This is a
1. Have Z-WaveTM Controller entered inclusion mode.2. Pressing the tamper key three times within 1.5 seconds to enter the inclusion mode.3. After add successful, the device will wake to receive the setting command from Z-WaveTM Controller about 20 seconds.
It is the Z-WaveTM plus product, it support the security, OTA... Those newest features of the Z-WaveTM technology. Z-WaveTM is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances
Reset to factory default | Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON.2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once.3. IDs are excluded and all settings will reset to factory default. |
Inclusion | 1. Have Z-WaveTM Controller entered inclusion mode.2. Pressing the tamper key three times within 1.5 seconds to enter the inclusion mode.3. After add successful, the device will wake to receive the setting command from Z-WaveTM Controller about 20 seconds. |
Exclusion | 1. Have Z-WaveTM Controller entered exclusion mode.2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode.Node ID has been excluded. |
NIF | XXXNIF |
Wakeup | After the device adding to the network, it will wake-up once per day in default. When it wake-up it will broadcast the Wake Up Notification message to the network, and wake-up 10 seconds for receive the setting commands.The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours. And the interval step is 30 minutes.Press the tamper key once. The device will wake-up 10 seconds. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 8 | The group 1 is for receiving the report message, like triggered event, temperature, humidity etc. |
2 | 8 | The group 2 is for the light control, the device will send the Basic Set command to this group. |
Setting the BASIC command value.When the flood trigger off(0x00), send the BASIC CC to the group 2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 - 127 | Setting the BASIC command value. When the flood trigger off(0x00), send the BASIC CC to the group 2. |
The interval time for auto report thebattery level.0 means turn off auto report.The default value is 12. The tick timecan setting by the configuration No.20. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | The interval time for auto report the battery level. 0 means turn off auto report. The default value is 12. The tick time can setting by the configuration No.20. |
The interval time for auto report thetemperature.0 means turn off auto report.The default value is 12. The tick timecan setting by the configuration No.20. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | The interval time for auto report the temperature. 0 means turn off auto report. The default value is 12. The tick time can setting by the configuration No.20. |
The interval time for auto report thehumidity.0 means turn off auto report.The default value is 12. The tick timecan setting by the configuration No.20. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | The interval time for auto report the humidity. 0 means turn off auto report. The default value is 12. The tick time can setting by the configuration No.20. |
The interval time for auto report theflood state.0 means turn off auto report.The default value is 12. The tick timecan setting by the configuration No.20. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | The interval time for auto report the flood state. 0 means turn off auto report. The default value is 12. The tick time can setting by the configuration No.20. |
Setting the BASIC command value.When the flood trigger on(0xFF), send the BASIC CC to the group 2. Size: 1 Byte, Default Value: -127
Setting | Description |
---|---|
-128 - 127 | Setting the BASIC command value. When the flood trigger on(0xFF), send the BASIC CC to the group 2. |
The interval time for auto report eachtick. Setting this configuration willeffect configuration No.10, No.13,No.14 and No.15.Units of one minute.Caution1: Setting to 0 means turn offall auto report function.Caution2: The value is unsigned byte Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
-128 - 127 | The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.13, No.14 and No.15. Units of one minute. |
The temperature differential to report.0 means turn off this function.The unit is Fahrenheit.Enable this function the device willdetect every 10 seconds.And when the temperature is over 140degree Fahrenheit, it will continuereport. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 127 | The temperature differential to report. 0 means turn off this function. The unit is Fahrenheit. Enable this function the device will detect every 10 seconds. And when the temperature is over 140 degree Fahrenheit, it will continue report. |
The humidity differential to report.0 means turn off this function.The unit is percentage.Enable this function the device willdetect every 10 seconds. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 - 60 | The humidity differential to report. 0 means turn off this function. The unit is percentage. Enable this function the device will detect every 10 seconds. |
Operation mode. Using bit to control.Bit0: Disable the Flood functionBit3: Setting the temperature scale.0: Fahrenheit, 1:CelsiusBit5: Disable the temperature reportafter event triggered. (1:Disable,0:Enable) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Bit0: Disable the Flood function. |
3 | Bit3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius |
5 | Bit5: Disable the temperature report after event triggered.(1:Disable, 0:Enable) |
Multisensor function switch. Using bitto control.Bit6: Disable the humidity report afterevent triggered. (1:Disable, 0:Enable) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
6 | Bit6: Disable the humidity report after event triggered.(1:Disable, 0:Enable) |
Customer function switch, using bitcontrol.Bit3: Disable send out BASIC OFFafter the flood event cleared.(1:Disable, 0:Enable)Bit4: Notification Type,0: Using Notification Report.1: Using Sensor Binary ReportBit5: Disable Multi CC in auto report.(1:Disable, 0:Enable)Bit6: Disable to report battery statewhen the device triggered. (1:Disable,0:Enable) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
3 | Bit3: Disable send out BASIC OFF after the flood event cleared. (1:Disable, 0:Enable) |
4 | Bit4: Notification Type, 0: Using Notification Report.1: Using Sensor Binary Report. |
5 | Bit5: Disable Multi CC in auto report. (1:Disable, 0:Enable) |
6 | Bit6: Disable to report battery state when the device triggered. (1:Disable, 0:Enable) |
Hardware Platform | SD3502 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 1.14:01.12 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-18036035 |
Z-Wave Product Id | 0x013C.0x0002.0x001F |
Supported Notification Types | Home SecurityWater Alarm |
Sensors | Air TemperatureHumidity |
Frequency | Russia - 868.4MHz, 869.85MHz |
Maximum transmission power | 5 mW |