Quickstart

This is a On/Off Power Switch for CEPT (Europe). To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1.Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. 2.Pressing On/Off button three times within 2 seconds will enter inclusionmode on the switch.

Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.


Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.

If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

This plug-in ON/OFF switch PAN11 is a security enabled wireless switch, based on Z-WavePlustechnology.Z-WavePlusenableddevicesdisplayingtheZ-Wave Plus logo can also be used with it regardless of the manufacturer, and can also be used in other manufacturers Z-Wave enabled networks. Remote On/Off control of theconnectedloadispossiblewithothermanufacturerswireless controller.Each switch is designed to act as a repeater. Repeaters will re-transmit the RF signal to ensurethatthesignalisreceivedbyitsintendeddestinationbyroutingthesignal around obstacles and radio dead spots. Because PAN11 supports Security Command Class, it can learn with Secured controller. Its functionality and supported command classes is identical when included as a secure and non-secure device.Thisplug-inON/OFFswitchisabletodetectinstancewattage(3000W/CE/CN, 1500W/UL/TW/JP)andoverloadcurrent(14.5A)ofconnectedlightsorappliances. When detecting overload state, the Switch will be disabled and its On/Off button will belockoutofwhichLEDwillflashquickly.However,unplugandre-connectthe switch will reset its overload condition to normal status.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.

(Use this procedure only in the event that the primary controller is lost or otherwise inoperable.)1.Pressing On/Off button three times within 2 seconds will enter inclusion mode on the switch.2.Within 1 second, press On/Off button again for 5 seconds.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

1.Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. 2.Pressing On/Off button three times within 2 seconds will enter inclusionmode on the switch.

Exclusion

1.Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. 2.Pressing On/Off button three times within 2 seconds will enter exclusionmode on the switch.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus Lifeline

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.

Parameter 1: Watt Meter Report Period

Ifthesettingisconfiguredfor1hour(setvalue=720),thePAN11willreportits instant power consumption every 1 hour to Group1 node.The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr).
Size: 2 Byte, Default Value: 720

Setting Description
1 - 32767 720*5s=3600s=1 hour

Parameter 2: KWH Meter Report Period:

Ifthesettingisconfiguredfor1hour(setvalue=6),thePAN11willreportits AccumulatedPowerConsumption(KW/h)every1hourtoGroup1node. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days).
Size: 2 Byte, Default Value: 6

Setting Description
1 - 32767 6*10min=1 hour

Parameter 3: Threshold of current for Load Caution

This is a warning when the current of load over the preset threshold value, if the setting value is 1300, when the load current of Relay1 over this value, PAN11 will send current meter report to warn the Group1 node, the Range of the setting value is from 10 to 1300,and the default value is 1300.
Size: 2 Byte, Default Value: 1300

Setting Description
10 - 1300 1300*0.01A = 13A

Parameter 4: Threshold of KWh for Load Caution

This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 over this value, PAN11 will send KWH meter report to warn the Group1 node, minimum value is 1KWh and default value is 10000 kWh.
Size: 2 Byte, Default Value: 10000

Setting Description
1 - 10000 1KWh ~ 10000KWh

Parameter 5: Restore switch state mode

Whenever the AC power return from lost, PAN11 will restore the switch state which could be SWITCH OFFLAST SWITCH STATESWITCH ON. The default setting is LAST SWITCH STATE.
Size: 1 Byte, Default Value: 1

Setting Description
0 - 2 0 : Switch off 1 : Last switch state 2 : Switch on

Parameter 6: Mode of switch off function

When the mode of switch On/Off is set to 0, any command of switch off will be disabledandtheOn/Offfunctionofincludebuttonwillbedisabled.Thedefault setting is enable mode.
Size: 1 Byte, Default Value: 1

Setting Description
0 - 1 0 : Disable 1 : Enable

Parameter 7: LED indication mode

1. Show Switch StateWhen switch is on, LED is on. When switch is off, LED is off. The default setting is Show Switch State.2. Show Night modeWhen switch is on, LED is off. When switch is off, LED is on.3. One Flash modeWhen the state of switch changes, LED will be on only one second, then LED keeps off.
Size: 1 Byte, Default Value: 1

Setting Description
1 - 3 1 : Show switch state 2 : Show night mode 3 : One flash mode

Parameter 8: Auto off timer

Whenever PAN11 switches to on, the auto off timer begin to count down. After the timer decrease to zero, it will switch to off automatically. However if Auto off timer is set as 0, the auto off function will be disabled. The default setting is 0.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 32767 0 : Disable auto off function 1-0x7FFF : 1s ~ 32767s

Parameter 9: RF off command mode

Wheneveraswitchoffcommand,BASIC_SETBINARY_SWITCH_SET SWITCH_ALL_OFF, is received, it could be interpreted as 4 variety of commands. 1. Switch OffIt switches to OFF state. The default setting is Switch Off. 2. IgnoreThe switch off command will be ignored. 3. Switch ToggleIt switches to the inverse of current state. 4. Switch OnIt switches to ON state.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 3 0 : Switch off 1 : Ignore2 : Switch toggle3 : Switch on

Technical Data

Hardware Platform SD3502
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version 01
Z-Wave Version 6.51.00
Certification ID ZC10-14080016
Z-Wave Product Id 0x013C.0x0001.0x0011
Frequency XXfrequency
Maximum transmission power XXantenna

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall controllers.
  • Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.
  • Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.
  • Inclusion — is the process of adding new Z-Wave devices into a network.
  • Exclusion — is the process of removing Z-Wave devices from the network.
  • Association — is a control relationship between a controlling device and a controlled device.
  • Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.
  • Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.