Quickstart

This is a Routing Multilevel Sensor for XXXQFrequencyName. To run this device please connect it to your mains power supply.

MCOHome CO2 Monitor is an air quality detector which is compatible with Z-Wave technology, it is mainly used to monitor CO2 concentration.

To protect yourself and others from danger and to protect the device from damage, please read the safety information before using it.

You can find further information in the device manual.

    Step 1: Separate Panel and Bottom case by removing the screw at the bottom of device. Insert all wires into the right terminals and tighten screws. The wiring diagram is shown below.
Pay attention to the current direction of positive and negative, otherwise device will easily be burn!
    Step 2: Mount the Bottom case onto wall with two screws (M4*25mm).The hole pitch 60mm is for 86/60mm box, and 82mm is for American 120mm box.
    Step 3: Mount the Panel back by aligning its tabs and card slot onto the Bottom case.
    Step 4: Tighten the fastening screw and the device is ready for normal work.


Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

MCOHome CO2 Monitor is an air quality detector which compatible with Z-Wave technology, it is mainly used to monitor CO2 concentration in industrial, agricultural, and residence environment, while monitoring the indoor temperature, humidity and VOC air quality. Device can be included into any Z-Wave network, and is compatible with any other Z-Wave certified devices.

Installation

Location:

Device is suggested to be installed indoor, a place with around 1.5m height above the floor where represents the average CO2 concentration. It should be away from direct sunlight, any cover, or any heat source, to avoid false signal for temperature control.




1. Device must be wall-mounted vertically. Do not lay it flat or upside down while working.
2. Do not mounted it in a wind gap, or cover its bottom, which may affect the detected data.

Step 1: Separate Panel and Bottom case by removing the screw at the bottom of device. Insert all wires into the right terminals and tighten screws. The wiring diagram is shown above.

Step 2:Mount the Bottom case onto wall with two screws (M4*25mm).The hole pitch 60mm is for 86/60mm box, and 82mm is for American 120mm box.

Step 3: Mount the Panel back by aligning its tabs and card slot onto the Bottom case.

Step 4: Tighten the fastening screw and the device is ready for normal work.

 

Product Usage

Button and Display

    Long press K2 3Sec to check the Node ID
    Long press K1 3Sec to modify the local time

Local Time Setting

In normal display interface, long press K1 will enter the local time modification interface.

    Week - starts flashing, press K2 can switch among MON-TUE-WED-THU-FRI-SAT-SUN. Choose one then press K1 will save the setting.
    Hour - starts flashing. Press K2, the value will cycle switchover from 00-23. Press K1 to save the change.
    Minute - starts flashing. Press K2, the value will cycle switchover from 00-59. Then press K1 can save settings and return to normal display.

In the process of modification, long press K1 can save and return to the normal interface, long press K2 can continuously increase the value.

VOC detection (optional)

Device has built-in a VOC sensor, and four levels can be detected and shown on the display: ExcellentGoodAverage and Poor. (VOC toxic gases include carbon monoxide, alcohol, hydrogen, methane, isobutene, ammonia and benzene, etc.)

You can find further information in the device manual.

Specification

  • Power Supply: AC 220V
  • CO2 display range: 0-2000ppm
  • Default threshold: 1000ppm (adjustable)
  • Temperature range: -9.0~50 °C
  • Humidity range: 0%-99%RH
  • Installation: Wall-mounted (Vertical)
  • Work environment: -10~+8°C 0-90%RH(Non-condensation)
  • Dimension: 90* 130*28mm
  • Hole Pitch: 60mm or 82mm
  • Housing: Tempered glass+ PC Alloy

Reset to factory default XXXResetDescription
Inclusion

Including and Excluding of Z-Wave network

Activate Inclusion/Exclusion mode in the gateway. When device is powered on, long press K2 can enter interface for inclusion or exclusion of Z-Wave network. If device has not been included into any Z-Wave network before, - - - will display on the screen. Then press K2 once, - - - flashing and device enters into learning mode to get a node ID. If inclusion is success, a node ID will display on the screen. If not, - - - will stop flashing in 20 sec. If a node ID displays, it means the device is already in a Z-Wave network. To press K2 once can remove it from the network. - - - displays and press K1 once can return to normal work.

Exclusion

Including and Excluding of Z-Wave network

Activate Inclusion/Exclusion mode in the gateway. When device is powered on, long press K2 can enter interface for inclusion or exclusion of Z-Wave network. If device has not been included into any Z-Wave network before, - - - will display on the screen. Then press K2 once, - - - flashing and device enters into learning mode to get a node ID. If inclusion is success, a node ID will display on the screen. If not, - - - will stop flashing in 20 sec. If a node ID displays, it means the device is already in a Z-Wave network. To press K2 once can remove it from the network. - - - displays and press K1 once can return to normal work.

NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Lifeline
Note: For “Notification” purpose, device works in “Push” mode in “Notification Command Class”. Use “Configuration “can set the threshold of CO2 Notification report. When detected value is more than setting value, device will send (CO2 Detected Event) report to the Group 1. And this report will keep sending in every 30 sec unless the detected value lower than setting value. Use “Notification Set” can set this unsolicited report; this function is default as “OFF”.

Configuration Parameters

Parameter 1: CO2 threshold value


Size: 2 Byte, Default Value: 1000

Setting Description
1 - 2000 Value in PPM

Parameter 2: CO2 report interval

Since Firmware V2.2
Size: 1 Byte, Default Value: 10

Setting Description
0 Disable
10 - 255 Value x 5ppm

Parameter 3: Temperature report interval

Since Firmware V2.2 
Size: 1 Byte, Default Value: 1

Setting Description
0 Disable
1 - 255 Value x 0,5°C

Parameter 4: Humidity report interval

Since Firmware V2.2
Size: 1 Byte, Default Value: 2

Setting Description
0 Disable
2 - 99 Value in %

Parameter 255: Factory setting

Since Firmware V2.2
Size: 1 Byte, Default Value: 0

Setting Description
85 Restore the factory setting(write only)

Technical Data

Dimensions 0.0900000x0.1300000x0.0526900 mm
Weight 310.72 gr
Hardware Platform ZM5101
EAN 6928954202100
IP Class IP 21
Voltage 230V
Device Type Routing Multilevel Sensor
Generic Device Class Multilevel Sensor
Specific Device Class Routing Multilevel Sensor
Firmware Version 02.02
Z-Wave Version 04.21
Z-Wave Product Id 015f.0901.5102
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeRouting Multilevel Sensor