Quickstart

This is a secure Wall Controller for XXXQFrequencyName. To run this device please insert fresh 1 * 3,7 V Lithium batteries. To run this device please make sure the internal battery is fully charged. 1. Have Z-Wave Controller entered inclusion mode.
2. Rotate to area A and then press button three times within 1.5 seconds to enter the inclusion mode.
3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This device is a multiple functions button switch. It is able to switch the appliances on/off or adjust the percentage of dimmer.
It can also work as a timer. The well designed wall bracket and magnetic back let the switch can be fixed on the wall. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications.

Product Usage

This device can control dimmers in group 2 using three ways: Dimmer, Timer, and On/Off Switch. Point the arrowhead to area A(shown in Fig. 1 and Fig. 2) then hold the button, release after the red LED go out. One beep means entering Timer mode or two beeps means entering Dimmer mode. The device can switch to On/Off Switch mode automatically when fitting horizontal.


This device is able to set dimmer level by rotating to different angle. When the status is Off, surround LED will not work except in area A(shown in Fig. 1). Rotate the device to area B, C, D(shown in Fig. 1) then touch the button can set the status to On. After a short beep, the surround LED will change gradually from blue to red in area D. It will send Basic set command automatically 1 second after rotating stop. To turn Off the device in group 2, you can rotate PSR04 to area C or touch the button again.

Timer

This mode can time the length of turning Off the light. The length is up to 15 minutes. When counting down starts, surround LED will flash and buzzer will sound according to the remaining time. Rotating to area C can cancel counting down directly.


*On/Off Switch

This device is able to work as On/Off switch by sending Basic set according to configuration NO.1 and NO.2 when fitting horizontal.

Reset to factory default 1. Rotate to area A and then press button four times within 1.5 seconds and do not release the button in the 4 th pressed, and the red LED will light ON.
2. After the red LED goes out, release the button within 2 seconds. 3. IDs are removed and all settings will reset to factory default.
Inclusion Rotate to area A and then press button three times within 1.5 seconds to enter the inclusion mode.
Exclusion Rotate to area A and then press button three times within 1.5 seconds to enter the exclusion mode. Node ID has been removed.
NIF XXXNIF
Wakeup After the device adding to the network, it will wake-up once per day in default. When it wake-up it will broadcast the “Wake Up Notification” message to the network, and wake-up 20 seconds for receive the setting commands. The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours. And the interval step is 30 minutes. If the user wants to wake-up the device immediately, please rotate to area A and then press the button once. The device will wake-up 10 seconds.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 8 Z-Wave Plus Lifeline. The group 1 is for receiving the report message, like triggered event, temperature, humidity etc.
2 8 Lighting control group

Configuration Parameters

Parameter 1: Basic Set OFF level

Control the value representedby the left-side in area D. E.g. Setting this configuration to 16 means range of Command Basic Set value start from 16
Size: 1 Byte, Default Value: 0

Setting Description
0 - 99 Control the value represented by the left-side in area D.

Parameter 2: Basic Set ON level

Control the value representedby the right-side in area D. E.g. Setting this configurationto 30 means range of Command Basic Set value start from 30
Size: 1 Byte, Default Value: 99

Setting Description
0 - 99 Control the value represented by the right-side in area D.

Parameter 10: Auto Report Battery Time

The interval time for auto report the battery level. 0 means turn off auto report battery. The default value is 12. The value is in minutes.Each unit means 30 minutes
Size: 1 Byte, Default Value: 12

Setting Description
0 - 127 The interval time for auto report the battery level.

Parameter 25: Customer Function

Customer defined function Bitset: 1 + 2 = 3
Size: 1 Byte, Default Value: 0

Setting Description
1 Dimmer setting method. 0 : Auto send Command Basic Set after rotating. 1 : Send Command Basic Set by touching key after rotating
2 Disable buzzer in timer mode. 0: Enable. 1: Disable.

Parameter 26: Disable Scene Holding report

Send Central Scene Holding when the button is held.
Size: 1 Byte, Default Value: 0

Setting Description
0 Enable
1 Disable

Technical Data

Dimensions 71x17 mm
Weight 52 gr
Hardware Platform SD3502
EAN 4713698571542
IP Class IP 20
Battery Type 1 * 3,7 V Lithium
Device Type Wall Controller
Network Operation Portable Slave
Firmware Version 01.07
Z-Wave Version 04.05
Certification ID ZC10-15090007
Z-Wave Product Id 0x013c.0x0009.0x0022
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeWall Controller