Quickstart

This is a On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1.Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. 2.Pressing Include button of PAN05 three times within 2 seconds will enter inclusion mode.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

This in-wall switch module is a transceiver which is a security enabled device which based on Z-Wave Plus technology, and it is fully compatible with any Z-Wave enabled network. Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration. Since PAN05 supports Security Command Class, it can learn with Secured controller. Its functionality and supported command classes is identical when included as a secure and non-secure device. There are many kind of application by using the module to switch Load On and Off, one main application is the light control. If connect the COM terminal directly to AC Lineterminal,thenewsmartrelaycalibrationtechnologycanreducetheinrush current caused by the load and let the module work perfectly with many kind of light likeincandescent,fluorescentandLEDlight.Thismodulecanalsoconnectto alternativepowersupplylikeDC12Vtoswitchon/off12VMR-16light.

Reset to factory default This procedure should only be used in the event that the primary controller is lost or otherwise inoperable.1.Pressing Include button of PAN05 three times within 2 seconds will enter inclusion mode. 2.Within 1 second, press Include button of PAN05 again for 5 seconds. 3.IDs are excluded.
Inclusion 1.Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. 2.Pressing Include button of PAN05 three times within 2 seconds will enter inclusion mode.
Exclusion 1.Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. 2.Pressing Include button of PAN05 three times within 2 seconds will enter inclusion mode.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 The Switch can be set to send reports to associated Z-Wave devices. It supports only one association group and the group has one node support. Group1 support SWITCH_BINARY_REPORT. For group 1, the Switch will report ON/OFF status of Relay to controller.

Configuration Parameters

Parameter 1: Edge orPulsemode orEdge-Toggle mode

Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle mode, default value is Edge mode.
Size: 1 Byte, Default Value: 1

Setting Description
1 Edge mode: this mode is suitable for the bi stable wall switch that has indicator point on the switch, and the same position correspond to same state of relay1.If the PAN05 relay change the state because of receiving Z-Wave RF command, it may need two times of change (switch on to off or switch off to on) to let relay back to the correspond state. Manual switch S2 is disabled in this mode.
2 Pulse mode: this mode is suitable for the toggle type wall switch to swap the state of Relay1.
3 Edge-Toggle mode: this mode is suitable for the normal bi-stable switch, every time when change the state of the wall switch will also swap the state of Relay1.

Parameter 2: Restore switch state mode

Whenever the AC power reconnected to PAN05, it will set the switch to OffOn or Last switch state, default value is Last switch state.
Size: 1 Byte, Default Value: 1

Setting Description
0 Switch off
1 Last switch state
2 Switch on

Parameter 3: ManualOn/Offmode

The On/Off function of S1S2 and learn switch can be disabled or enabled by this parameter, default value is Enable.But the learning operation wont be affected.
Size: 1 Byte, Default Value: 1

Setting Description
0 Disablemanual On/Off
1 Enablemanual On/Off

Parameter 4: LED indication mode

This parameter controls the operation of the LED based upon the current state of the switch.
Size: 1 Byte, Default Value: 1

Setting Description
1 Show switch stateLED on for switch on and off for switch off. The default value is Show switch state.
2 Show night modeLED off for switch on and on for switch off.
3 One Flash modeWhen the state of switch changes, LED will be on only one second, then LED keeps off.

Parameter 5: Auto off timer

This parameter controls the automatic shut-off timer.A value of 0 disables the automatic shut-off feature, a value from 1 to 32767 will represent the number of seconds to elapse until the switch will automatically turn off.
Size: 2 Byte, Default Value: 0

Setting Description
0 Disable auto off function
1 - 32767 Set the auto off function to 1 ~32767 seconds

Parameter 6: RF Offcommandmode

This parameter configures how the switch responds to an RF received Off command using BASIC_SET, BINARY_SWITCH_SET, or SWITCH_ALL_OFF.The default value (0) is to turn off the switch.
Size: 1 Byte, Default Value: 0

Setting Description
1 Ignore
2 Switch toggle
3 Switch on
0 Switch off

Technical Data

Hardware Platform SD3502
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version 01
Z-Wave Version 6.51.00
Certification ID ZC10-14110005
Z-Wave Product Id 0x013C.0x0001.0x0010
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)On/Off Power Switch