Quickstart

This is a Notification Sensor for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1. Have Z-WaveController entered inclusion mode.2. Pressing the tamper key three times within 1.5 seconds to enter the inclusion mode.3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The flood multisensor PAT02 has flood, based on Z-Wavetechnology. It is theZ-Wave plus product, it support the security, OTA... Those newest features of theZ-Wave technology. Z-Wave is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and lightcommercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances. This product can be included and operated in any Z-Wave network with other Z-Wavecertified devices from other manufacturers and/or other applications.All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.

Reset to factory default Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4 th pressed, and the LED will light ON.2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once.3. IDs are excluded and all settings will reset to factory default.
Inclusion 1. Have Z-WaveController entered inclusion mode.2. Pressing the tamper key three times within 1.5 seconds to enter the inclusion mode.3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds.
Exclusion 1. Have Z-WaveController entered exclusion mode.2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode. Node ID has been excluded.
NIF XXXNIF
Wakeup When the device power on, the device will wake about 20 seconds. Inthis duration, the controller can communicate with the device. Normallythe device is always sleeping to save the battery energy.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 8 The group 1 is for receiving the report message, like triggered event, temperature, humidity etc.And each group support 8 nodes.
2 8 The group 2 is for the light control, the device will send the Basic Set command to this group. And each group support 8 nodes.

Configuration Parameters

Parameter 1: Basic Set OFF Level

Setting the BASIC command value. When the flood trigger off(0x00), send the BASIC CC to the group 2.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 255 Setting the BASIC command value 0x00.

Parameter 10: AutoReportBattery Time

The interval time for auto report the battery level. 0 means turn off auto report.The default value is 12. The tick time can setting by the configuration No.20.
Size: 1 Byte, Default Value: 12

Setting Description
0 - 127 The interval time for auto report thebattery level.

Parameter 15: Auto Report Flood Time

The interval time for auto report the flood state. 0 means turn off auto report.The default value is 12. The tick time can setting by the configuration No.20.
Size: 1 Byte, Default Value: 12

Setting Description
0 - 127 The interval time for auto report the flood state.

Parameter 2: Basic Set ON Level

Setting the BASIC command value.When the flood trigger on(0xFF), send the BASIC CC to the group 2.
Size: 1 Byte, Default Value: 255

Setting Description
0 - 255 Setting the BASIC command value 0xFF.

Parameter 20: Auto Report Tick Interval

The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.13, No.14 and No.15. Units of one minute.Caution1: Setting to 0 means turn off all auto report function.Caution2: The value is unsigned byte
Size: 1 Byte, Default Value: 30

Setting Description
0 - 255 The interval time for auto report each tick.

Parameter 5: Operation Mode

Operation mode. Using bit to control.
Size: 1 Byte, Default Value: 32

Setting Description
1 Disable the Flood function.

Parameter 7: Customer Function

Customer function switch, using bit control.
Size: 1 Byte, Default Value: 0

Setting Description
64 Disable to report battery statewhen the device triggered. (1:Disable,0:Enable)
32 Disable Multi CC in auto report.(1:Disable, 0:Enable)
16 Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report.
8 Disable send out BASIC OFFafter the flood event cleared.(1:Disable, 0:Enable)

Technical Data

Hardware Platform SD3502
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version 01
Z-Wave Version 6.51.06
Certification ID ZC10-15060011
Z-Wave Product Id 0x013C.0x0002.0x0021
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Notification Sensor