Quickstart

This is a secure Wall Controller for XXXQFrequencyName. To run this device please insert fresh 1 * LIR2450 batteries. To run this device please make sure the internal battery is fully charged. 1. Insert the LIR2450 battery.
2. Set the Z-Wave network main controller into learning mode( see Z-Waave network controller operating manul).
3. Triple click the Z-button.
4. If the inclusion is successful, the LED will blink in blue less than for 5 seconds and then keep on for 15 seconds.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The Scene Controller is a wireless, portable and rechargeable scene switch. It can control a Z-Wave device, such as smart plug, smart dimmer with a Z-Wave gateway. You can also activate a scene like sleep scene, movie scene and entertainment scene with it.

Installation

Open the cover, as the figure beows shows.


Insert your battery and close the cover, as the figure below shows.

Product Usage

LOW BATTERY ALARM FUNCTION

If the battery level of the Scene Controller is less than 20%, the Scene Controller will sound 3 times when the button is pressed.

COMMUNICATION FAILURE ALARM FUNCTION

The Scene Controller will sound one time when the communication between the Scene Controller and any one of the controlled device is failed.

TESTING Z-WAVE NETWORK RANGE

Scene Controller’s LED indicator can signal its communication quality with the Z-Wave main controller.

To start testing:
Press and hold the Z-button for 11 to 15 seconds, the LED will keep on in purple for 3 seconds, it will enter testing mode if you short press the Z-button during these 3 seconds. 

Blink in green –Scene Controller establish a direct communication with the main controller, and still under checking.
Keep green – The green light should last about 2 seconds, which means the direct communication is stable.
Blink in orange –Scene Controller can communicate with the main controller in intermediate radio transmit power level, and still under checking.
Keep orange – The communication quality is moderate.
Keep Red – The communication is failed.

BATTERY CHARGING

Scene Controller has an internal rechargeable battery that will run for half a year under the normal use condition. If the battery level is less than 20%, this will activate the low battery level function, this means you need to charge the battery.
The charger’s output should be a micro USB terminal with the specification of output DC 5V. The LED nearby the micro USB port will keep on in red during the changing, and it will turn to green.




Reset to factory default Pressing and holding the Z-button for 20 seconds. Release the button after 20 seconds, LED will keep in yellow for 3 seconds. Scene Controller will be reset to factory defaults if you short press the button within this 3 seconds.
Inclusion Non-secure: Triple click the Z-button.

Secure: Pressing and holding the Z-button for 3 seconds.
Exclusion Triple click the Z-button, if the exclusion is successful, LED will blink in orange for less than 5 seconds and then keep on for 3 seconds.
NIF XXXNIF
Wakeup Pressing and holding Z-Button for 3 seconds. Led will turn to green, which means Scene Controller has been woken up.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Scene Controller will send Scene Controller sends the central scene notification command and battery report command to the associated nodes.
2 5 Scene Controller will send Basic Set command to the associated nodes.
3 5 Scene Controller will send switch multilevel set, the multilevel start level change and multilevel stop level change command to the associated nodes.

Configuration Parameters

Parameter 254: Enable/disable the configuration command

Lock/unlock all configuration parameters.
Size: 1 Byte, Default Value: 0

Setting Description
0 Unlock all configuration parameters.
1 Lock all configuration parameters

Parameter 255: Reset Scene Controller

Reset Scene Controller and remove from the Z-Wave network
Size: 4 Byte, Default Value: 0

Setting Description
1431655765 Reset Scene Controller and remove from the Z-Wave network

Technical Data

Dimensions 0.0500000x0.0160000x0.0500000 mm
Weight 18.63 gr
Hardware Platform ZM5101
EAN 6925312929075
IP Class IP 20
Voltage 3V
Battery Type 1 * LIR2450
Device Type Wall Controller
Network Operation Portable Slave
Z-Wave Version 6.51.08
Certification ID ZC10-16085175
Z-Wave Product Id 0x0208.0x0200.0x0009
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeWall Controller