Quickstart

This is a Motion Sensor for XXXQFrequencyName. To run this device please insert fresh 1 * CR123A batteries. To run this device please make sure the internal battery is fully charged.


1) Disassemble PIR main body and insert battery into PIR sensor. After making it powered on, please do not operate it within 20s.
2) Make sure PIR sensor is located within the Z-Wave network range of gateway.
3) Set Z-Wave gateway into inclusion mode (Refer to gateway user manual).
4) Press the code button in PIR sensor three times continuously, LED Color Indicator then PIR sensor will enter inclusion mode. Meanwhile, LED light would flash red color five times on and off alternately.
5) PIR will be detected and included in the Z-Wave network.
6) Wait for gateway to configure PIR sensor.


Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Motion sensor(PIR) is a passive infrared detector or physical sensor. This sensor doesn’t emit any energy but only passively receive and detect infrared radiation from outside. Under room temperature, all items have radiation. Human beings are warm-blooded animals with stable infrared radiation, so are most easily to be detected. That’s why we also call it body sensor. PIR send messages via Z-Wave network to Z-Wave gateway. In the Z-Wave network communications, PIR can be connected to any Z-Wave gateway. Different countries or areas, the radio frequency is different. In the communication between PIR and Z-Wave gatwway, PIR can only send messages, not be able to receive messages. When PIR is triggered, PIR will send message to Z-Wave gateway, and associate devices to work through ZWave gateway. PIR is battery powered, is small and can be installed easily.

Installation

Holder Installation

Fix the holder with screws and screw stopper or put the sticker on the bottom of motion sensor then fix it on the wall.



Battery Installation



1.Make sure PIR placed within the Z-Wave network range of gateway.
2.PIR is recommended to be fixed at the height of 2- 4 meters off the ground.
3.When install PIR, please keep it far away from places where air temperature changes sensitively, e.g., around air conditioners, refrigerators, stoves and so on. 
4.Furniture, large bonsai or other spacers shouldn’t be placed within PIR’s detection area.
5.When installing PIR, please keep it away from stairs, elevators and other obstructions. Make sure these obstructions are outside of PIR’s detection area.
6.After instaling PIR, please test whether PIR works properly or not, if there is false alarm from PIR, please install PIR in another place.
7.Direct association can be allowed between PIR and other ZWave network devices if preset association functionality. Z-Wave gateway will not take part in such communication. Using this mechanism, PIR can communicate with other devices even when gateway is damaged.

Detection Range

PIR has to be installed in a corner of room or perpendicularly to door. Actual detection range of this sensor can be influenced by environment conditions. If there are false alarms reported, check if there are any moving objects within sensor‘s detection
area, such as trees blowing in the wind, cars passing by, windmills. False motion alarms may be caused by masses of moving air and heat as well. If sensor keeps on reporting false alarms, despite eliminating all of above-mentioned factors, then install sensor in another place.

Detection range of PIR shown in the following picture


Working Conditions
If there is someone moving within the detection area, then alarm would be triggered, and LED lights would flash in the inductive area at the same time. 
Work schematic diagram of PIR is shown in the following picture

Product Usage

Battery Usage Tips

Battery life of motion sensor is approximately 1 year. The power level of battery would be displayed in the gateway. Red icon means the battery needs replacing, and then mobile app would receive a message “power level is low, please remember to replace battery” from gateway. In order to avoid false alarm, before replacing battery, please disconnect association of motion sensor with other devices. 

Note: PIR motion sensor is powered by battery, and please use battery in a correct way to avoid exploding. When handling the battery, refer to environmental law please.

LED Indicator

- Blink 5 Times (1s Interval): Motion Sensor(PIR) is powered on, and has not added to Z-Wave network yet
- Blink 5 Times (500ms Interval) Enter includsion mode, excluison mode or send Node Info
- Blink 5 Times (300msInterval) Motion Sensor(PIR) has already added to Z-Wave network, and make it powered on again
- Blink 1 Time first, then 5 times on and off alternately. Press and hold the reset button for 10 - 15 seconds to restore PIR sensor to factory settings
- Blink 1 Time 1: Detect a Movement
                     2:Press the Button shortly to Send Wake up information to gateway
 

Reset to factory default
1. Remove the cover of PIR sensor.
2. Make sure the sensor is powered.
3. Press and hold the reset button for 10-15 seconds, then LED lights would flash red color 1 time first, then 5 times on and off alternately.
4. Release the code button.
Inclusion Press the code button in PIR sensor three times continuously
Exclusion Press the code button in PIR sensor three times continuously
NIF XXXNIF
Wakeup
You can press the button once to wake up the sensor and send wakeup notification to gateway. If press successfully, LED light will blink one time.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 4 Lifeline
2 4
Send control commands to associated devices such as relay module, lighting, etc.
3 4
Send Notification to associated devices in this group.
4 4
Sending Sensor Binary Report to associated devices in this group.

Configuration Parameters

Parameter 1: Sensitivity Level Setting

This parameter defines the sensitivity of PIR sensor. At the first time of test, it is recommended to test the sensor with movements from a farthest end of the coverage area . If movements cannot be detected sensitively, simply adjust the sensitivity level by changing this parameter.
Size: 1 Byte, Default Value: 12

Setting Description
8 - 255 Sensitivity Level Setting.

Parameter 2: On/Off Duration

This parameter can determine how long the associated devices should stay ON status. For instance, this parameter is set to 30(second), PIR sensor will send a BASIC SET Command to an associated device with value basic set level if PIR sensor is triggered, and the associated devices will be turned on, and stay in this status for 30(second) before it is turned off automatically.
Size: 2 Byte, Default Value: 30

Setting Description
5 - 600 On/Off Duration Setting

Parameter 3: Basic Set Level

Basic Set Command will be sent where contains a value when motion sensor is triggered, Z-Wave gateway will take it for consideration; for instance, if a lamp module is received the Basic Set Command of which value is decisive as to how bright of dim level of lamp module shall be.
Size: 1 Byte, Default Value: 99

Setting Description
0 OFF
1 - 99 Alarm cancelling or turning a device off
255 ON

Parameter 4: PIR Detecting Function Enabled/Disabled

This parameter can enable or disable PIR detector detecting function.
Size: 1 Byte, Default Value: 255

Setting Description
0 Disable PIR Detector
255 Enable PIR Detector

Parameter 5: Ambient illumination Lux Level

This parameter can be set a lux level value which determines when light sensor is activated. If the ambient illumination level falls below this value, and a person moves across or stands within the detected area , PIR detector will send a Z-Wave ON command(i.e. BASIC_SET value = parameter 3#) to an associated device and activate it.
Size: 2 Byte, Default Value: 100

Setting Description
0 - 1000 LUX

Parameter 6: Re-trigger Interval Setting

This Parameter can be used to adjust the interval of being retriggered after PIR sensor has been triggered. This Parameter value must be less than Parameter 2#.If user set this parameter to default by Configure CC, the parameter #2 will be set to default value
Size: 1 Byte, Default Value: 8

Setting Description
1 - 8 Re-trigger Interval Setting.

Parameter 7: Light Sensor Polling Interval

This Parameter can be set as interval time for light sensor measuring ambient illumination level.
Size: 2 Byte, Default Value: 180

Setting Description
60 - 36000 Light Sensor Polling Interval

Parameter 8: Lux Level Function Enable

If this parameter is set to ‘1’, and when Lux level is less than the value defined by parameter #5, PIR sensor will send a BASIC_SET command frame(i.e. BASIC_SET (value = parameter 3) to an associated device and activate it. If Lux Level is greater than the value defined by parameter #5, PIR sensor will not send a BASIC_SET command frame.


Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable

Parameter 9: Ambient illumination Lux Level Report

This parameter defines how much Lux must be changed first, then PIR sensor will report to z wave gateway.
Size: 1 Byte, Default Value: 100

Setting Description
0 - 255 Lux Level Report

Parameter 10: Led Blink Enable

This parameter defines the Led on/off enable. If this parameter is set to ‘1’, led blink will be enabled, the led will blink once when motion sensor detect a movement. Otherwise, the led will be turned off always.
Size: 1 Byte, Default Value: 1

Setting Description
0 Disable
1 Enable

Parameter 99: Ambient light intensity calibration

This parameter defines the calibrated scale for ambient light intensity. Because the method and position that the sensor is mounted , and the cover of sensor will bring measurement error,user can get more real light intensity by this parameter setting. User should run the steps as blows for calibrating.
Size: 2 Byte, Default Value: 10

Setting Description
1 - 65536 Ambient light intensity calibration

Technical Data

Dimensions 45 x 45 x 48 mm
Weight 25 gr
Hardware Platform ZM5202
EAN 6924715900544
IP Class IP 20
Battery Type 1 * CR123A
Device Type Motion Sensor
Network Operation Sleeping device
Firmware Version 03.61
Z-Wave Version 04.05
Z-Wave Product Id 0x0258.0x0003.0x1083
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeMotion Sensor