Quickstart

This is a secure Binary Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Press the Service button S 3 times within 3 seconds



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The Smart Plug 16A controls on/off function for the connected device. It also measures power consumption of the connected device according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates energy and power from the measured signals.
The Qubino Smart Plug 16A also acts as a Z-Wave repeater to improve the range and stability of the Z-Wave network.

Product Usage


S
Service button (used to add or remove the Smart Plug 16A from the Z-Wave network and for turning the internal relay ON/OFF)

LED
When the Smart Plug 16A is excluded:
When the relay is turned OFF:
? blue LED is blinking (1 sec ON, 1 sec OFF)
When the relay is turned ON:
? blue LED is ON
? red LED is blinking (0.3 sec ON, 0.3 sec OFF) when the current exceeds 14,4A
? red LED is ON after the overload occurred
When the Smart Plug 16A is included:
When the relay is turned OFF:
? LED is OFF
When the relay is turned ON:
? blue LED is ON
? red LED is blinking (0.3 sec ON, 0.3 sec OFF) when the current exceeds 14,4A
? red LED is ON after the overload occurred

 
MEASUREMENTS:

V = Voltage
A = Current
W = Power ? Active
kWh = Energy ? Active power accumulated

Overcurrent protection
When load is for 5 sec over 16.1A, relay is automatically turned off and ?Overcurrent detected? notification is sent.
To reactivate the device, it has to be pulled out of the power socket and put in again.

Overcurrent warning
When load is near overcurrent state (over 14.4 A), Unsolicited Meter Report is sent and the red LED starts blinking. When the current returns below 14.4 A, the blue LED starts blinking automatically.

Reset to factory default Press service button S 5 times within 3 seconds ? reset the module to factory default and clear NIF+ send device reset locally
Inclusion Press the Service button S 3 times within 3 seconds
Exclusion Press the Service button S 3 times within 3 seconds
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Lifeline
2 5 This group is assigned to Plug status ? On/Off. Allows for sending control command BASIC_SET 0x00/0xFF to associated devices whenever the Plug is turned On or Off.
3 5 This group allows for sending control commands BASIC_SET 0x00/0xFF to associate devices depending on the current load. This association group is configured through the advanced parameters no. 50, 51 and 52
4 5 This group is equivalent to the association group no. 2. The difference is, that this group sends commands Secure Encapsulated.
5 5 This group is equivalent to the association group no. 3. The difference is, that this group sends commands Secure Encapsulated.

Configuration Parameters

Parameter 10: Activate / deactivate ALL ON / ALL OFF Functionality

Smart Plug 16A device responds to commands ALL ON / ALL OFF that may be sent by the primary or secondary gateway (hub) within the Z-Wave network.
Size: 2 Byte, Default Value: 255

Setting Description
0 ALL ON not active, ALL OFF not active
1 ALL ON not active, ALL OFF active
2 ALL ON active, ALL OFF not active
255 ALL ON active, ALL OFF active

Parameter 11: Turn Smart plug 16A Off Automatically with Timer

If Smart plug 16A is ON, you can schedule it to turn OFF automatically after a period of time defined in this parameter. The timer is reset to zero each time the device receives an ON command, either remotely (from the gateway (hub) or associated device) or locally from the switch.
Size: 2 Byte, Default Value: 0

Setting Description
0 Auto OFF Disabled
1 - 32535 seconds (or milliseconds ? see Parameter no. 15) Auto OFF timer enabled for a given amount of seconds (or milliseconds)

Parameter 12: Turn Smart plug 16A On Automatically with Timer

If Smart plug 16A is OFF, you can schedule it to turn ON automatically after a period of time defined in this parameter. The timer is reset to zero each time the device receives an OFF command, either remotely (from the gateway (hub) or associated device) or locally from the switch.
Size: 2 Byte, Default Value: 0

Setting Description
0 Disable
1 - 32535 seconds (or milliseconds ? see Parameter no. 15) Auto ON timer enabled- for a given amount of seconds (or milliseconds)

Parameter 15: Set Timer Units to Seconds or Milliseconds

Choose if you want to set the timer in seconds or milliseconds in parameters 11 and 12.
Size: 1 Byte, Default Value: 0

Setting Description
0 timer set in seconds
1 timer set in milliseconds

Parameter 30: Restore on/off status for Smart plug 16A after power failure

This parameter determines if on/off status is saved and restored for the Smart plug 16A after power failure.
Size: 1 Byte, Default Value: 0

Setting Description
0 Device saves last on/off status and restores it after a power failure.
1 Device does not save on/off status and does not restore it after a power failure, it remains off.

Parameter 14: Watt Power Consumption Reporting Threshold for Smart plug 16A

Choose by how much power consumption needs to increase or decrease to be reported. Values correspond to percentages so if 20 is set (by default), the device will report any power consumption changes of 20% or more compared to the last reading.
Size: 1 Byte, Default Value: 20

Setting Description
0 Power consumption reporting disabled
1 - 100 % Power consumption reporting enabled. New value is reported only when Wattage in real time changes by more than the percentage value set in this parameter compared to the previous Wattage reading, starting at 1% (the lowest value possible).

Parameter 42: Watt Power Consumption Reporting Time Threshold for Smart plug 16A Load

Set value refers to the time interval with which power consumption in Watts is reported (0 ? 32535 seconds). The device is reporting the following values (if there was a change): W, V and A. 
NOTE: The energy consumption (kWh) is reported regardless of the values, set in the parameters 40 and 42. The energy consumption will be reported, when it increases for at least 0,1 kWh.

Size: 2 Byte, Default Value: 0

Setting Description
0 Power consumption reporting on time interval disabled
30 - 32535 Seconds, Power consumption reporting enabled. Report is sent according to time interval (value) set here.

Parameter 50: Down value

Lower power threshold used in parameter no. 52. Down value cannot be higher than a value specified in parameter no. 51NOTE:if parameter no. 50 value is 100Wif measured power is lower than 100W, the association is sendassociation is send again if measured power will rise above 105WPower threshold step is 1W
Size: 2 Byte, Default Value: 30

Setting Description
0 - 4000 Watt

Parameter 51: Up value

Upper power threshold used in parameter no. 52. Up value cannot be lower than a value specified in the parameter no. 50.NOTE:If parameter no. 51 value is 200WIf measured power is higher than 200W the association is sendAssociation is send again if measured power will fall below 190W Power threshold step is 1W
Size: 2 Byte, Default Value: 50

Setting Description
0 - 4000 Watt

Parameter 52: Action in case of exceeding defined power values (parameters 50 and 51)

The parameter defines the way 3rd association group devices are controlled, depending on the current power load
Size: 1 Byte, Default Value: 6

Setting Description
0 function inactive
1 turn the associated devices on, once the power drops below Down value (parameter no. 50)
2 turn the associated devices off, once the power drops below Down value (parameter no. 50)
3 turn the associated devices on, once the power rises above Up value (parameter no. 51)
4 turn the associated devices off, once the power rises above Up value (parameter no. 51)
5 1 and 4 combined. Turn the associated devices on, once the power drops below Down value (parameter no. 50). Turn the associated devices off, once the power rises above Up value (parameter no. 51).
6 2 and 3 combined. Turn the associated devices off, once the power drops below Down value (parameter 50). Turn the associated devices on, once the power rises above Up value (parameter no. 51).

Parameter 70: Overload safety switch

The function allows for turning off the controlled device in case of exceeding the defined power for more than 3.1s. Controlled device can be turned back on by S-button or sending a control frame. By default this function is inactive. NOTE: This functionality is not an overload safety protection, please check installation note for details.
Size: 2 Byte, Default Value: 0

Setting Description
0 function not active
1 - 4000 Watt

Parameter 249: Enable/Disable Reporting on Set command

Using this parameter it is possible to enable/disable reporting after the set command (i.e. Basic set).
Size: 1 Byte, Default Value: 1

Setting Description
0 disable reporting
1 enable reporting

Technical Data

Dimensions 43 x 52 x 75 mm
Weight 80 gr
Hardware Platform ZM5101
EAN 3830062071505
IP Class IP 20
Voltage 230 V
Load 16A
Device Type On/Off Power Switch
Generic Device Class Binary Switch
Specific Device Class Binary Power Switch
Firmware Version 02.00
Z-Wave Version 04.21
Certification ID ZC10-18116325
Z-Wave Product Id 0x0159.0x0002.0x0054
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeOn/Off Power Switch