This is a
Reset to factory default | Press and hold the Z-button for more than 20 seconds. |
Inclusion | Click the Z-button once or triple click the Z-button quickly, the LED indicator should blink fast in blue. |
Exclusion | Click the Z-button once or triple click the Z-button quickly, the LED indicator should blink fast in orange. |
NIF | XXXNIF |
Wakeup | Press Z-Button |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline |
2 | 5 | On/Off Control -- Note parameter 14 |
Flood sensor can send BASIC SET command to nodes associated with group 2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Flood sensor can reverse its value of BASIC SET when flooding is triggered. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Send BASIC SET VALUE = 255 to nodes associated with group 2 when flooding alarm is triggered. Send BASIC SET VALUE = 0 to nodes associated with group 2 when flooding alarm is canceled. |
1 | Send BASIC SET VALUE = 0 to nodes associated with group 2 when flooding alarm is triggered. Send BASIC SET VALUE = 255 to nodes associated with group 2 when flooding alarm is canceled. |
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
The sensor measure the temperaure every ten minutes, change of 1 degree Celsius will be reported. By default, it must report at least once a day. Size: 1 Byte, Default Value: 144
Setting | Description |
---|---|
3 - 240 | Report time |
Size: 2 Byte, Default Value: 400
Setting | Description |
---|---|
-550 - 1250 | - 55 - +125°C |
Size: 0 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
-550 - 1250 | -55 - +125°C |
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
This parameter defines a battery level as the “low battery”. Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
10 - 50 | % |
Dimensions | 0.0680000x0.0250000x0.0680000 mm |
Weight | 34 gr |
Hardware Platform | ZM5101 |
EAN | 6925312930026 |
IP Class | IP 20 |
Voltage | 3,6V |
Device Type | Water Sensor |
Network Operation | Sleeping device |
Firmware Version | 01.02 |
Z-Wave Version | 04.3d |
Certification ID | ZC10-17125894 |
Z-Wave Product Id | 0x0208.0x0200.0x000f |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |