Quickstart

This is a Valve - Open/Close for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
To enter learn mode(inclusion), press UP arrow for 5 seconds while the valve is open.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

TIMEVALVE SMART helps users easily check and turn off the gas valves in home from anywhere. It detects dangerous temperature and alerts potential danger situations so that users can handle a problem. In addition, users can set time to lock gas valves against danger.

Reset to factory default To reset, Press DOWN arrow for 5 seconds while the valve is open.Please use this procedure only in the event that the network primary controller is missing or otherwise inoperable.
Inclusion To enter learn mode(inclusion), press UP arrow for 5 seconds while the valve is open.
Exclusion To enter learn mode(exclusion), press UP arrow for 5 seconds while the valve is open.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 1: Default Timeout

Valve Default Timeout in seconds
Size: 4 Byte, Default Value: 2400

Setting Description
300 - 2400 Valve Default Timeout in seconds

Parameter 100: Valve report interval

periodic valve state report interval in seconds
Size: 4 Byte, Default Value: 86400

Setting Description
600 - 16777215 periodic valve state report interval in seconds

Parameter 3: Remaining Time

Remaining Time to Close in seconds
Size: 4 Byte, Default Value: 2400

Setting Description
0 - 35400 Remaining Time to Close in seconds

Technical Data

Hardware Platform ZM5101
Device Type Valve - Open/Close
Network Operation Listening Sleeping Slave
Firmware Version 01
Z-Wave Version 6.51.06
Certification ID ZC10-15050010
Z-Wave Product Id 0x022A.0x0100.0x0100
Frequency XXfrequency
Maximum transmission power XXantenna
South KoreaValve - Open/Close