This is a
2) Place the device within the direct range of your Z-Wave controller.
3) Set the main controller in add mode (see the controller’s manual).
4) Click the Z-button once or triple click the Z-button quickly, the LED indicator should blink fast.
5) Wait for the adding process to end.
6) Successful adding will be confirmed by the Z-Wave controllers message.
Motion sensor can be included and operated in any Z-Wave network with other Z-Wave certified devices. This device supports security 0 and security 2 protected mode with AES-128 encryption.
Turn the cover counter-clockwise and open it.
Remove the battery blocker.
Reset to factory default | Press and hold the Z button for more than 20 seconds. If holding time more than 20seconds, the LED indicator will keep on for 2 seconds, which means resetting is complete. |
Inclusion | Click the Z-button once or triple click the Z-button quickly, the LED indicator should blink fast. |
Exclusion | Triple click the Z-button quickly, the LED indicator should blink fast. |
NIF | XXXNIF |
Wakeup | Press and hold the Z button for more than 5 seconds and release. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
2 | 5 | Basic Set - Motion Sensor will send Basic Set to associated nodes when the PIR is triggered. |
The higher the value, the more sensitive the PIR sensor. Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
0 | Disable |
1 - 8 | The higher the value, the more sensitive the PIR sensor. |
Motion sensor can send BASIC SET command to nodes associated with group 2 when motion is triggered. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Motion Sensor can reverse its value of BASIC SET when motion is triggered. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Send BASIC SET VALUE = 255 to nodes associated with group 2 when motion alarm is triggered. Send BASIC SET VALUE = 0 to nodes associated with group 2 when motion alarm is canceled. |
1 | Send BASIC SET VALUE = 0 to nodes associated with group 2 when motion alarm is triggered. Send BASIC SET VALUE = 255 to nodes associated with group 2 when motion alarm is canceled. |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | the product will not sends a vibration alarm after moving or shaking |
1 | the product will sends a vibration alarm after moving or shaking |
Motion alarm will be cancelled in the main controller after 3 seconds, the alarm cancellation can be delay by this parameter. Any motion detected during the cancellation delay time countdown will result in the countdown being restarted. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reports are not sent |
1 - 65535 | the change in luminance level resulting in luminance report being sent to the main controller. |
Define a battery level as the clow battery. Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
10 - 50 | The low level from 10% to 50% |
Dimensions | 50 x 50 x 50 mm |
Weight | 48.1 gr |
Hardware Platform | ZM5101 |
EAN | 6925312929068 |
IP Class | IP 20 |
Voltage | 3V |
Battery Type | 1 * CR123A |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-17115833 |
Z-Wave Product Id | 0x0208.0x0200.0x0012 |
Sensors | Motion/No Motion (Binary) |
Firmware Updatable | Updatable by Consumer by RF |
Color | White |
Supported Notification Types | Home Security |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |