Quickstart

This is a Multiposition Motor Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.

A short push on the "LEARN" button confirms Inclusion and Exclusion. This button also issues a Node Information Frame.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The Hunter Douglas window blind control allows to control 24 DC motors of window blinds. The control is performed with polarity reversal, which makes this device suitable for a wide variety of window blind solutions among others Velux roof windows. Local operation is possible using two buttons.

Installation

The device requires an external power supply for 24 V DC with a minimum power of 12 W. Connect the two wires from the power supply in the right polarity with the terminals DC+ and DC-. The two wires from the DC Motor are connected to the terminals "Motor". It is recommended but not required to fix the device to a wall or a wall box using the two mounting holes on the enclosure side.

Calibration

To calibrate the traveling time of the blind a calibration process needs to be started right after installation. Keep the two buttons "OPEN" and "CLOSE" pushed for 10 seconds until the green motor LED shines. Now release the two buttons. Hit the "CLOSE" button to start the calibration sequence. The blind will now move between the end positions to detect the travel time.

Product Usage

The device is designed to control blind motors wirelessly. A local operation for tests is possible using the two buttons "OPEN" and "CLOSE".

Reset to factory default XXXResetDescription
Inclusion

A short push on the "LEARN" button confirms Inclusion and Exclusion.

Exclusion

A short push on the "LEARN" button confirms Inclusion and Exclusion.

NIF short push on the LEARN button
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Configuration Parameters

Parameter 1: Calibration

Starts the calibration sequence (1 = start)
Size: 1 Byte, Default Value: 00

Setting Description
00 Normal
01 Calibrate Command

Parameter 2: Motor Direction

Defines the direction of the motor and starts calibration sequence
Size: 1 Byte, Default Value: 00

Setting Description
00 normal
01 reverse

Parameter 3: Tilt Feature

Allows precision positioning for wood blinds
Size: 1 Byte, Default Value: 00

Setting Description
00 Disable
01 Enable

Technical Data

Dimensions 0.0000000x0.0000000x0.0000000 mm
Hardware Platform ZM3102
Voltage 24 V
Device Type Window Covering No Position/Endpoint
Generic Device Class Multilevel Switch
Specific Device Class Multiposition Motor Switch
Firmware Version 02.01
Z-Wave Version 02.28
Certification ID ZC08-09050004
Z-Wave Product Id 0033.5250.3032
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeWindow Covering No Position/Endpoint