This is a
- press service button S for more than 2 second
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
This Z-Wave module is used for energy measurements in single-phase electrical power network and can be used in residential, industrial and utility applications. Meters measure energy directly in 2-wire networks according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates energy, power and power factor from the measured signals. The module can be controlled through Z-wave network and it acts as repeater in order to improve range and stability of Z-wave network. It is designed to be mounted on DIN rail.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
- press service button S for more than 6 second
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
- To prevent electrical shock and/or equipment damage, disconnect electrical power: remove main fuse or put on OFF position a main disconnection switch (or circuit breaker if it is compliant to standard IEC947-2), before installation or any servicing.
- Make sure, that no voltage is present in the installation.
- Prevent the disconnecting device from being switched on accidentally.
- Connect the module according to electrical diagram.
- Locate the antenna far from metal elements (as far as possible).
- Do not shorten the antenna
Notes for the diagram:
LI Live input
NI Neutral input
Lo Live output
No Neutral output
1 Input for IR external relay/Ext. relay
2 Neutral lead for input
4 Live lead for External relay output
5 Output for External relay (max. 3W)
S Service button (used to add or remove module from the Z-Wave network).
LED1 Green - Power on (solid) / no ID (blinking slow 1s) / Inc./Exc. mode (blinking fast 0,5s)
LED2 Yellow on – output on (any) / Yellow off – outputs off (both)
IR Output for IR external relay
1imp/Wh Red - Pulse rate (On – no load indication)
External relays
It is possible to connect two external relay to Smart Meter module. One controlled by built-in optical (IR) communication port on the side, second controlled by output on terminal 5.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
0 | disabled |
2 | IR external relay control – mono stable push button |
3 | IR external relay control - bi stable switch |
4 | External relay control – mono stable push button |
5 | External relay control – bi stable switch |
Only for older Version! Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
255 | ALL ON active, ALL OFF active. |
0 | ALL ON is not active, ALL OFF is not active |
1 | ALL ON is not active, ALL OFF active |
2 | ALL ON active, ALL OFF is not active DIN Dimmer module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. |
When IR external relay is ON it goes automatically OFF after time defined by this Parameter. Timer is reset to zero each time the module receive ON command regardless from where it comes (push button, associated module, controller,..) Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 59 | Auto OFF disabled |
60 - 32535 | Auto OFF enabled with define time, step is 1s |
When IR external relay is OFF it goes automatically ON after time defined by this Parameter. Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..). Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 59 | Auto ON disabled |
60 - 32535 | Auto ON enabled with define time, step is 1s. |
When External relay is ON it goes automatically OFF after time defined by this parameter. Timer is reset to zero each time the module receive ON command regardless from where it comes (push button, associated module, controller,..). Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 59 | Auto OFF disabled |
60 - 32535 | Auto OFF enabled with define time, step is 1s |
When External relay is OFF it goes automatically ON after time defined by this parameter. Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..). Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 59 | Auto ON disabled |
60 - 32535 | Auto ON enabled with define time, step is 1s |
Set value means percentage, set value from 0 - 100=0% - 100%. NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | reporting disabled |
1 - 100 | 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. |
Set value means time interval (0 – 32767) in seconds, when power report is send. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 59 | reporting disabled |
60 - 32767 | Reporting enabled. Power report is send with time interval set by entered value. Please note, that too fast reporting can cause too much Z-Wave traffic resulting in Z-Wave poor response |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | no function |
1 | reset counter 1 – KWh |
2 | reset counter 2 – kVARh |
4 | reset counter 3 – kVAh |
15 | reset ALL counters |
Enabling IR external relay and External relay or both of them, means that endpoint (IR external relay) and endpoint (External relay) or both will be present on UI. Disabling them will result in hiding endpoints according to Parameter set value. Note that hiding endpoint has no impact on its functionality.NOTE1: After parameter change, first exclude module (without setting parameters to default value) and then re include the module. NOTE2: If you dont have IR BiComm relay module mounted and you enable IR communication (parameter 100 is 2 or 3) there will be no valid IR relay state reported. It will be reported IR COMMUNICATION ERROR and LED2 will BLINK. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Endpoints IR external relay and External relay disabled |
1 | Endpoints IR external relay disabled, External relay enabled |
2 | Endpoints IR external relay enabled, External relay disabled |
3 | Endpoints IR external relay and External relay enabled |
Set value means Maximum Power Consumption (0 - 15000) in watts (W), when relays are turned off according to parameters no. 111 and 112. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | no function |
1 - 15000 | 1 W - 15000 W Maximum Power Consumption. |
Set value means number of second to power off relay (defined by parameters no. 110 and 112) before restart (30 - 32535) in seconds (s) Size: 2 Byte, Default Value: 30
Setting | Description |
---|---|
30 - 32535 | 30 s – 32535 s delay |
Set value selects relay to be powered off when threshold is reached (defined by parameters no. 110 and 111). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | switch between the 2 relays (power off relay 1 first, after power on, if power consumption is still over, power off relay 2, ..) |
1 | always power off relay 1 (IR external relay) |
2 | always power off relay 2 (External relay) |
3 | always power off both relays (relay 1 and relay 2) |
Since Version 7.6 Size: 4 Byte, Default Value:
Setting | Description |
---|
Dimensions | 36x90x64mm mm |
Weight | 140 gr |
Hardware Platform | ZM5202 |
EAN | 3830062070362 |
IP Class | IP 20 |
Voltage | 230 V |
Load | 65 A |
Device Type | Smart Meter |
Firmware Version | 07.06 |
Z-Wave Version | 04.3d |
Certification ID | ZC10-18086203 |
Z-Wave Product Id | 0x0159.0x0007.0x0052 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |