Quickstart

This is a Specific Device Class not used for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
How to Add the Leak Gopher Z-Wave Valve Control to your Z-Wave Controller-Plug the wall cube power adapter (included) into the receptacle on the bottom of the Leak Gopher Z-Wave Valve Control marked 3.6 VDC. Plug the wall cube into a 110 VAC outlet. This provides power to the Leak Gopher Z-Wave Valve Control.-Configure the Z-Wave Controller to Add a device. -When the Z-Wave Controller is ready to add a device, it will display a message like waiting to add device. Press Add button on the device-The Add/Remove button is located on the side of the Leak Gopher Z-Wave Valve Control. Press the Add/Remove button.-The Z-Wave Controller will acknowledge that the Leak Gopher Z-Wave Valve Control had been added to the Z-Wave network.-Your Leak Gopher Z-Wave Valve Control is ready to use.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The Leak Gopher Z-Wave Valve Controller is a professionall grade Z-Wave Device that allows the water to your home or business to be automatically turned off when water is detected by water sensors connected to any Z-Wave capable controller. The Leak Gopher Z-Wave Valve Controller is Z-Wave Plus compliant allowing you to use all of the functionality and programmability built into the new, Z-Wave Plus Controllers. It comes with a Stainless Steel Electronic Ball Valve.Design and Operation of The Leak Gopher Valve ControllerSimply install the stainless steel Electronic Ball Valve on theorwater line where water enters your home or business, attach it to the Leak Gopher by plugging in the RJ-11 telephone jack, and tell your Z-Wave controller about the Leak Gopher and your home or business is protected. Standard telephone wires and connectors can be used to extend the Ball Valves wire so it is easy to locate the Electronic Ball Valve where you need it to be, and still have easy access to the Leak Gopher Z-Wave Valve Controller. When any of your water sensors get wet, your Z-Wave Controller will tell the Leak Gopher to turn the water off and Voil! No Flood!A fully capable Z-Wave device, you can also program scenes that allow your Leak Gopher to turn the water off when you leave home and arm your security system and back on when you get home. No more worries about your house flooding while you are away.Also, for your convenience and piece of mind, there are two buttons on the Leak Gopher that allow you to instantly turn your water off and on. No more looking for that water key and digging in the yard looking for your water meter!

Reset to factory default How to reset the Leak Gopher Z-Wave Valve Control.-To reset the Leak Gopher Z-Wave Valve Control Z-Wave radio and routing table, press and hold the Add/Remove button located on the side of the Leak Gopher Z-Wave Valve Control for 15 seconds.
Inclusion How to Add the Leak Gopher Z-Wave Valve Control to your Z-Wave Controller-Plug the wall cube power adapter (included) into the receptacle on the bottom of the Leak Gopher Z-Wave Valve Control marked 3.6 VDC. Plug the wall cube into a 110 VAC outlet. This provides power to the Leak Gopher Z-Wave Valve Control.-Configure the Z-Wave Controller to Add a device. -When the Z-Wave Controller is ready to add a device, it will display a message like waiting to add device. Press Add button on the device-The Add/Remove button is located on the side of the Leak Gopher Z-Wave Valve Control. Press the Add/Remove button.-The Z-Wave Controller will acknowledge that the Leak Gopher Z-Wave Valve Control had been added to the Z-Wave network.-Your Leak Gopher Z-Wave Valve Control is ready to use.
Exclusion How to Remove the Leak Gopher Z-Wave Valve Control to your Z-Wave Controller-Plug the wall cube power adapter (included) into the receptacle on the bottom of the Leak Gopher Z-Wave Valve Control marked 3.6 VDC. Plug the wall cube into a 110 VAC outlet. This provides power to the Leak Gopher Z-Wave Valve Control.-Configure the Z-Wave Controller to Remove a device. -When the Z-Wave Controller is ready to Remove a device, it will display a message like waiting to remove device. Press remove button on the device-The Add/Remove button is located on the side of the Leak Gopher Z-Wave Valve Control. Press the Add/Remove button. -The Z-Wave Controller will acknowledge that the Leak Gopher Z-Wave Valve Control had been removed from the Z-Wave network.-Your Leak Gopher Z-Wave Valve Control is removed form this controller.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Lifeline group

Technical Data

Hardware Platform ZM5202
Device Type Valve - Open/Close
Generic Device Class Switch Binary
Specific Device Class Specific Device Class not used
Network Operation Always On Slave
Firmware Version 01
Z-Wave Version 6.51.00
Certification ID ZC10-14020001
Z-Wave Product Id 0x0173.0x0003.0x0002
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoValve - Open/Close