This is a
Toggle the Service button S between 0.2 and 6 seconds
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
The Qubino Smart Meter is an extremely versatile and powerful Z-Wave module for measuring energy in a single-phase electrical power network of up to 65A. A built-in microprocessor calculates energy, power and power factor from the measured signals. It is designed to be mounted on a DIN rail.
The Qubino Smart Meter can be used in residential, industrial and utility applications. It measures energy directly in 2-wire networks by means of fast sampling of voltage and current signals. It calculates energy, power and power factor from the measured signals. You can control the module through the Z-Wave network. It also acts as a repeater in order to improve the range and stability of the Z-Wave network. The Smart Meter is designed to be mounted on a DIN rail.
Properties:
Main terminals (LI,NI,Lo,No)
Optional terminals (1,2,4,5)
Measuring input
Accessory
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Press and hold the S service button between 6 seconds and 20 seconds
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
The 3-Phase Smart Meter can be used in many different scenes, which can help make your life more comfortable. We have prepared a few of them for you so you can get an idea for your next smart home project. Of course, there are countless of other options for how to use Qubino 3-Phase Smart Meter to remotely control devices via your smartphone.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Available configuration parameters for input switch I1 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | disabled |
2 | IR external relay control – mono stable push button |
3 | IR external relay control – bi-stable switch |
4 | External relay control – mono stable push button |
5 | External relay control – bi-stable switch |
This parameter is valid for Active Power Total, Active Power Phase1, Active Power Phase2 and Active Power Phase3.
NOTE: if power change is less than 5 W, the report is not send (pushed).NOTE: Device is measuring also some disturbances even if on the output is no load. To avoid disturbances:- If measured Active Power (W) is below e.g. 5W-> the reported value in this case is 0W
Size: 1 Byte, Default Value: 50
Setting | Description |
---|---|
0 | reporting disabled |
1 - 100 | 1% - 100% reporting enabled. Power report is send only when actual power in Watts (in real time changes for more than set percentage comparing to previous Active Power, step is 1%. |
This parameter is currently valid only for Active Energy Total Import/Export (kWh), Reactive Energy Total (kvarh), Total Energy (kVAh)
Note: Device is reporting only if there was a change of 0.1 in EnergyNote: In the future will be possible to measure and report also Active Energy on PH1, PH2 and PH3.
Size: 2 Byte, Default Value: 600
Setting | Description |
---|---|
0 | reporting disabled |
600 - 65536 | Reporting enabled. Report is send with the time interval set by entered value. Seconds |
This parameter is valid only for Voltage (V of ph1, ph2, ph3), Current (A of ph1, ph2, ph3), Total Power Factor, Total Reactive Power (var)
Note: Device is reporting only if there was a change
Size: 2 Byte, Default Value: 600
Setting | Description |
---|---|
0 | reporting disabled |
600 - 65536 | Reporting enabled. Report is send with the time interval set by entered value. Seconds |
NOTE1: After parameter change, first exclude module (without setting parameters to default value) and then re include the module.NOTE 2: If you don‘t have IR BICOM relay module mounted and you enable IR communication (parameter 100 is 1 or 2) there will be no valid IR relay state reported. It will be reported IR COMMUNICATION ERROR and LED2 will BLINK. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | External IR relay disabled |
1 | External IR relay enabled and connected to all 3 Phases |
2 | External IR relay enabled and connected to a Phase 1 |
After parameter change, first exclude module (without setting parameters to default value) and then re include the module. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | External relay disabled |
1 | External relay enabled and connected to Phase 2 |
This parameter defines a threshold when External IR relay is being turned off. (If Parameter no. 100 is set to the value 1 or 2)
NOTE: Meter is capable of measuring max 3x65A!
Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | no function |
10 - 60000 | Watt |
This parameter defines a threshold when External relay is being turned off (if the parameter no. 100 is set to the value 1 or 2).
NOTE: Meter is capable of measuring max 65A
Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | no function |
10 - 20000 | Watt |
External IR relay/ External relay is turned off due to detected overload (as set by parameter 106&107) and remains off for a time, defined in this parameter. After that time, the output turns on to check, if the overload is still present.
NOTE: the delay time may be prolonged for more then 10s of the time set by the parameter.
Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | External IR relay/ External relay will not turn back on |
30 - 32535 | Seconds |
Dimensions | 53,6 x 84 x 65 mm |
Weight | 221 gr |
Hardware Platform | ZM5101 |
EAN | 3830062070683 |
IP Class | IP 20 |
Voltage | 3x 230 V/400V |
Load | 65 A |
Device Type | Smart Meter |
Firmware Version | 01.00 |
Z-Wave Version | 04.3d |
Certification ID | ZC10-19066549 |
Z-Wave Product Id | 0x0159.0x0007.0x0054 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |