This is a
The MCOHome PM2.5 Monitor is an air quality controller which is compatible with Z-Wave technology, it is mainly used to monitor PM2.5 concentration. To protect yourself and others from danger and to protect the device from damage, please read the safety information before using it. You can find further information in the device manual.
Pay attention to the current direction of positive and negative, otherwise device will easily be burn!
Step 1: Follow the wiring diagram to insert all wires into right terminals and tighten screws.
Step 2: Separate panel and bottom case by removing the screw at the bottom of device, and mount the bottom case onto wall with two screws (M4*25mm). The hole pitch 60mm is for 86/60mm box, and 82mm is for American 120mm box.
Step 3: Mount the panel back by aligning its tabs and card slot onto the bottom case.
Step 4: Tighten the fastening screw and the device is ready for normal work.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
The MCOHome PM2.5 Monitor is an air quality controller which is compatible with Z-Wave technology, it is mainly used to monitor PM2.5 concentration in industrial, agricultural, and residence environment, while monitoring the indoor temperature and humidity. Device can be included into any Z-Wave network, and is compatible with any other Z-Wave certified devices.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
Location:
Device is suggested to be installed indoor, a place with around 1.5m height above the floor where represents the average PM2.5 concentration. It should be away from direct sunlight, any cover, or any heat source, to avoid false signal for detection.
CAUTION: Cut off power supply at circuit breaker or fuse before installation to avoid fire, shock or death!
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Including and Excluding of Z-Wave network
Activate Inclusion/Exclusion mode in the gateway. When device powered on, long press S1 and S3 synchronically to enter interface for inclusion or exclusion of Z-Wave network. If device has not been included into any Z-Wave network before, (- - -) will display on the screen. Then press S1 once, (- - -) flashing and device enters into learning mode to get a node ID. If inclusion is success, a node ID will display on the screen. If not, (- - -) will stop flashing in 20 sec. If a node ID displays, it means the device is already in a Z-Wave network. To press S1 once can remove it from the network. (- - -) displays and press S2 once can return to normal work. Note: If display flashing, long press S1+S3 can quite the operation and back to normal work. If display stops flashing, press S2 once can return to normal work.
Including and Excluding of Z-Wave network
Activate Inclusion/Exclusion mode in the gateway. When device powered on, long press S1 and S3 synchronically to enter interface for inclusion or exclusion of Z-Wave network. If device has not been included into any Z-Wave network before, (- - -) will display on the screen. Then press S1 once, (- - -) flashing and device enters into learning mode to get a node ID. If inclusion is success, a node ID will display on the screen. If not, (- - -) will stop flashing in 20 sec. If a node ID displays, it means the device is already in a Z-Wave network. To press S1 once can remove it from the network. (- - -) displays and press S2 once can return to normal work. Note: If display flashing, long press S1+S3 can quite the operation and back to normal work. If display stops flashing, press S2 once can return to normal work.
Button and Display
Local Time Setting
In normal display interface, long press S3 will enter the local time modification interface. Press S2 can switch among "Week, Hour and Minute ", press S1 or S3 can change their values. After all parameters set, press S2 can save settings and return to normal display.
Backlight
The backlight will be full bright when any keys pressed, and turn to half bright if no operation in 10 Sec.
You can find further information in the device manual.
Specification
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline |
Dimensions | 0.0860000x0.1350000x0.0330000 mm |
Weight | 260 gr |
EAN | 6928954202407 |
Device Type | Routing Multilevel Sensor |
Generic Device Class | Multilevel Sensor |
Specific Device Class | Routing Multilevel Sensor |
Firmware Version | 01.00 |
Z-Wave Version | 03.43 |
Z-Wave Product Id | 015f.0a05.0201 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |