Quickstart

This is a On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. Long press during 2 seconds to send several NIF during 30 seconds or a triple press to send a single NIF



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The NodOn Smart Plug can be controlled by any kind of Z-Wave® (or Z-Wave Plus®) gateway or other Z-Wave® controller (standalone mode) such as the NodOn® Soft Remote or Octan Remote.
In both standard, Type E (French) or Schuko (German), the plug can be mounted in both side (head up or head down). Combined to its ultra-thin design, these both specificities allow an easy integration, without obstructing nearby power holes on a power strip.
Equipped with a very small super-capacitor, the NodOn Smart Plug is able to send an emergency frame to the gateway in case of power outage.

The NodOn Smart Plug is based on brand new 500 series Z-Wave® module from Sigma Designs®, and support all the new features of Z-Wave Plus® standard:
Longer range (up to 40m), lower power consumption, higher data rate transmission, and many more new features.

Reset to factory default Long press during more than 5 seconds then release. Please use this procedure only when the primary controller is missing or otherwise inoperable.
Inclusion Long press during 2 seconds to send several NIF during 30 seconds or a triple press to send a single NIF
Exclusion Long press during 2 seconds to send several NIF during 30 seconds or a triple press to send a single NIF
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plusu00ae Lifeline This group is generally used to report information of the Smart Plug to the Main Controller of the network.
2 5 Follow State When the Smart Plug is switched ON (respectively OFF) - either locally or by wireless - it will send ON (respectively OFF) command to the associated devices in the group.
3 5 Follow Complementary State When the Smart Plug is switched ON (respectively OFF) - either locally or by wireless - it will send OFF (respectively ON) command to the associated devices in the group.
4 5 Power Failure Notification When the Smart Plug detects a power outage or a recover of power, it sends to following command to associated devices in the group. Detected = Power Management - AC disconnected Recovered = Power Management - AC re-connected
5 5 Power Failure Set ON When the Smart Plug detects a power outage, it sets ON the associated devices in the group.
6 5 Power Failure Set OFF When the Smart Plug detects a power outage, it sets OFF the associated devices in the group.
7 5 Power Recover Set ON When the Smart Plug detects a Power Recover, it will switched ON the associated devices in the group.
8 5 Power Recover Set OFF When the Smart Plug detects a Power Recover, it will switched OFF the associated devices in the group.

Configuration Parameters

Parameter 1: DEFAULT STATE

This parameter defines the status of the Smart Plug after a Power Failure or after being plugged.
Size: 1 Byte, Default Value: 2

Setting Description
0 ON
1 OFF
2 Status before power outage

Parameter 10: Alarm 3 Specifications

This parameter is to set the Alarm 3 Specifications. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need.
Size: 4 Byte, Default Value: 0

Setting Description
0 - 2097151999 To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm

Parameter 11: Alarm 4 Type Configuration

This parameter is to set the Alarm 4 Type Configuration. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. (Notification type, Event type, Priority, Lock device, Group 2 Enable, Group 3 Enable, Alarm Action, LED behavior, Alarm duration)
Size: 2 Byte, Default Value: 0

Setting Description
0 - 65535 To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm

Parameter 12: Alarm 4 Specifications

This parameter is to set the Alarm 4 Specifications. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need.
Size: 4 Byte, Default Value: 0

Setting Description
0 - 2097151999 To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm

Parameter 13: Alarm 5 Type Configuration

This parameter is to set the Alarm 5 Type Configuration. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. (Notification type, Event type, Priority, Lock device, Group 2 Enable, Group 3 Enable, Alarm Action, LED behavior, Alarm duration)
Size: 2 Byte, Default Value: 0

Setting Description
0 - 65535 To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm

Parameter 14: Alarm 5 Specifications

This parameter is to set the Alarm 5 Specifications. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need.
Size: 4 Byte, Default Value: 0

Setting Description
0 - 2097151999 To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm

Parameter 15: Alarm 6 Type Configuration

This parameter is to set the Alarm 6 Type Configuration. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. (Notification type, Event type, Priority, Lock device, Group 2 Enable, Group 3 Enable, Alarm Action, LED behavior, Alarm duration)
Size: 2 Byte, Default Value: 0

Setting Description
0 - 65535 To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm

Parameter 16: Alarm 6 Specifications

This parameter is to set the Alarm 6 Specifications. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need.
Size: 4 Byte, Default Value: 0

Setting Description
0 - 2097151999 To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm

Parameter 17: Alarm 7 Type Configuration

This parameter is to set the Alarm 7 Type Configuration. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. (Notification type, Event type, Priority, Lock device, Group 2 Enable, Group 3 Enable, Alarm Action, LED behavior, Alarm duration)
Size: 2 Byte, Default Value: 0

Setting Description
0 - 65535 To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm

Parameter 18: Alarm 7 Specifications

This parameter is to set the Alarm 7 Specifications. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need.
Size: 4 Byte, Default Value: 0

Setting Description
0 - 2097151999 To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm

Parameter 19: Alarm 8 Type Configuration

This parameter is to set the Alarm 8 Type Configuration. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. (Notification type, Event type, Priority, Lock device, Group 2 Enable, Group 3 Enable, Alarm Action, LED behavior, Alarm duration)
Size: 2 Byte, Default Value: 0

Setting Description
0 - 65535 To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm

Parameter 2: POWER FAILURE

This parameter is to set-up the Power Failure / Recover notification and the associated group (Groups 4, 5, 6, 7, 8). The value may be the sum of available values. For example, if you want to activate Power Failure and enable group 4 & 5, the parameter value is 1+2+4=7.
Size: 1 Byte, Default Value: 0

Setting Description
0 Power Failure detection disable
1 Power Failure enable (report to Lifeline only)
2 Enable group 4
4 Enable group 5
8 Enable group 6
16 Enable group 7
32 Enable group 8

Parameter 20: Alarm 8 Specifications

This parameter is to set the Alarm 8 Specifications. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need.
Size: 4 Byte, Default Value: 0

Setting Description
0 - 2097151999 To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm

Parameter 3: FOLLOW STATE

This parameter allows to enable or deactivate Group 2 & Group 3. The value may be the sum of available values. For example, if you want to enable Group 2 & 3, the parameter value is 1+2=3.
Size: 1 Byte, Default Value: 3

Setting Description
0 Group 2 and Group3 Disable
1 Group 2 Enable
2 Group 3 Enable

Parameter 4: ALWAYS ON

This parameter forces the Smart Plug status to be ON. While enable it is not possible to switch OFF the plug (local or wireless).
Size: 1 Byte, Default Value: 0

Setting Description
0 Always ON disable
1 Always ON enable

Parameter 5: Alarm 1 Type Configuration

This parameter is to set the Alarm 1 Type Configuration. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. (Notification type, Event type, Priority, Lock device, Group 2 Enable, Group 3 Enable, Alarm Action, LED behavior, Alarm duration)
Size: 2 Byte, Default Value: 0

Setting Description
0 - 65535 To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm

Parameter 6: Alarm 1 Specifications

This parameter is to set the Alarm 1 Specifications. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need.
Size: 4 Byte, Default Value: 0

Setting Description
0 - 2097151999 To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm

Parameter 7: Alarm 2 Type Configuration

This parameter is to set the Alarm 2 Type Configuration. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. (Notification type, Event type, Priority, Lock device, Group 2 Enable, Group 3 Enable, Alarm Action, LED behavior, Alarm duration)
Size: 2 Byte, Default Value: 0

Setting Description
0 - 65535 To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm

Parameter 8: Alarm 2 Specifications

This parameter is to set the Alarm 2 Specifications. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need.
Size: 4 Byte, Default Value: 0

Setting Description
0 - 2097151999 To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm

Parameter 9: Alarm 3 Type Configuration

This parameter is to set the Alarm 3 Type Configuration. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your need. (Notification type, Event type, Priority, Lock device, Group 2 Enable, Group 3 Enable, Alarm Action, LED behavior, Alarm duration)
Size: 2 Byte, Default Value: 0

Setting Description
0 - 65535 To set-up your values please follow this link : www.nodon.fr/support/asp3/alarm

Technical Data

Dimensions 51x36x104 mm
Weight 137 gr
Hardware Platform ZM5202
EAN 3700313920190
Device Type On/Off Power Switch
Network Operation Always On Slave
Z-Wave Version 6.51.02
Certification ID ZC10-15030002
Z-Wave Product Id 0x0165.0x0001.0x0001
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeOn/Off Power Switch