This is a
Touch Keypad with palm. Enter User Code(Normal Mode only. Enter Master Code if operating Master Mode). Press 'I' button [Registration] from the inside of battery cover.£ Press 9, #, 1, # by sequence on the keypad(to Add). Wait until "Ding dong dang" melody play, then press 'I' button [Registration] from the inside of battery cover.
A Rim type Digital Door Lock for Smart Home services.'A20-SH' is a security enabled Z-Wave Plus product for Korean domestic market. It can be included and operated in any Z-Wave network with other Z-Wave certified devices.
Reset to factory default | This product has no function to go back to the factory default. |
Inclusion | Touch Keypad with palm. Enter User Code(Normal Mode only. Enter Master Code if operating Master Mode). Press 'I' button [Registration] from the inside of battery cover.£ Press 9, #, 1, # by sequence on the keypad(to Add). Wait until "Ding dong dang" melody play, then press 'I' button [Registration] from the inside of battery cover. |
Exclusion | Touch Keypad with palm. Enter User Code(Normal Mode only. Enter Master Code if operating Master Mode). Press 'I' button [Registration] from the inside of battery cover.£ Press 9, #, 3, # on the keypad by sequence (to Delete). Enter User Code(Normal Mode only. Enter Master Code if operating Master Mode), then press #. Wait until "Ding dong dang" melody play, then press 'I' button [Registration] from the inside of battery cover. |
NIF | XXXNIF |
Wakeup | The lock is always in "wake up status".However, touch keypad with palm to begin and end actions. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
2 | 5 | association |
set the silent mode on or off Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 | mute |
2 | volume low |
3 | volume high |
set the Auto relock on/off Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disable auto relock |
255 | enable auto relock |
set the relock time Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
10 - 180 | This value from 10 to 180 seconds means the time for lock to retain the unlocked state before doing the auto relock |
Hardware Platform | ZM5202 |
Device Type | Door Lock Keypad |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 255 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-15080019 |
Z-Wave Product Id | 0x0212.0x1000.0x1000 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |