Quickstart

This is a Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
a.Press & hold Inclusion/Exclusion button for 5 seconds when Open Sensor is exclusion status.b.LED of Open sensor will be on 5 seconds later.c.Open sensor will try Inclusion for 30sec when button is released.d.LED will blink 3 times if Inclusion is successful.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Remote Access via smart phone APPDetecting the status of Door/Windows equipped with Z-WAVE Open Sensor and notifying the status to a customer.Checking the battery usage and reporting the low battery alarm.

Reset to factory default a.Press & hold Inclusion/Exclusion button for 10sec.b.LED will blink while holding the button.c.Factory reset will be done in 5sec after releasing button and LED will blink 5 times.Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Inclusion a.Press & hold Inclusion/Exclusion button for 5 seconds when Open Sensor is exclusion status.b.LED of Open sensor will be on 5 seconds later.c.Open sensor will try Inclusion for 30sec when button is released.d.LED will blink 3 times if Inclusion is successful.
Exclusion a.Receiver will stay exclusion waiting mode.b.Press & hold Inclusion/Exclusion button for 5 seconds when Open Sensor is Inclusion status.c.LED of Open sensor will be on 5 seconds later.d.Open sensor will try Exclusion when button is released.e.LED will blink 3 times if Exclusion is successful.
NIF XXXNIF
Wakeup a.Device sends Wake up Notification by every 15 minutes.b.Devices also sends Wake up Notification when inclusion/exclusionbutton is shortly pressed regardless of 15minutes interval.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 1: Battery Period

Battery Report Period Value.The battery report period is in 15 minute increments.For example, the default value of 24 * 15 minutes = 360 minutes or 6 hours.
Size: 1 Byte, Default Value: 24

Setting Description
1 - 255 Default 24 (0x18), 0x01~0xFF in 15 minute increments

Technical Data

Hardware Platform ZM5101
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 1 FW: 39.20
Z-Wave Version 6.61.00
Certification ID ZC10-17065639
Z-Wave Product Id 0x022c.0x0003.0x0001
Neutral Wire Required ok
Supported Notification Types Access Control
Color White
Firmware Updatable Updatable by Professional/Technician
Sensors Open/Closed (Binary)
Outdoor Use ok
Frequency XXfrequency
Maximum transmission power XXantenna
South KoreaNotification Sensor