This is a
n/a
Smart Garage Door Controller, Z-Wave EnabledNGD00ZSmart Garage Door ControllerAutomation for your GarageWirelessly control and monitor your garage door from anywhere with the safest, most secure Z-Wave NuTone Smart Garage Door Controller -- Patent PendingAssured safe operation with audible and visual notification prior to Open/Close of the garage doorOnly Smart Garage Door Controller with secure barrier command class encryption eliminating unauthorized access to your homeWorks with virtually all sectional automatic garage door openers manufactured after 1993Installs in less than 30 minutesWorks with other Z-Wave devices in your home to ensure full coverage, reducing and eliminating dead spots in even the largest homes.Requires Z-Wave compatible gateway (sold separately)Signal (frequency): 908.42MZUp to 100 feet between wireless gateway and/or the closest Z-Wave deviceNetwork wide inclusion for easy setup
Reset to factory default | Press the "Link" button on the side of the NGD00Z five times within 30 seconds.Please use this procedure only in the event that the network primary controller is missing or otherwise inoperable. |
Inclusion | n/a |
Exclusion | n/a |
NIF | XXXNIF |
Wakeup | n/a |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
As long as this device is not included into a Z-Wave network of a different controller it is able to manage its own Z-Wave network as primary controller. As a primary controller the device can include and exclude other devices in its own network, manage associations, and reorganize the network in case of problems. The following controller functions are supported:
Communication between two Z-Wave devices only works if both belong to the same wireless network. Joining a network is called inclusion and is initiated by a controller. The controller needs to be turned into the inclusion mode. Once in this inclusion mode the other device needs to confirm the inclusion - typically by pressing a button.
If current primary controller in your network is in special SIS mode this and any other secondary controller can also include and exclude devices.
To become primary a contoller have to be resetted and then include a device.
Momentarily press the "Link" button on the side of the NGD00Z to enter Inclusion.The device will stay in Inclusion for 10 to 14 seconds.
The primary controller can exclude devices from the Z-Wave network. During exclusion the relationship between the device and the network of this controller is terminated. No communication between the device and other devices still in the network can happen after a successful exclusion. The controller needs to be turned into the exclusion mode. Once in this exclusion mode the other device needs to confirm the exclusion - typically by pressing a button.
Attention: Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from it's previous network.
Momentarily press the "Link" button on the side of the NGD00Z to enter Exclusion.The device will stay in Exclusion for 10 to 14 seconds.
Hardware Platform | ZM5202 |
Device Type | Secure Door |
Network Operation | Always On Slave |
Firmware Version | 02 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-15040010 |
Z-Wave Product Id | 0x014F.0x4744.0x3530 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |