Quickstart

This is a On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1.Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. 2.Pressing On/Off button three times within 2 seconds will enter inclusionmode on the switch.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

This plug-in ON/OFF switch Home Control Metering Plug is a security enabled wireless switch, based on Z-Wave Plus technology. Z-Wave Plus enabled devices displayingtheZ-Wave Plus logo can also be used with it regardless of the manufacturer, and can also be used in other manufacturers Z-Wave enabled networks. Remote On/Off control of the connected load is possible with other manufacturers wireless Controller. Each switch is designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the signal is received by itsintended destination by routing the signal around obstacles and radio dead spots. Because Home Control Metering Plug supports Security Command Class, it can be added with a Secured controller. Its functionality and supported command classes is identical when included as a secure and non-secure device. This plug-in ON/OFF switch is able to detect instance wattage (3000W/CE/CN,1500W/UL/TW/JP) and overload current (14.5A) of connected lights or appliances. When detecting overload state, the Switch will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, unplug and re-connect the switch will reset its overload condition to normal status.

Reset to factory default (Use this procedure only in the event that the primary controller is lost or otherwise inoperable.)1.Pressing On/Off button three times within 2 seconds will enter inclusion mode on the switch.2.Within 1 second, press On/Off button again for 5 seconds.
Inclusion 1.Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. 2.Pressing On/Off button three times within 2 seconds will enter inclusionmode on the switch.
Exclusion 1.Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. 2.Pressing On/Off button three times within 2 seconds will enter exclusionmode on the switch.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 1: Watt Meter Report Period

This configuration parameter determines how often meter reporting of instantaneous watt usage is reported automatically.Each unit is 5 seconds.The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr).
Size: 2 Byte, Default Value: 720

Setting Description
1 - 32767 Enable automatic interval reporting with an interval of 5 * the value.
0 Disable automatic interval meter reporting of Watts

Parameter 2: KWH Meter Report Period:

This parameter controls the frequency at which the kWh value of the meter is reported to the node in association group 1.This setting is in units of 10 minutes. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days).
Size: 2 Byte, Default Value: 6

Setting Description
1 - 32767 6*10 min=1 hour
0 Disable automatic interval meter kWh reporting.

Parameter 3: Threshold of current for Load Caution

This is a warning when the current of load over the preset threshold value, if the setting value is 1300, when the load current of Relay1 over this value, Home Control Metering Plug will send current meter report to warn the Group1 node, the Range of the setting value is from 10 to 1300,and the default value is 1300.
Size: 2 Byte, Default Value: 1300

Setting Description
10 - 1300 1300*0.01A = 13A

Parameter 4: Threshold of KWh for Load Caution

This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 over this value, Home Control Metering Plug will send KWH meter report to warn the Group1 node, minimum value is 1KWh and default value is 10000 kWh.
Size: 2 Byte, Default Value: 10000

Setting Description
1 - 10000 Enable automatic warning when the accumulated kWh power consumption exceeds the setting value from 1KWh ~ 10000KWh.
0 Disable kWh Load Caution Reporting

Parameter 5: Restore switch state mode

Whenever the AC power return from lost, Home Control Metering Plug will restore the switch state which could be SWITCH OFFLAST SWITCH STATESWITCH ON. The default setting is LAST SWITCH STATE.
Size: 1 Byte, Default Value: 1

Setting Description
0 Upon the return of AC power, the switch will remain Off.
1 Upon the return of AC power, the switch will return to the state it was in when the power was turned off.
2 Upon the return of AC power, the switch will turn On.

Parameter 6: Mode of switch off function

This configuration parameter determines how the switch will respond to a received SWITCH OFF command.
Size: 1 Byte, Default Value: 1

Setting Description
0 SWITCH OFF commands received are ignored.
1 SWITCH OFF commands received are honored.

Parameter 7: LED indication mode

This parameter determines the state of the LED display.
Size: 1 Byte, Default Value: 1

Setting Description
1 The LED follows the state of the switch.
2 Night Mode - When the switch is On, the LED is Off, and when the switch is Off, the LED is On.
3 Flash Mode - When the state of the switch changes, the LED will be on for one second and then will turn off.

Parameter 8: Auto off timer

Automatic Shut-Off Setting.This parameter determines the amount of time before the switch is automatically turned off after it has been turned on.
Size: 1 Byte, Default Value: 0

Setting Description
1 - 32767 1s ~ 32767s for automatically turning off
0 Disable the auto off function

Parameter 9: RF off command mode

This parameter determines how the switch responds to the receipt of a SWITCH_ALL_OFF command.
Size: 1 Byte, Default Value: 0

Setting Description
0 When SWITCH ALL OFF is received, the MT02646 turns Off.
1 When SWITCH ALL OFF is received, the MT02646 ignores the command and does nothing.
2 When SWITCH ALL OFF is received, the MT02646 will turn On if it is Off, and will turn Off if it is On.
3 When SWITCH ALL OFF is received, the MT02646 turns On.

Technical Data

Hardware Platform SD3502
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version 01
Z-Wave Version 6.51.00
Certification ID ZC10-14090006
Z-Wave Product Id 0x0175.0x0001.0x0011
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)On/Off Power Switch