Quickstart

This is a On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. Auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.
NOTE: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply , connect the sensor and re-include the module.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Flush 2 relays module is used for switching on or off two electrical devices (e.g. lights, fans, etc ...). The module can be controlled either through Z-Wave network or through the wall switches.
The module is designed to be mounted inside a “flush mounting box”, hidden behind a traditional wall switch.
Module measures power consumption of two electrical devices and supports connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-wave network.

Installation

• To prevent electrical shock and/or equipment damage, disconnect electrical power at the main fuse or circuit breaker before installation or any servicing.
• Make sure, that no voltage is present in the installation.
• Prevent the disconnecting device from being switched on accidentally.
• Connect the module according to electrical diagram.
• Locate the antenna far from metal elements (as far as possible).
• Do not shorten the antenna.


Product Usage

Reset to factory default If the service button S is pressed for mor ethan 6 seconds the module will be reset to the factory defoult state
Inclusion • Press service button S for more than 2 second or press push button I1 three times within 3s (3 times change switch state within 3 seconds).
Exclusion • Press service button S for more than 6 second or press push button I1 five times within 3s ( 5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply.
Note: By this function all parameters of the module are set to default values and own ID is deleted. If service button S is pressed more than 2 and less than 6second module is excluded, but configuration parameters are not set to default values
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Lifeline group (reserved for communication with the main controller).
2 16 basic on/off (triggered at change of the output Q1 state and reflecting its state)
3 16 switch binary report (triggered at change of the output Q1 state and reflecting its state)
4 16 power meter report (triggered at change of the output Q1 state)
5 16 basic on/off (triggered at change of the output Q2 state and reflecting its state)
6 16 switch binary report (triggered at change of the output Q2 state and reflecting its state)
7 16 power meter report (triggered at change of the output Q2 state)
8 16 multilevel sensor report (triggered at change of temperature sensor)

Configuration Parameters

Parameter 1: Input 1 switch type

Input 1 switch type
Size: 1 Byte, Default Value: 1

Setting Description
0 mono-stable switch type (push button)
1 bi-stable switch type

Parameter 2: Input 2 switch type

Input 2 switch type
Size: 1 Byte, Default Value: 1

Setting Description
0 mono-stable switch type (push button)
1 bi-stable switch type

Parameter 10: Activate / deactivate functions ALL ON/ALL OFF

Activate / deactivate functions ALL ON/ALL OFFFlush 2 relays module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.
Size: 2 Byte, Default Value: 255

Setting Description
0 ALL ON is not active ALL OFF is not active
1 ALL ON is not active ALL OFF active
2 ALL ON active ALL OFF is not active
255 ALL ON active, ALL OFF active

Parameter 11: Automatic turning off output Q1 after set time

When relay Q1 is ON it goes automatically OFF after time defined by this parameter. Timer is reset to zero each time the module receive ON command regardless from where it comes (push button, associated module, controller,..).
Size: 2 Byte, Default Value: 0

Setting Description
0 Auto OFF disabled
1 - 32535 1second (0,01s) - 32535 seconds (325,35s) Auto OFF enabled with define time, step is 1s or 10ms according to parameter nr.15

Parameter 12: Automatic turning on output Q1 after set time

When relay Q1 is OFF it goes automatically ON after time defined by this parameter. Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..).
Size: 2 Byte, Default Value: 0

Setting Description
0 Auto ON disabled
1 - 32535 1second (0,01s) - 32536 seconds (325,35s) Auto ON enabled with define time, step is 1s or 10ms according to parameter nr.15

Parameter 13: Automatic turning off output Q2 after set time

When relay Q2 is ON it goes automatically OFF after time defined by this parameter. Timer is reset to zero each time the module receive ON command regardless from where it comes (push button, associated module, controller,..).
Size: 2 Byte, Default Value: 0

Setting Description
0 Auto OFF disabled
1 - 32535 1second (0,01s) - 32535 seconds (325,35s) Auto OFF enabled with define time, step is 1s or 10ms according to parameter nr.15

Parameter 14: Automatic turning on output Q2 after set time

When relay Q2 is OFF it goes automatically ON after time defined by this parameter. Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..).
Size: 2 Byte, Default Value: 0

Setting Description
0 Auto ON disabled
1 - 32535 1second (0,01s) - 32536 seconds (325,35s) Auto ON enabled with define time, step is 1s or 10ms according to parameter nr.15

Parameter 15: Automatic turning off / on seconds or milliseconds selection

Automatic turning off / on seconds or milliseconds selectionNote that parameter is valid for both outputs Q1, Q2 and is the same for turning off or on.
Size: 1 Byte, Default Value: 0

Setting Description
0 seconds selected
1 milliseconds selected

Parameter 30: Saving the state of the relays Q1 and Q2 after a power failure

Saving the state of the relays Q1 and Q2 after a power failure
Size: 1 Byte, Default Value: 0

Setting Description
0 Flush 2 relays module saves its state before power failure (it returns to the last position saved before a power failure)
1 Flush 2 relays module does not save the state after a power failure, it returns to "off" position.

Parameter 40: Power reporting in Watts on power change for Q1

Set value means percentage, set value from 0 - 100 = 0% - 100%.
Size: 1 Byte, Default Value: 10

Setting Description
0 Reporting Disabled
1 - 100 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set.

Parameter 41: Power reporting in Watts on power change for Q2

Set value means percentage, set value from 0 - 100 = 0% - 100%
Size: 1 Byte, Default Value: 10

Setting Description
0 Reporting Disabled
1 - 100 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set.

Parameter 42: Power reporting in Watts by time interval for Q1

Set value means time interval (0 - 32535) in seconds, when power report is send.
Size: 2 Byte, Default Value: 300

Setting Description
0 Reporting Disabled
1 - 32535 = 1 second - 32535 seconds. Reporting enabled, Power report is send with time interval set by entered value.

Parameter 43: Power reporting in Watts by time interval for Q2

Set value means time interval (0 - 32535) in seconds, when power report is send.
Size: 2 Byte, Default Value: 300

Setting Description
0 Reporting Disabled
1 - 32535 = 1 second - 32535 seconds. Reporting enabled, Power report is send with time interval set by entered value.

Parameter 63: Output Q1 Switch selection

Set value means the type of the device that is connected to the Q1 output. The device type can be normally open (NO) or normally close (NC).
Size: 1 Byte, Default Value: 0

Setting Description
0 When system is turned off the output is 0V (NC).
1 When system is turned off the output is 230V (NO).

Parameter 64: Output Q2 Switch selection

Set value means the type of the device that is connected to the Q2 output. The device type can be normally open (NO) or normally close (NC).
Size: 1 Byte, Default Value: 0

Setting Description
0 When system is turned off the output is 0V (NC).
1 When system is turned off the output is 230V (NO).

Parameter 110: Temperature sensor offset settings

Set value is added or subtracted to actual measured value by sensor.
Size: 2 Byte, Default Value: 32536

Setting Description
1 - 100 value from 0.1 deg.C to 10.0 deg.C is added to actual measured temperature.
1001 - 1100 value from -0.1 deg.C to -10.0 deg.C is subtracted to actual measured temperature.
32536 offset is 0.0 deg.C

Parameter 120: Digital temperature sensor reporting

If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter.
Size: 1 Byte, Default Value: 5

Setting Description
0 Reporting disabled
1 - 127 0,1 deg.C - 12.7 deg.C. - step is 0,1 deg.C

Technical Data

Dimensions 42x37x16 mm
Weight 28 gr
Hardware Platform ZM5202
EAN 3830062070119
IP Class IP 20
Voltage 230 V
Load 2x 4A
Device Type On/Off Power Switch
Network Operation Always On Slave
Z-Wave Version 6.51.06
Certification ID ZC10-15100010
Z-Wave Product Id 0x0159.0x0002.0x0051
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeOn/Off Power Switch