Quickstart

This is a secure Light Dimmer Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Place your Z-Wave controller in "Inclusion" mode. Then tap the button once to initiation Inclusion.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

ZLINK PD-100 is a Z-Wave Plus certified device with S2 security and SmartStart features. You can now add this device securely and with ease using QR code on the product with compatible gateways supporting S2 and Smart Start. PD-100 communicates with other Z-Wave certified devices and updates your home into a smart home. PD-100 can be used to turn any plug in lamps into a smart lamp with dimmable light bulbs, turning it On, Off, or control dimming wirelessly. Each Z-Wave device also serves as a node to repeat the signal in the network, thus, extending the overall Z-Wave mesh wireless network range.Additional Features: Power 120 VAC, 60Hz, up to 300 watts Region US: 908.4, 916 MHz Works w/ most incandescent, dimmable CFL & LED lights Plugs into Standard AC outlet Remotely controls On, Off, or Dim levels Control lights via schedule LED backlit manual On/Off button Second wall AC outlet remains free Works with any certified gateway supporting Z-Wave

Reset to factory default 1. Unplug the PD-100 from the AC outlet and also unplug the power plugs of the lighting from the module (if plugged in)2. Press and hold the button on the PD-1003. Plug the PD-100 back into the AC outlet with the button pressedAfter 3 seconds, release the button. If you see the button blink, that means that PD-100 has been reset successfully.Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Inclusion Place your Z-Wave controller in "Inclusion" mode. Then tap the button once to initiation Inclusion.
Exclusion Place your Z-Wave controller in "Exclusion" mode. Then tap the button to initiation Exclusion.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 1. Z-Wave Plus Lifeline2. Device Reset Locally Notification

Configuration Parameters

Parameter 10: Timer

Parameter 10 indicates the time duration of each level. The resolution is 10 milliseconds. For example a default value of 3 means the timer runs out every 30 milliseconds.
Size: 1 Byte, Default Value: 3

Setting Description
1 - 255 Parameter 10 indicates the time duration of each level. The resolution is 10 milliseconds. For example a default value of 3 means the timer runs out every 30 milliseconds.

Parameter 3: Night Light

The LED indicator will be OFF when the connected light is ON and vice versa.When value =0 the LED indicator will be OFF when the the connected light is ON, and the LED will be ON when the connected light is OFF. If value =1 the LED indicator will be ON when the connected light is ON, and the LED indicator will be OFF when the connected light is OFF. If value =2 the LED indicator will always be OFF regardless of the load status
Size: 1 Byte, Default Value: 0

Setting Description
0 - 2 When value =0 the LED indicator will be OFF when the the connected light is ON, and the LED will be ON when the connected light is OFF. If value =1 the LED indicator will be ON when the connected light is ON, and the LED indicator will be OFF when the connected light is OFF. If value =2 the LED indicator will always be OFF regardless of the load status

Parameter 9: Level

Parameter 9 indicates the number of levels when the lighting when the timer runs out.
Size: 1 Byte, Default Value: 1

Setting Description
1 - 99 Parameter 9 indicates the number of levels when the lighting when the timer runs out.

Technical Data

Hardware Platform ZM5202
Device Type Light Dimmer Switch
Network Operation Always On Slave
Firmware Version HW: 255 FW: 50.03
Z-Wave Version 6.81.00
Certification ID ZC10-18025997
Z-Wave Product Id 0x0315.0x4744.0x3032
Outdoor Use ok
Firmware Updatable Updatable by Consumer by RF
Color White
Electric Load Type Dimmable FluorescentDimmable LEDFluorescentIncandescentLED
Switch Type Push Button Illuminated
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoLight Dimmer Switch