Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. There is a button on PSP05.
1. Have Z-Wave Controller entered inclusion mode.
2. Pressing button once to enter the inclusion mode.
3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This device is a Security Enabled Z-Wave Plus Product. Z-WaveTM is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances. This product can be included and operated in any Z-WaveTM network with other Z-WaveTM certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.

Installation

Product Usage

Operation Mode

There are two modes “Test” and “Normal”. “Test Mode” is for the user test the sensor function when installation.“Normal Mode” is for the normal operation. Operation Mode can be switched by pressing tamper key three times. LED can indicate which mode it is. Lighting on one second means entering test mode, flashing once means entering normal mode. When the event triggered, normally the LED won"t indicated, unless the battery is in the low level, the LED will flash once. But in the “Test Mode” the LED also will light ON one second. When the event triggered, the device will report the messages to the nodes in the group 1. The messages also include the battery level. The user can switch the report by setting the configuration NO. 7 bit6 (battery). When the event triggered, the device will emit the signal to turn ON the lighting equipment, those nodes are in the group 2. And delay a while to turn OFF the lighting equipment. The delay time is setting by the configuration NO. 9. The PIR motion re-detected interval, in the “Test Mode” fixed to 6 seconds. In the “Normal Mode”, it according to the setting of the configuration NO. 8. 

Choosing a Suitable Location 

1. The recommended mounting height is 160cm
2. Don"t let the device facing the window or the sunlight.
3. Don"t let the device facing the source of heat. For instance the heater or the air-condition.

Reset to factory default 1. Pressing button for about 5 seconds.
2. IDs are excluded and all settings will reset to factory default.
Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.
Inclusion Pressing button once to enter the inclusion mode.
Exclusion Pressing button once to enter the exclusion mode.
NIF XXXNIF
Wakeup There is a button on PSP05. Press the button once, the device will awake 10 seconds.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 8 Z-Wave Plus Lifeline
2 8 light control

Configuration Parameters

Parameter 2: Basic Set Level

Setting the BASIC command value to turn on the light.
Size: 1 Byte, Default Value: -1

Setting Description
-128 - 127 Basic command value to turn on the light.

Parameter 3: PIR Sensitivity

PIR sensitivity setting.0 means disable the PIR motion. High sensitivity means can detected long distance,but if there is more noise signal in the environment, it will re-trigger too frequency.
Size: 1 Byte, Default Value: 80

Setting Description
0 - 99 PIR sensitivity setting.

Parameter 6: Multi-Sensor Function Switch

Multisensor function switch.
Size: 1 Byte, Default Value: 5

Setting Description
8 When Bit2 is 0(Enable), Are the device and the lighting in the same room? 0:In the same room(Default), 1:In the different room.
16 Disable delay 5 seconds to turn off the light,when door/window closed.(1:Disable, 0:Enable)
32 Disable auto turn off the light,after door/window opened to turn on the light.(1:Disable, 0:Enable)

Parameter 7: Customer Function


Size: 1 Byte, Default Value: 4

Setting Description
2 Enable sending motion OFF report.(0:Disable, 1:Enable)
4 Enable PIR suoer sensitivity mode.
16 Notification Type,0:Using Notification Report. 1: Using Sensor Binary Report.
32 Disable Multi CC in auto report.(1:Disable, 0:Enable)
64 Disable to report battery state when the device triggered.(1:Disable, 0:Enable)

Parameter 8: PIR Re-Detect Interval Time

In the normal mode, after the PIR motion detected, setting the re-detect time.8 seconds per tick,default tick is 3(24 seconds).Setting the suitable value to prevent received the trigger signal too frequently. Also can save the battery energy.
Size: 1 Byte, Default Value: 3

Setting Description
1 - 127 Re-detect time

Parameter 9: Turn Off Light Time

After turn on the light,setting the delay time to turn off the lighting when the PIR motion to turn off the lighting when the PIR motion is not detected.8 seconds per tick,default tick is 4(32 seconds).
Size: 1 Byte, Default Value: 4

Setting Description
0 - 127 Delay time to turn off the lighting when the PIR motion is not detected.

Parameter 10: Auto Report Battery Time

The Interval time for auto report the battery level.0 means turn off auto report battery.The default value is 12.The tick time can setting by the configuration NO.20.
Size: 1 Byte, Default Value: 12

Setting Description
0 - 127 The interval time for auto report the battery level.

Parameter 20: Auto Report Tick Interval

The interval time for auto report each tick.Setting this configuration will effect configuration NO.1
Size: 1 Byte, Default Value: 30

Setting Description
-128 - 127 The interval time for auto report each tick.

Technical Data

Dimensions 0.0480000x0.0830000x0.0680000 mm
Weight 70 gr
Hardware Platform SD3502
EAN 4713698573508
IP Class IP 43
Voltage 3V
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Z-Wave Version 6.51.09
Certification ID ZC10-16105258
Z-Wave Product Id 0x013C.0x0002.0x0050
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeNotification Sensor