This is a
The NodOn Smart Plug can be controlled by any kind of Z-Wave® (or Z-Wave Plus®) gateway or other Z-Wave® controller (standalone mode) such as the NodOn® Soft Remote or Octan Remote.
In both standard, Type E (French) or Schuko (German), the plug can be mounted in both side (head up or head down). Combined to its ultra-thin design, these both specificities allow an easy integration, without obstructing nearby power holes on a power strip.
Equipped with a very small super-capacitor, the NodOn Smart Plug is able to send an emergency frame to the gateway in case of power outage.
The NodOn Smart Plug is based on brand new 500 series Z-Wave® module from Sigma Designs®, and support all the new features of Z-Wave Plus® standard:
Longer range (up to 40m), lower power consumption, higher data rate transmission, and many more new features.
Reset to factory default | Long press during more than 5 seconds then release. Please use this procedure only when the primary controller is missing or otherwise inoperable. |
Inclusion | Long press during 2 seconds to send several NIF during 30 seconds or a triple press to send a single NIF |
Exclusion | Long press during 2 seconds to send several NIF during 30 seconds or a triple press to send a single NIF |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plusu00ae Lifeline This group is generally used to report information of the Smart Plug to the Main Controller of the network. |
2 | 5 | Follow State When the Smart Plug is switched ON (respectively OFF) - either locally or by wireless - it will send ON (respectively OFF) command to the associated devices in the group. |
3 | 5 | Follow Complementary State When the Smart Plug is switched ON (respectively OFF) - either locally or by wireless - it will send OFF (respectively ON) command to the associated devices in the group. |
4 | 5 | Power Failure Notification When the Smart Plug detects a power outage or a recover of power, it sends to following command to associated devices in the group. Detected = Power Management - AC disconnected Recovered = Power Management - AC re-connected |
5 | 5 | Power Failure Set ON When the Smart Plug detects a power outage, it sets ON the associated devices in the group. |
6 | 5 | Power Failure Set OFF When the Smart Plug detects a power outage, it sets OFF the associated devices in the group. |
7 | 5 | Power Recover Set ON When the Smart Plug detects a Power Recover, it will switched ON the associated devices in the group. |
8 | 5 | Power Recover Set OFF When the Smart Plug detects a Power Recover, it will switched OFF the associated devices in the group. |
This parameter defines the status of the Smart Plug after a Power Failure or after being plugged. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | ON |
1 | OFF |
2 | Status before power outage |
This parameter is to set the Alarm 3 Specifications. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 2097151999 | To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm |
This parameter is to set the Alarm 4 Type Configuration. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. (Notification type, Event type, Priority, Lock device, Group 2 Enable, Group 3 Enable, Alarm Action, LED behavior, Alarm duration) Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 65535 | To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm |
This parameter is to set the Alarm 4 Specifications. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 2097151999 | To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm |
This parameter is to set the Alarm 5 Type Configuration. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. (Notification type, Event type, Priority, Lock device, Group 2 Enable, Group 3 Enable, Alarm Action, LED behavior, Alarm duration) Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 65535 | To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm |
This parameter is to set the Alarm 5 Specifications. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 2097151999 | To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm |
This parameter is to set the Alarm 6 Type Configuration. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. (Notification type, Event type, Priority, Lock device, Group 2 Enable, Group 3 Enable, Alarm Action, LED behavior, Alarm duration) Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 65535 | To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm |
This parameter is to set the Alarm 6 Specifications. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 2097151999 | To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm |
This parameter is to set the Alarm 7 Type Configuration. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. (Notification type, Event type, Priority, Lock device, Group 2 Enable, Group 3 Enable, Alarm Action, LED behavior, Alarm duration) Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 65535 | To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm |
This parameter is to set the Alarm 7 Specifications. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 2097151999 | To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm |
This parameter is to set the Alarm 8 Type Configuration. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. (Notification type, Event type, Priority, Lock device, Group 2 Enable, Group 3 Enable, Alarm Action, LED behavior, Alarm duration) Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 65535 | To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm |
This parameter is to set-up the Power Failure / Recover notification and the associated group (Groups 4, 5, 6, 7, 8). The value may be the sum of available values. For example, if you want to activate Power Failure and enable group 4 & 5, the parameter value is 1+2+4=7. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Power Failure detection disable |
1 | Power Failure enable (report to Lifeline only) |
2 | Enable group 4 |
4 | Enable group 5 |
8 | Enable group 6 |
16 | Enable group 7 |
32 | Enable group 8 |
This parameter is to set the Alarm 8 Specifications. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 2097151999 | To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm |
This parameter allows to enable or deactivate Group 2 & Group 3. The value may be the sum of available values. For example, if you want to enable Group 2 & 3, the parameter value is 1+2=3. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 | Group 2 and Group3 Disable |
1 | Group 2 Enable |
2 | Group 3 Enable |
This parameter forces the Smart Plug status to be ON. While enable it is not possible to switch OFF the plug (local or wireless). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Always ON disable |
1 | Always ON enable |
This parameter is to set the Alarm 1 Type Configuration. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. (Notification type, Event type, Priority, Lock device, Group 2 Enable, Group 3 Enable, Alarm Action, LED behavior, Alarm duration) Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 65535 | To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm |
This parameter is to set the Alarm 1 Specifications. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 2097151999 | To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm |
This parameter is to set the Alarm 2 Type Configuration. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. (Notification type, Event type, Priority, Lock device, Group 2 Enable, Group 3 Enable, Alarm Action, LED behavior, Alarm duration) Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 65535 | To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm |
This parameter is to set the Alarm 2 Specifications. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 2097151999 | To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm |
This parameter is to set the Alarm 3 Type Configuration. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. (Notification type, Event type, Priority, Lock device, Group 2 Enable, Group 3 Enable, Alarm Action, LED behavior, Alarm duration) Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 65535 | To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm |
Dimensions | 51x36x104 mm |
Weight | 137 gr |
Hardware Platform | ZM5202 |
EAN | 3700313920190 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Z-Wave Version | 6.51.02 |
Certification ID | ZC10-15030002 |
Z-Wave Product Id | 0x0165.0x0001.0x0001 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |