Quickstart

This is a Notification Sensor for XXXQFrequencyName. To run this device please insert fresh 1 * CR123A batteries. To run this device please make sure the internal battery is fully charged. - Press the Network Button 3 times within 1.5s, the green LED is Blinking 3 times within 1 second.
- If Inclusion Process is successful, Green LED will turn off.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The smart carbon monoxide sensor detects CO, and sends alarm signals to alert people of the danger.When the smart carbon monoxidesensor detects CO, it will send an alarm notification to the gateway through wireless Z-Wave communication protocol, then the gateway sends the notification to server, the server interprets the signal and transfers the signal to users‘ APP. The smart carbon monoxide sensor has high stability and sensitivity,which will protect house from CO poisoning effectively.

Installation

To increase safety factors in single-layer house, suggest to install at least a sensor in each bedroom and install a sensor at 6m from  chimney and gas fixture.
To increase safety factors in multi-layer house, suggests to install at least a sensor in each bedroom, install at least one sensor in basement. Please install a sensor at 6m from chimney and gas fixture.


Anticlockwise rotating the bracket out from the installation base, then remove the battery insuating strip to make detector on power.


Screw the sensor into bracket, please remove the double - sided adhesive membrane on the installation base, and stick on the wall.

Product Usage


Inclusion / Exclusion / Reset



Battery Report

-  Battery Report is transmitted when power on the device.
-  Battery Report is transmitted once a day.
-  Battery Report is transmitted when the battery falls less than 10%

 

Battery Voltage
Battery Level
2.6V ~ 3.0V
10 ~ 100 (%)
Under 2,6V 
0xFF

 

Indicate LED statues description

Status
LED status
Alarm sound
Preheat
Green LED, red LED, yellow LED flash alternately
        No sound
Normal
Green LED flash 1 time every 53 seconds
        No sound
Test mode
Green LED, red LED, yellow LED and green LED flash alternately
?Di-Di-Di-Di?sound loudly
Alarm
Red LED flash 4 times every 10 seconds
?Di-Di-Di-Di?sound loudly
Low battery
Yellow LED flash 1 time every 53 seconds
 ?Di? sound every 53 seconds
Fault
Yellow LED flash 2 times every 10 seconds
?Di? sound twice every 10 seconds

How to replace the batteries


 

 

 Turn right to dismantle the mounting base of the device

 

 

 

1)take out battery from the device

2)Insert the battery into the device

( You must be careful of the battery polarity)

Turn left to install the mounting base of the device

(before install the mounting base, you should must insert battery firstly, otherwise the mounting base will not be fixed)

Reset to factory default - Long press Network Button while installing batteries in HS1CA-Z.
- Device Reset Locally notification is Transmitted.
Inclusion - Press the Network Button 3 times within 1.5s, the green LED is Blinking 3 times within 1 second.
- If Inclusion Process is successful, Green LED will turn off.
Exclusion - Press the Network Button 3 times within 1.5s
- If Exclusion Process is successful, Green LED is Blinking 6 times, then turn off.
NIF XXXNIF
Wakeup - Wake up Notification is transmitted every 24 hours by default.
- Wake up Notification is transmitted after Notification Report is Transmitted
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Lifeline: Include command classes: Battery report, Notification report, and Device Reset Locally notification, Binary report.
2 5 Root Device: Binary Sensor Command Class: Compatible with 300 series1 -Binary Sensor reports status of CO or no CO via Lifeline.2-When the sensor detects status change of CO and no CO, the device will be triggered.
3 5 Root Device: Notification reports status of detect CO or no CO via Lifeline.2-When the sensor detects status change of CO and no CO, the device will be triggered.

Technical Data

Dimensions 0.0790000x0.0790000x0.0790000 mm
Weight 46.5 gr
Hardware Platform ZM5202
EAN 6971348970055
IP Class IP 20
Voltage 3V
Battery Type 1 * CR123A
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Z-Wave Version 6.51.08
Certification ID ZC10-16095241
Z-Wave Product Id 0x0260.0x8005.0x1000
Communications Connections Ethernet (Wireless/WiFi)
Outdoor Use ok
Firmware Updatable Not Updatable
Communications Protocol Z-Wave Serial API
Color White
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeNotification Sensor