Follow the instruction to test the main controller"s range:
Z-Wave Range Tester signaling modes:
LED Indicator pulsing green - Fibaro Flood Sensor attempts to directly communicate with the main controller. If the direct communication attempt fails, the sensor will try routed communication, through other devices, which will be signaled with LED Indicator blinking yellow.
LED Indicator glowing green - Fibaro Flood Sensor directly communicating with the main controller.
LED Indicator pulsing yellow - Fibaro Flood Sensor tries to establish routed connection with the main controller, through intermediary devices.
LED Indicator glowing yellow - Fibaro Flood Sensor communicates with the main controller through other, intermediary devices. After two seconds the Sensor will retry to directly connect to the main controller, which will be signaled with the Indicator pulsing green.
LED Indicator pulsing violet - Fibaro Flood Sensor communicates at the range limit. If connection proves successful it will be confirmed with a yellow glow. It"s not recommended to use the sensor at the range limit.
LED Indicator glowing red - Fibaro Flood Sensor unable to connect to the main controller directly or through another Z-Wave network nodes.
Reset to factory default | Reset procedure deletes EPROM"s memory, including all information on the Z-Wave network and the main controller. Fibaro Flood Sensor"s reset procedure: 1. Make sure the Sensor is powered. 2. Press and hold a TMP button for 15 - 20 seconds. LED indicator glows yellow to confirm entering 4th sub-menu. 3. Release the TMP button. 4. Click the TMP button, once. 5. The LED indicator glowing red and then turning off will confirm a successful reset. Reset completion will be confirmed by an acousic signal, same as at the power source connection. |
Inclusion | Make sure that your Z-Wave Controller is in the Inclusion-/Exclusion-Mode. Tripple click the Z-Wave button inside the case to confirm the process. |
Exclusion | Make sure that your Z-Wave Controller is in the Inclusion-/Exclusion-Mode. Tripple click the Z-Wave button inside the case to confirm the process. |
NIF | Tripple click on the Z-Wave button inside the case or a detection by one of the sensors will send a Node Information Frame. |
Wakeup | Tripple click on the Z-Wave button inside the case will wake up the device. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Flood Alarm with BASIC SET |
2 | 5 | Tilt Sensor alarm and TMP button events |
3 | 1 | reports device status |
Delays flood alarm cancelation for the device after flooding has ceased Size: 2 Byte, Default Value: 0000
Setting | Description |
---|
parameter allows for LED indicator and acoustic alarm deactivation in case of flooding detection Size: 1 Byte, Default Value: 03
Setting | Description |
---|---|
00 | acoustic and visual alarms inactive |
01 | acoustic alarm inactive, visual alarm active |
02 | acoustic alarm active, visual alarm inactive |
03 | acoustic and visual alarms active |
parameter determines a type of command frame sent by the Sensor in case flooding has been detected or cancelled Size: 1 Byte, Default Value: 81
Setting | Description |
---|---|
00 | ALARM WATER command frame |
81 | BASIC SET command frame |
Forced dimming level / roller blind opening level, when sending turn on / open Size: 1 Byte, Default Value: 63
Setting | Description |
---|
Allows for deactivating device turn off and alarm cancellation functions for the devices assigned to 1-st association group Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Alarm (flooding) cancellation inactive |
01 | Alarm (flooding) cancellation active |
Time interval, in seconds, between consecutive temperature measurements Size: 2 Byte, Default Value: 012c
Setting | Description |
---|
Determines a minimum temperature change value (insensitivity level), resulting in a temperature report being sent Size: 2 Byte, Default Value: 0032
Setting | Description |
---|
Value other than 0 means alarms are sent in BROADCAST mode (with a priority over other communicates), to all devices within the Sensoru2019s range Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | broadcasts inactive |
01 | flood (1-st Association Group) broadcast active; tamper (2-nd Association Group) broadcast inactive |
02 | flood broadcast inactive; tamper broadcast active |
03 | flood broadcast active; tamper broadcast active |
parameter stores a temperature value, below which LED indicator blinks with a definable colour Size: 2 Byte, Default Value: 05dc
Setting | Description |
---|
parameter stores a temperature value, above which LED indicator blinks with a definable colour Size: 2 Byte, Default Value: 0dac
Setting | Description |
---|
Parameter stores RGB colour value Size: 4 Byte, Default Value: 000000ff
Setting | Description |
---|
Parameter stores RGB colour value Size: 4 Byte, Default Value: 00ff0000
Setting | Description |
---|
Parameter determines LED indicatoru2019s operation. Set to 0 turns the indicator off, saving a battery life Size: 1 Byte, Default Value: 02
Setting | Description |
---|---|
00 | LED indicator doesnu2019t indicate the temperature |
01 | LED indicator indicates the temperature (blink) every Temperature Measurement Interval (Parameter 10, constant current and battery) or Wake Up Interval (battery mode) |
02 | LED indicator indicates the temperature continuously, only in constant power mode |
Parameter stores a temperature value to be added to or deducted from the current temperature measured to compensate temperature deflection Size: 2 Byte, Default Value: 0000
Setting | Description |
---|
parameter to device wich sensors send Alarm to 2. association group Size: 1 Byte, Default Value: 02
Setting | Description |
---|---|
00 | tamper alarms inactive |
01 | button tamper alarm active |
02 | movement tamper alarm active |
03 | button and movement tampers alarm active |
parameter determines a time period after which visual and audible alarm will become u201cquietu201d Size: 2 Byte, Default Value: 0000
Setting | Description |
---|
Parameter determines a time period after which an alarm frame will be retransmitted Size: 2 Byte, Default Value: 0000
Setting | Description |
---|
Allows for turning off the internal flood sensor. Tamper and built in temperature sensor will remain active. Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Default flood sensor operation (flood detection, reactions) |
01 | Built in flood sensor TURNED OFF (doesnu2019t change its state in the main controller, doesnu2019t send Alarms and Basic Set frames with flood state changes. Always visible in the main controller as turned off) |
Dimensions | 0.0650000x0.0650000x0.0280000 mm |
Weight | 41 gr |
EAN | 5902020528142 |
Battery Type | 1 * CR123 |
Firmware Version | 17.17 |
Z-Wave Version | 03.34 |
Certification ID | ZC08-14040015 |
Z-Wave Product Id | 010f.0b00.1001 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |