Quickstart

This is a Binary Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.

Tripple Click the Button on the device confirms the inclusion, exclusion and association. After power up it will stay in auto inclusion mode for 4 minutes. To support handling of the device when already installed the external switch can be used for inclusion or exclusion for 3 minutes after power up.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This Insert Switch allows controlling two independent loads both wirelessly via Z-Wave and locally utilizing a traditional wall switch. Thanks to its calibration technology the device cannot only be used to switch resistive devices but also works perfectly with many kind of reactive or resistive loads such as fluorescent lights or LEDs. This insert switch module has a power meter function and is able to measure instant power, voltage, current, power factor and accumulated power consumption. In addition to this, the device has an overload protection. The device is placed in a wall box right behind the normal switch. The switch is not longer directly connected to the load but acts as input device for the insert that is controlling the load. This device is designed for a 3 wire system and needs a neutral wire in the wall box.

Installation

Put the in wall switch into a wall box and connect the pins as shown in the figure.

Product Usage

Manual Operation

The device can be operated suing the externally connected switch. Three different modes are supported:

  • Edge Mode: Die Position of the external switch determines the switching state of the relay. After a wireless switching command it may be needed to operate the switch twice to return to the direct relation of switch position and relay state. This mode is the factory default mode.
  • Toogle Mode: Each "ON"-Position of the external switch will toggle the state of the relays. This mode is particularly suited for mono-stable switches.
  • Edge/Toggle-Mode: Every change of the state of the external switch results in a change of the relay state.

Remote Operation

Remote On/Off control of the switch is possible with any Z-Wave controller. Further you can set associations to let your device controlled by other Z-Wave devices like sensors.

The switch is able to detect the current wattage (5 - 1500W) and overload wattage (1600 - 1700W) of connected loads. When detecting overload state, the switch will be disabled and the LED will flash quickly. Turning off and on of the power supply will reset from this state.

Reset to factory default

Tripple Click the button on the device to enter inclusion mode. Within 1 second press the button again for 5 seconds until LED is off.

Inclusion

Tripple Click the button on the device confirms inclusion and exclusion. After power up it will stay in auto inclusion mode for 4 minutes. To support handling of the device when already installed the external switch can be used for inclusion or exclusion for 3 minutes after power up.

Exclusion

Tripple Click the button on the device confirms inclusion and exclusion. After power up it will stay in auto inclusion mode for 4 minutes. To support handling of the device when already installed the external switch can be used for inclusion or exclusion for 3 minutes after power up.

NIF

Tripple Click the button on the device sends out a Node Information Frame.

Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1
The Switch will report: (1) ON/OFF status of Relay1 and Relay2; (2) Instant Power Consumption (Watt) of Relay1 and Relay2; (3) Accumulated Power Consumption (KWh) of Relay1 and Relay2 to Z-Wave Controller.
2 1
The Switch will report: (1) ON/OFF status of Relay1; (2) Instant Power Consumption (Watt) of Relay1; (3) Accumulated Power Consumption (KWh) of Relay1 to Z-Wave Controller. 
3 1
The Switch will report: (1) ON/OFF status of Relay2; (2) Instant Power Consumption (Watt) of Relay2; (3) Accumulated Power Consumption (KWh) of Relay2 to Z-Wave Controller.

Configuration Parameters

Parameter 1: Watt Meter Report Period

If the setting is configured for 1hour (set value =720), the PAN04 will report its instant power consumption every 1 hour to the node of correspond Group. The maximum interval to report its instant power consumption is 45 hours.

Size: 2 Byte, Default Value: 720

Setting Description
1 - 32767 720*5s=3600s=1 hour

Parameter 2: KWH Meter Report Period

If the setting is configured for 1hour (set value =6), the PAN04 will report its Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond Group. The maximum interval to report its Accumulated PowerConsumption (KW/h) is 227.55 days.

Size: 6 Byte, Default Value: 2

Setting Description
1 - 32767 6*10min= 1 hour

Parameter 3: Selected Relay

If Controller not using Multi_Channel command class to access the relay of PAN04, you may configure the select value to react the Basic Command Class Binary Switch Command Class or Meter Command Class V3

Size: 1 Byte, Default Value: 3

Setting Description
1 Relay1
2 Relay2
3 Relay1 & Relay2

Parameter 4: Edge or Pulse mode or Edge-Toggle mode

Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle mode.

Size: 1 Byte, Default Value: 1

Setting Description
1 Edge mode
2 Pulse mode
3 Edge-Toggle mode

Parameter 5: Threshold of current for Load Caution

This is a warning when the current of load over the preset threshold value, if the setting value is 750, when the load current of Relay1 or Relay2 over this value, PAN04 will send current meter report to the node of correspond Group.

Size: 2 Byte, Default Value: 750

Setting Description
10 - 750 750*0.01A = 7.5A

Parameter 6: Threshold of KWH for Load Caution

This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 or Relay2 over this value, PAN04 will send KWh Meter Report command to the node of correspond Group.

Size: 2 Byte, Default Value: 10000

Setting Description
1 - 10000 1KWh

Parameter 7: Restore switch state mode

Whenever the AC power return from lost, PAN04 will restore the switch state which could be SWITCH OFF, LAST SWITCH STATE, SWITCH ON

Size: 1 Byte, Default Value: 1

Setting Description
0 OFF
1 Last switch state
2 Switch on

Parameter 8: Auto off timer

Whenever PAN04 switches to on, the auto off timer begin to count down. After the timer decrease to zero, it will switch off automatically.
Size: 2 Byte, Default Value: 0

Setting Description
0 Disable
1 - 32767 Time in seconds

Parameter 9: RF off command mode


Size: 1 Byte, Default Value: 0

Setting Description
0 Switch Off
1 Ignore
2 Switch toggle
3 Switch On

Parameter 10: Existence of Endpoint3

Multi-Channel Command is a good way to control relay1 and relay2 of PAN04 individually. The endpoint3 of PAN04 is related to both relay1 and relay2. In some condition it becomes redundant in Multi-Channel Command Class. When the Existence of Endpoint3 is set as 2, the endpoint3 will be disabled. 

Size: 1 Byte, Default Value: 1

Setting Description
1 Endpoint3 exist
2 No Endpoint3

Technical Data

Dimensions 0.0480000x0.1300000x0.0160000 mm
Weight 40 gr
Hardware Platform ZM3102
Device Type On/Off Power Switch
Generic Device Class Binary Switch
Specific Device Class Binary Power Switch
Firmware Version 01.00
Z-Wave Version 03.41
Certification ID ZC08-13060013
Z-Wave Product Id 013c.0001.0003
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeOn/Off Power Switch