Quickstart

This is a Binary Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.

To include or exclude the device you only need to press and hold any key for 3 seconds.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The MCO_TPS314 is a glass-surface wireless actuator able to to switch 4 separate oads up to 1100 W. It is designed for application in UK Pattress boxes (according to British Standard). Beside local switching the device can be used to control four groups of directly associated devices or scenes stored in the central controller. A blue LED on every button indicates the switching status. The installation of the device requires a 3 wire system with neutral wire.

Installation

Caution: The device is for British standard socket!

Important
: Please make sure you have cut off power supply before you start to install the Panel.

  • Connect Hot Line to "L"
  • Connect Neutral Line to "N"
  • Connect Load wire to "1-4"

  1. Remove the steel frame from the device, and secure it onto the junctions box with tow screws.
  2. Insert all wires into the right terminals and tighten screws.
  3. Attach the wired device on "A" points of the steel frame as shown first, and then push the whole device into junction box.
  4. Confirm the device is well mounted, power on and it is ready to operate.

Product Usage

The actuator is operated by the local switching Touch pannels or wirelessly using Z-Wave commands.

Reset to factory default
  • Press and hold any key on the panel for 10 seconds for restoring factory settings. 
  • Then the node information and association data will be deleted.
Noteï¼ÂÂÂÂÂÂ?If factory settings are restored, all INDICATION LEDs on the panel will turn orange, and all switches will turn off.
Inclusion

To include the device you only need to press and hold any key for 8 seconds.

Exclusion

To exclude the device you only need to press and hold any key for 8 seconds.

NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Switch Button Group 1
2 5 Switch Button Group 2
3 5 Switch Button Group 3
4 5 Switch Button Group 4
5 1 This group supports one node, which defaults to controller node.

Technical Data

Dimensions 0.0860000x0.0860000x0.0340000 mm
Weight 190 gr
IP Class IP IP20
Voltage 230 V
Load 1150 W
Device Type Touch Panal Switch
Generic Device Class Binary Switch
Specific Device Class Binary Power Switch
Firmware Version 01.00
Z-Wave Version 03.67
Certification ID ZC08-14080012
Z-Wave Product Id 0x015f.0x0000.0x0000
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeTouch Panal Switch