You can find further information in the device manual.Step 1: Separate the device into two parts: the display panel and the bottom.
Step 2: Insert all wires into the right terminals and tighten screws. Wiring diagrams are shown below.
Step 3: Push the bottom into the junction box and secure it with two screws, and then mount the touch panel back.
Step 4: Confirm the device is well mounted, power on and it is ready to operate.
MCOHome Water Heating Thermostat is a Z-Wave enabled device for indoor temperature control. MH7-WH-EU is mainly applied to control wall mounted boiler, water valve/pump etc. , while MH7-EH-EU for electrical heating system. The device is of high reliability and practicability. And can be included and operated in any Z-Wave network with other Z-Wave certified devices from any other manufacturers.
Location:
Thermostat is suggested to be installed indoor, a place with around 1.5m height above the floor where represents the average room temperature. It should be away from direct sunlight, any cover, or any heat source, to avoid false signal for temperature control.
CAUTION: Cut off power supply at circuit breaker or fuse before installation to avoid fire, shock or death!
On/Off Setting
When power on, thermostat displays (OFF), all outputs are forced off. Touch S3 button to enter normal display. Device displays current week, local time, working mode, the current temperature, output status etc.
Local Time Setting
In normal working interface, long press S1 to enter the local time setting interface. In local time setting interface, press S3 key can switch among ?week, hour and minute?, and press S4 or S5 can set the value of the items. After finish local time setting, touch S1 or wait 8 seconds without any key operation will save the setting and return to normal display.
°C / °F setting
In normal operating interface, long press S2 button can switch between °C and °F.
Temperature setting
In normal operating interface, touch S4 or S5 can enter temperature setting. The setting range is 5-37C (41-98°F). Then press S4 or S5 can change value. Press S3 or wait 8 seconds without any key operation will save the setting and return to normal operation interface. Auto Mode: The changed value only valid in the current time period for this time, and device will follow default setting in following time periods. Manual Mode: The changed value will be valid until next manually setting. Vacation mode: The changed value will be valid until next setting.
Manual / Auto mode setting
Touch S3 can switch between Manual and Auto mode. Choose one and wait for 3 Sec can confirm the chose. Auto Mode: Device follows the default time periods and temperature to control heating system automatically. Manual Mode: Device follows the manually setting to control heating system.
You can find further information in the device manual.
Secret Menu
Reset to factory default | XXXResetDescription |
Inclusion | Under the shutdown state, press and hold S2 to enter interface for inclusion or exclusion of Z-Wave network. Before device included into network, ?- - -? will display on the screen. Then press S4 once, device will enter learning mode to get a node ID. If inclusion is success, a node ID will display on the screen in a few seconds. A node ID can always inform us whether the device is in the network or not. Note: Follow the same steps to exclude the device from the network. After inclusion, turn off the device and then turn it on. Now the device is ready to be operated by controller/ gateway in Z-Wave network. |
Exclusion | Under the shutdown state, press and hold S2 to enter interface for inclusion or exclusion of Z-Wave network. Before device included into network, ?- - -? will display on the screen. Then press S4 once, device will enter learning mode to get a node ID. If inclusion is success, a node ID will display on the screen in a few seconds. A node ID can always inform us whether the device is in the network or not. Note: Follow the same steps to exclude the device from the network. After inclusion, turn off the device and then turn it on. Now the device is ready to be operated by controller/ gateway in Z-Wave network.
|
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline |
Dimensions | 86x86x43 mm |
Weight | 190 gr |
IP Class | IP 20 |
Voltage | 230 V |
Load | 5A |
Device Type | Thermotat |
Firmware Version | 02.00 |
Z-Wave Version | 03.43 |
Z-Wave Product Id | 0x015f.0x0702.0x3102 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |