This is a
Shutter Panel Switch is a wall panel built-in with Z-Wave Plus module. With its stylish design and stable performance, the panel can be used to wire roller shutter which controlled by AC motor (with limit). It supports basic command class,multi channel command class and multi channel association command class, also works as a repeater in a Z-Wave network. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from any other manufacturers.
Reset to factory default | Press 10 times of UP or DOWN button or exclude the device from Z-Wave network, then cut off the main power. The factory setting will be restored. |
Inclusion | 1. Power the panel on, if LEDs flick 4 times, it shows the device is not in any Z-Wave network. If LEDs turns to orange directly, the panel is in a network already.
2. Set controller into Include/Exclude mode, and press 8 seconds or 3 clicks on "UP" or "DOWN" button to add/remove. If succeed, green LED flicks 4 times. |
Exclusion | 1. Power the panel on, if LEDs flick 4 times, it shows the device is not in any Z-Wave network. If LEDs turns to orange directly, the panel is in a network already.
2. Set controller into Include/Exclude mode, and press 8 seconds or 3 clicks on "UP" or "DOWN" button to add/remove. If succeed, green LED flicks 4 times. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline |
Size: 2 Byte, Default Value: 720
Setting | Description |
---|---|
1 - 32767 | Unit 5sec 5*720S=3600S= 1hour |
Size: 2 Byte, Default Value: 6
Setting | Description |
---|---|
1 - 32767 | Unit 10min 6*10min=1 hour |
Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
1 | Report destination level in 5s period when requested by the gateway; And then report current level after 5s. |
2 | Report every 10% level change while running |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | activate demo trip only |
Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | LED disabled |
1 - 10 | Min level-Max level |
11 - 255 | same level as 10 |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | activate demo trip and calibration |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | activate calibration |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 98 | in % |
Size: 1 Byte, Default Value: 99
Setting | Description |
---|---|
1 - 99 | in % |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
85 | Factory Reset |
Dimensions | 0.0860000x0.0860000x0.0410000 mm |
Weight | 165 gr |
Hardware Platform | ZM5202 |
EAN | 6928954215001 |
IP Class | IP 20 |
Voltage | 230 V |
Load | 2x 3,5 A |
Device Type | Roller Shutter |
Generic Device Class | Multilevel Switch |
Specific Device Class | Motor Control Device (C) |
Firmware Version | 03.03 |
Z-Wave Version | 04.3e |
Z-Wave Product Id | 0x015f.0xc421.0x5102 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |