Quickstart

This is a Valve for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
This must be done when the Gas valve is closed.After doing inclusion action on controller, then hold 5 seconds (-) button until you hear a beep once and P is blinking on LCD.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

U+ Gas lock helps users easily check and turn off the gas valves in home from anywhere. It detects dangerous temperature and alerts potential danger situations so that users can handle a problem. In addition, users can set time to lock gas valves against danger.

Reset to factory default Please use this only when the primary controller is missing or otherwise disabled.This must be done when the Gas valve is closed.Hold 15 seconds (-) button until you hear a beep once and FS is displayed on LCD.
Inclusion This must be done when the Gas valve is closed.After doing inclusion action on controller, then hold 5 seconds (-) button until you hear a beep once and P is blinking on LCD.
Exclusion This must be done when the Gas valve is closed.After doing exclusion action on controller, then hold 5 seconds (-) button until you hear a beep once and P is blinking on LCD.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 1: Sound volume setting

0x00: Mute,0x01: Minimum sound volume,0x02: Default sound volume,0x03: Maximum sound volume,
Size: 1 Byte, Default Value: 2

Setting Description
0 - 3 Sound volume setting

Parameter 2: Valve auto lock time setting

This must be done when the Gas valve is open.Upper byte value: hour,Lower byte value: minute,Setting Range : 2min ~9hr 59min (0x0002 ~ 0x093B)
Size: 2 Byte, Default Value: 256

Setting Description
2 - 2363 00(0hr)02(2min) ~ 09(9hr)3B(59min)

Technical Data

Hardware Platform ZM5101
Device Type Valve
Network Operation Listening Sleeping Slave
Firmware Version HW: 1 FW: 39.132
Z-Wave Version 6.61.00
Certification ID ZC10-17055595
Z-Wave Product Id 0x018B.0x0040.0x0001
Color White
Outdoor Use ok
Firmware Updatable Not Updatable
IP (Ingress Protection) Rated ok
Frequency XXfrequency
Maximum transmission power XXantenna
South KoreaValve