Quickstart

This is a Binary Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.

Tripple Click the Button on the device confirms the inclusion, exclusion and association. After power up it will stay in auto inclusion mode for 4 minutes. To support handling of the device when already installed the external switch can be used for inclusion or exclusion for 3 minutes after power up.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This Insert Switch allows controlling two independent loads both wirelessly via Z-Wave and locally utilizing a traditional wall switch. Thanks to its calibration technology the device cannot only be used to switch resistive devices but also works perfectly with many kind of reactive or resistive loads such as fluorescent lights or LEDs. The device is placed in a wall box right behind the normal switch. The switch is not longer directly connected to the load but acts as input device for the insert that is controlling the load. This device is designed for a 3 wire system and needs a neutral wire in the wall box.

Installation

Put the in wall switch into a wall box and connect the pins as shown in the figure.

Product Usage

Manual Operation

The device can be operated using the externally connected switch. Three different modes are supported:

  • Edge Mode: Die Position of the external switch determines the switching state of the relay. After a wireless switching command it may be needed to operate the switch twice to return to the direct relation of switch position and relay state. This mode is the factory default mode.
  • Toogle Mode: Each "ON"-Position of the external switch will toggle the state of the relays. This mode is particularly suited for mono-stable switches.
  • Edge/Toggle-Mode: Every change of the state of the external switch results in a change of the relay state.

Remote Operation

Remote On/Off control of the switch is possible with any Z-Wave controller. Further you can set associations to let your device controlled by other Z-Wave devices like sensors.

Reset to factory default

Tripple Click the button on the device to enter inclusion mode. Within 1 second press the button again for 5 seconds until LED is off.

Inclusion

Tripple Click the button on the device confirms inclusion. After power up it will stay in auto inclusion mode for 4 minutes. To support handling of the device when already installed the external switch can be used for inclusion or exclusion for 3 minutes after power up.

Exclusion

Tripple Click the button on the device confirms exclusion. 

NIF Tripple Click the button on the device sends out a Node Information Frame.
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 The Switch will report ON/OFF status of Relay1 and Relay2
2 1 The Switch will report ON/OFF status of Relay1
3 1 The Switch will report ON/OFF status of Relay2

Configuration Parameters

Parameter 1: Slected Relay

If Controller not using Multi_Channel command class to access the relay of PAN06, you may configure the select value to react the Basic Command Class or Binary Switch Command Class.
Size: 1 Byte, Default Value: 3

Setting Description
1 Relay 1
2 Relay 2
3 Relay 1 und Relay 2

Parameter 2: Edge or Pulse mode or Edge-Toggle mode

Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle mode.
Size: 1 Byte, Default Value: 1

Setting Description
1 Edge Mode
2 Pulse Mode
3 Edge/Toggle Mode

Parameter 3: Restore switch state mode

Whenever the AC power return from lost, PAN06 will restore the switch state which could be SWITCH OFF、LAST SWITCH STATE、SWITCH ON.
Size: 1 Byte, Default Value: 1

Setting Description
0 Switch off
1 Last switch state
2 Switch on

Parameter 4: Auto off timer

Whenever PAN06 switches to on, the auto off timer begin to count down. After the timer decrease to zero, it will switch to off automatically. However if Auto off timer is set as 0, the auto off function will be disabled.
Size: 2 Byte, Default Value: 0

Setting Description
0 Disable
1 - 32767 Seconds

Parameter 5: RF off command mode

Whenever a switch off command, BASIC_SET, BINARY_SWITCH_SET, SWITCH_ALL_OFF, is received, it could be interpreted as 4 variety of commands.
Size: 1 Byte, Default Value: 0

Setting Description
0 Switch off
1 ignore
2 Switch toggle
3 Switch on

Parameter 6: Existence of Endpoint3

The endpoint3 of Multi-Channel Command Class is related to relay1 and relay2. It may be redundant for the need to control relay1 or relay2 individually. When the Existence of Endpoint3 is set as 0, the endpoint3 of Multi-Channel Command Class will be disabled.
Size: 1 Byte, Default Value: 1

Setting Description
1 Endpoint3 exist
2 No Endpoint3

Technical Data

Dimensions 0.0470000x0.0390000x0.0160000 mm
Weight 40 gr
Hardware Platform SD3502
EAN 4713698571160
IP Class IP 20
Voltage 230 Der Endpunkt3 der Mehrkanal-Befehlsklasse bezieht sich auf Relais1 und Relais2. Es kann überflüssig sein, die Notwendigkeit, Relais1 oder Relais2 einzeln zu steuern. Wenn die Existenz von Endpunkt3 als 0 gesetzt ist, wird der Endpunkt3 der Mehrkanal-Befehlsklasse deaktiviert.
Load 2x 1500W
Device Type On/Off Power Switch
Generic Device Class Binary Switch
Specific Device Class Binary Power Switch
Firmware Version 01.08
Z-Wave Version 03.5f
Certification ID ZC10-14120009
Z-Wave Product Id 0x013c.0x0001.0x0013
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeOn/Off Power Switch