Quickstart

This is a Motor Control Device (C) for XXXQFrequencyName. To run this device please connect it to your mains power supply.

 Tripple Click the Button on the device confirms the inclusion, exclusion and association. After power up it will stay in auto inclusion mode for 4 minutes. To support handling of the device when already installed the external switch can be used for inclusion or exclusion for 3 minutes after power up.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The in-wall Roller Shutter Controller is designed to switch rise/lower roller shutter connected to its terminals using Z-Wave or push buttons directly connected to this Roller Controller. Additionally the device is measuring the power consumption and report it to a controller on request. The metering function is also used to protect the device from overload.

The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of roller shutter. This in-wall Roller Shutter Controller is able to detect position of the Shutter by using the patented power measuring method, so it can be remote controlled not only fully up or down , but also can be adjusted to ex. 30% or 50%. And when manual controlled by push button, the controller also can memorize the position and send the new shutter position to its Z-Wave wireless controller (ex. IP-Gateway). This device is designed for a 3 wire system and needs a neutral wire in the wall box.

Installation

Place the in-wall switch into a wall box and connect the pins as shown in the figure.

Calibration

It is important to carry out a shutter calibration process before you control the shutter to move. Press Z-Wave button over 3 seconds and release before the 6th second, the roller shutter controller will start the shutter calibration process. The process is composed of three continue stages. The shutter move to the TOP in first stage, and move to the BOTTOM in second stage, and move to the TOP again in third stage. Then PAN08 will know the total range of UP and DOWN. During the shutter calibration process, any emergencies happen you can press and release the button to stop the process.

Product Usage

The manual operation of the blindcontrol is using traditional switches with two switched inside. One switch turns the blind in one direction, the other blind turns the blind into the opposite direction. In case the motor is active due to the switching of the external switches all wireless commands are ignored. There is no start/stop function implemented with the external switches but direct control of the movement only.

Reset to factory default

Tripple Click the button on the device to enter inclusion mode. Within 1 second press the button again for 5 seconds until LED is off.

Inclusion

Tripple Click the button on the device confirms inclusion 

Exclusion

Tripple Click the button on the device confirms exclusion

NIF

Tripple Click the button on the device sends out a Node Information Frame.

Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Lifeline

Configuration Parameters

Parameter 1: Watt Meter Report Period

instant power consumption report period
Size: 2 Byte, Default Value: 720

Setting Description
10 - 32767 Time in 5s steps

Parameter 2: KWH Meter Report Period

accumulated power consumption
Size: 2 Byte, Default Value: 6

Setting Description
1 - 32767 Time in 10 minutes steps

Parameter 3: Threshol d of Watt for Load Caution

exceeding the value sends a watt meter report command
Size: 2 Byte, Default Value: 500

Setting Description
10 - 500 Power in 0,01A steps

Parameter 4: Threshol d of KWH for Load Caution

exceeding the value sends a KWh meter report command
Size: 2 Byte, Default Value: 2710

Setting Description

Parameter 5: External switch type


Size: 1 Byte, Default Value: 2

Setting Description
1 One Push button
2 Two Push button

Parameter 6: Level report mode


Size: 1 Byte, Default Value: 2

Setting Description
1 Report destination level 5s
2 Report 10 percent level while running

Technical Data

Dimensions 0.0480000x0.0390000x0.0160000 mm
Weight 40 gr
Hardware Platform ZM5202
EAN 4713698571177
IP Class IP 20
Voltage 230V
Device Type Window Covering Position/Endpoint Aware
Generic Device Class Multilevel Switch
Specific Device Class Motor Control Device (C)
Firmware Version 01.00
Z-Wave Version 03.41
Certification ID ZC08-13070030
Z-Wave Product Id 0x013c.0x0001.0x0006
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeWindow Covering Position/Endpoint Aware