This is a
1. Have Z-WaveController entered inclusion mode.2. Pressing the tamper key three times within 1.5 seconds to enter the inclusion mode.3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds.
The flood multisensor PAT02 has flood, based on Z-Wavetechnology. It is theZ-Wave plus product, it support the security, OTA... Those newest features of theZ-Wave technology. Z-Wave is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and lightcommercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances. This product can be included and operated in any Z-Wave network with other Z-Wavecertified devices from other manufacturers and/or other applications.All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
Reset to factory default | Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4 th pressed, and the LED will light ON.2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once.3. IDs are excluded and all settings will reset to factory default. |
Inclusion | 1. Have Z-WaveController entered inclusion mode.2. Pressing the tamper key three times within 1.5 seconds to enter the inclusion mode.3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds. |
Exclusion | 1. Have Z-WaveController entered exclusion mode.2. Pressing tamper key three times within 1.5 seconds to enter the exclusion mode. Node ID has been excluded. |
NIF | XXXNIF |
Wakeup | When the device power on, the device will wake about 20 seconds. Inthis duration, the controller can communicate with the device. Normallythe device is always sleeping to save the battery energy. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 8 | The group 1 is for receiving the report message, like triggered event, temperature, humidity etc.And each group support 8 nodes. |
2 | 8 | The group 2 is for the light control, the device will send the Basic Set command to this group. And each group support 8 nodes. |
Setting the BASIC command value. When the flood trigger off(0x00), send the BASIC CC to the group 2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 255 | Setting the BASIC command value 0x00. |
The interval time for auto report the battery level. 0 means turn off auto report.The default value is 12. The tick time can setting by the configuration No.20. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | The interval time for auto report thebattery level. |
The interval time for auto report the flood state. 0 means turn off auto report.The default value is 12. The tick time can setting by the configuration No.20. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | The interval time for auto report the flood state. |
Setting the BASIC command value.When the flood trigger on(0xFF), send the BASIC CC to the group 2. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 255 | Setting the BASIC command value 0xFF. |
The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.13, No.14 and No.15. Units of one minute.Caution1: Setting to 0 means turn off all auto report function.Caution2: The value is unsigned byte Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
0 - 255 | The interval time for auto report each tick. |
Operation mode. Using bit to control. Size: 1 Byte, Default Value: 32
Setting | Description |
---|---|
1 | Disable the Flood function. |
Customer function switch, using bit control. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
64 | Disable to report battery statewhen the device triggered. (1:Disable,0:Enable) |
32 | Disable Multi CC in auto report.(1:Disable, 0:Enable) |
16 | Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report. |
8 | Disable send out BASIC OFFafter the flood event cleared.(1:Disable, 0:Enable) |
Hardware Platform | SD3502 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | 01 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-15060011 |
Z-Wave Product Id | 0x013C.0x0002.0x0021 |
Frequency | XXfrequency |