Quickstart

This is a Window Covering - Pos/End Aware for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1.Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. 2.Pressing Include button three times within 2 seconds will enter inclusion mode.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The in-wall Roller Shutter Controller is designed to switch rise/lower roller shutter connected to its terminals using radio waves, controllers and a push button directly connected to this Roller Controller. This in-wall Roller Shutter Controller is a transceiver which is a Z-Wave Plus enabled device and is fully compatible with any Z-Wave enabled network. Slim design let the Controller can easily hide itself into the wall box and that will be good for the house decoration. The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of Roller Shutter. This in-wall Roller Shutter Controller is able to detect position of the Shutter by using the patterned power measuring method, so it can be remote controlled not only fully up or down, but also can be adjusted to ex. 30% or 50%.Andwhenmanual controlled by push button, the controller also can memorize the position and send the new shutter position to its controller (ex. IP-Gateway).

Reset to factory default Use this procedure only in the event that the primary controller is lost or otherwise inoperable. 1. Pressing Include button three times within 2 seconds will enter inclusion mode.2.Within 1 second, press Include button again for 5 seconds.
Inclusion 1.Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. 2.Pressing Include button three times within 2 seconds will enter inclusion mode.
Exclusion 1.Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. 2.Pressing Include button three times within 2 seconds will enter exclusion mode.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 1: Watt Meter Report Period

If the setting is configured for 1hour (set value =720), the PAN08 will report its instant power consumption every 1 hour to the node of Group 1. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). Default value is 1 hour.
Size: 2 Byte, Default Value: 720

Setting Description
1 - 32767 5*720s=3600s=1 hour

Parameter 2: KWH Meter Report Period

Ifthesettingisconfiguredfor1hour(setvalue=6),thePAN08willreportits AccumulatedPower Consumption (KW/h) every1 hour to thenode of correspond Group. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). Default value=1 hour.
Size: 2 Byte, Default Value: 6

Setting Description
1 - 32767 6*10min= 1 hour

Parameter 3: Threshold of current for load caution

This is a warning when the current of load over the preset threshold value, if the setting value is 500, when the load current of Relay1 over this value, PAN08 will send current meter report to warn the Group1 node, the Range of the setting value is from 10 to 500, and the default value is 500.
Size: 2 Byte, Default Value: 500

Setting Description
10 - 500 500*0.01A=5A

Parameter 4: Threshold of KWh for Load Caution

This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 or Relay2 over this value, PAN08 will send KWh Meter Report command to the node of correspond Group, minimum value is 1KWh and default value is 10000 kWh.
Size: 2 Byte, Default Value: 10000

Setting Description

Parameter 5: External switch type

There are 2 type switch can be selected.
Size: 1 Byte, Default Value: 2

Setting Description
1 One Push Button When the configuration setting is One Push Button, only S1 input will be valid. The control moving commands can be accepted in this switch type while the shutter is moving. In this switch type, the inclusion/exclusion/reset/association function can also be fulfilled by pressing S1 just like the operation of include button. When S1 is short pressed, the shutter will move up toward TOP(0xFF). While in this moving S1 is short pressed again, the shutter will stop moving. A third short pressing of S1 will move the shutter down toward BOTTOM(0x00). While in this moving S1 is short pressed again, the shutter will stop moving. And so on Inverting direction and stopping.
2 Two Push Button(The default setting is Two Push Button (2)) If this setting is configured as Two Push Button, S1 and S2 input will be valid, but will not accept pressing S1and S2 at the same time. In this switch type, the inclusion/exclusion/reset/association function can also be fulfilled by pressing S1 or S2 just like the operation of include button. When S1 is pressed and hold more than 1.5 seconds, the shutter will move up toward TOP(0xFF), and the shutter will stop moving when S1 is released. When S2 is pressed and hold more than 1.5 seconds, the shutter will move down toward BOTTOM(0x00), and the shutter will stop moving when S2 is released. When S1 is short pressed, the shutter will move up toward TOP(0xFF). While in this moving short pressed S1 again, the shutter just keep moving up toward TOP(0xFF). The easy way to stop this moving is short pressing S2. When S2 is short pressed, the shutter will move down toward BOTTON(0x00). While in this moving short pressed S2 again, the shutter just keep moving down toward BOTTON(0x00). The easy way to stop this moving is short pressing S1.

Parameter 6: Level Report mode

There two modes of reporting the level of PAN08 while moving the shutter.
Size: 1 Byte, Default Value: 2

Setting Description
1 Mode 1 : In 5 seconds period after controlled by a moving command, it will report the destination level when received request command. Out of the 5 seconds period, it will report the actual level of the shutter when received request command.
2 Mode 2 : Whenever the shutter move pass a 10 percent level, it will auto report the level to Group 1 node.

Technical Data

Hardware Platform SD3502
Device Type Window Covering - Pos/End Aware
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.05
Z-Wave Version 6.51.09
Certification ID ZC10-17095768
Z-Wave Product Id 0x013C.0x0001.0x0015
Switch Type Push Button
Window Covering Control Features Position Aware
Firmware Updatable Updatable by Consumer by RF
Supported Meter Type Electric Energy
Frequency XXfrequency
Maximum transmission power XXantenna
BrazilWindow Covering - Pos/End Aware