Press the Service button S 3 times within 3 seconds
The Smart Plug 16A controls on/off function for the connected device. It also measures power consumption of the connected device according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates energy and power from the measured signals.
The Qubino Smart Plug 16A also acts as a Z-Wave repeater to improve the range and stability of the Z-Wave network.
Reset to factory default | Press service button S 5 times within 3 seconds ? reset the module to factory default and clear NIF+ send device reset locally |
Inclusion | Press the Service button S 3 times within 3 seconds |
Exclusion | Press the Service button S 3 times within 3 seconds |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline |
2 | 5 | This group is assigned to Plug status ? On/Off. Allows for sending control command BASIC_SET 0x00/0xFF to associated devices whenever the Plug is turned On or Off. |
3 | 5 | This group allows for sending control commands BASIC_SET 0x00/0xFF to associate devices depending on the current load. This association group is configured through the advanced parameters no. 50, 51 and 52 |
4 | 5 | This group is equivalent to the association group no. 2. The difference is, that this group sends commands Secure Encapsulated. |
5 | 5 | This group is equivalent to the association group no. 3. The difference is, that this group sends commands Secure Encapsulated. |
Smart Plug 16A device responds to commands ALL ON / ALL OFF that may be sent by the primary or secondary gateway (hub) within the Z-Wave network. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
0 | ALL ON not active, ALL OFF not active |
1 | ALL ON not active, ALL OFF active |
2 | ALL ON active, ALL OFF not active |
255 | ALL ON active, ALL OFF active |
If Smart plug 16A is ON, you can schedule it to turn OFF automatically after a period of time defined in this parameter. The timer is reset to zero each time the device receives an ON command, either remotely (from the gateway (hub) or associated device) or locally from the switch. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Auto OFF Disabled |
1 - 32535 | seconds (or milliseconds ? see Parameter no. 15) Auto OFF timer enabled for a given amount of seconds (or milliseconds) |
If Smart plug 16A is OFF, you can schedule it to turn ON automatically after a period of time defined in this parameter. The timer is reset to zero each time the device receives an OFF command, either remotely (from the gateway (hub) or associated device) or locally from the switch. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 - 32535 | seconds (or milliseconds ? see Parameter no. 15) Auto ON timer enabled- for a given amount of seconds (or milliseconds) |
Choose if you want to set the timer in seconds or milliseconds in parameters 11 and 12. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | timer set in seconds |
1 | timer set in milliseconds |
This parameter determines if on/off status is saved and restored for the Smart plug 16A after power failure. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Device saves last on/off status and restores it after a power failure. |
1 | Device does not save on/off status and does not restore it after a power failure, it remains off. |
Choose by how much power consumption needs to increase or decrease to be reported. Values correspond to percentages so if 20 is set (by default), the device will report any power consumption changes of 20% or more compared to the last reading. Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
0 | Power consumption reporting disabled |
1 - 100 | % Power consumption reporting enabled. New value is reported only when Wattage in real time changes by more than the percentage value set in this parameter compared to the previous Wattage reading, starting at 1% (the lowest value possible). |
Set value refers to the time interval with which power consumption in Watts is reported (0 ? 32535 seconds). The device is reporting the following values (if there was a change): W, V and A.
NOTE: The energy consumption (kWh) is reported regardless of the values, set in the parameters 40 and 42. The energy consumption will be reported, when it increases for at least 0,1 kWh.
Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Power consumption reporting on time interval disabled |
30 - 32535 | Seconds, Power consumption reporting enabled. Report is sent according to time interval (value) set here. |
Lower power threshold used in parameter no. 52. Down value cannot be higher than a value specified in parameter no. 51NOTE:if parameter no. 50 value is 100Wif measured power is lower than 100W, the association is sendassociation is send again if measured power will rise above 105WPower threshold step is 1W Size: 2 Byte, Default Value: 30
Setting | Description |
---|---|
0 - 4000 | Watt |
Upper power threshold used in parameter no. 52. Up value cannot be lower than a value specified in the parameter no. 50.NOTE:If parameter no. 51 value is 200WIf measured power is higher than 200W the association is sendAssociation is send again if measured power will fall below 190W Power threshold step is 1W Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 4000 | Watt |
The parameter defines the way 3rd association group devices are controlled, depending on the current power load Size: 1 Byte, Default Value: 6
Setting | Description |
---|---|
0 | function inactive |
1 | turn the associated devices on, once the power drops below Down value (parameter no. 50) |
2 | turn the associated devices off, once the power drops below Down value (parameter no. 50) |
3 | turn the associated devices on, once the power rises above Up value (parameter no. 51) |
4 | turn the associated devices off, once the power rises above Up value (parameter no. 51) |
5 | 1 and 4 combined. Turn the associated devices on, once the power drops below Down value (parameter no. 50). Turn the associated devices off, once the power rises above Up value (parameter no. 51). |
6 | 2 and 3 combined. Turn the associated devices off, once the power drops below Down value (parameter 50). Turn the associated devices on, once the power rises above Up value (parameter no. 51). |
The function allows for turning off the controlled device in case of exceeding the defined power for more than 3.1s. Controlled device can be turned back on by S-button or sending a control frame. By default this function is inactive. NOTE: This functionality is not an overload safety protection, please check installation note for details. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | function not active |
1 - 4000 | Watt |
Using this parameter it is possible to enable/disable reporting after the set command (i.e. Basic set). Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | disable reporting |
1 | enable reporting |
Dimensions | 43 x 52 x 75 mm |
Weight | 80 gr |
Hardware Platform | ZM5101 |
EAN | 3830062071505 |
IP Class | IP 20 |
Voltage | 230 V |
Load | 16A |
Device Type | On/Off Power Switch |
Generic Device Class | Binary Switch |
Specific Device Class | Binary Power Switch |
Firmware Version | 02.00 |
Z-Wave Version | 04.21 |
Certification ID | ZC10-18116325 |
Z-Wave Product Id | 0x0159.0x0002.0x0054 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |